Finger arterial versus intrabrachial pressure and continuous cardiac output during head-up tilt testing in healthy subjects

被引:106
作者
Jellema, WT
Imholz, BPM
vanGoudoever, J
Wesseling, KH
vanLieshout, JJ
机构
[1] UNIV AMSTERDAM,ACAD MED CTR,TNO BIOMED INSTRUMENTAT,NL-1100 DE AMSTERDAM,NETHERLANDS
[2] UNIV AMSTERDAM,ACAD MED CTR,DEPT INTERNAL MED,NL-1100 DE AMSTERDAM,NETHERLANDS
关键词
blood pressure; hypotension; stroke volume; syncope;
D O I
10.1042/cs0910193
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
1. The aims of this study were to determine the clinical feasibility of continuous, non-invasive Finapres recordings as a replacement for intrabrachial pressure during a 30 min head-up tilt, and the reliability of continuous cardiac output computation by pulse contour analysis from the finger arterial versus the brachial waveform. 2. In eight healthy subjects a 30 min 70 degrees passive head-up tilt was performed, Finger arterial (FINAP) and intrabrachial (IAP) pressures were measured simultaneously, Beat-to-beat changes in stroke volume were computed using a pulse contour algorithm. 3. Accuracy (the group-averaged FINAP-IAP difference) and precision (the SD of the difference) of Finapres measurements were 4 and 9 mmHg for systolic blood pressure, -5 and 9 mmHg for mean blood pressure and -5 and 9 mmHg for diastolic blood pressure. 4. The time course of the FINAP-IAP differences during head-up tilt showed a linear trend (P<0.001 for all pressure levels), Averaged for the group, the difference increased 7 mmHg for mean blood pressure, The difference in stroke volume computed from FINAP and IAP was 0.3+/-5% (mean+/-SD), and independent of the duration of the tilt (P>0.05). This difference did not change at low blood pressure levels (0.5 +/- 6%). 5. The qualitative performance of the Finapres allows it to be used in the clinical setting as a monitor of sudden changes in blood pressure induced by a 30 min head-up tilt. Relative changes in stroke volume, as obtained by pulse contour analysis of the finger arterial waveform, closely follow intrabrachial values during long-duration head-up tilt and associated arterial hypotension.
引用
收藏
页码:193 / 200
页数:8
相关论文
共 29 条
[1]   POSTURAL EFFECTS ON MUSCLE NERVE SYMPATHETIC ACTIVITY IN MAN [J].
BURKE, D ;
SUNDLOF, G ;
WALLIN, BG .
JOURNAL OF PHYSIOLOGY-LONDON, 1977, 272 (02) :399-414
[2]   CONTINUOUS NONINVASIVE FINGER BLOOD-PRESSURE DURING CONTROLLED HYPOTENSION - A COMPARISON WITH INTRAARTERIAL PRESSURE [J].
EPSTEIN, RH ;
BARTKOWSKI, RR ;
HUFFNAGLE, S .
ANESTHESIOLOGY, 1991, 75 (05) :796-803
[3]   METHODOLOGY OF HEAD-UP TILT TESTING IN PATIENTS WITH UNEXPLAINED SYNCOPE [J].
FITZPATRICK, AP ;
THEODORAKIS, G ;
VARDAS, P ;
SUTTON, R .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1991, 17 (01) :125-130
[4]   NONINVASIVE BLOOD-PRESSURE MONITORING DURING HEAD-UP TILT USING THE PENAZ PRINCIPLE [J].
FRIEDMAN, DB ;
JENSEN, FB ;
MATZEN, S ;
SECHER, NH .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1990, 34 (07) :519-522
[5]  
Imholz B P, 1991, Clin Auton Res, V1, P43, DOI 10.1007/BF01826057
[6]   NONINVASIVE CONTINUOUS FINGER BLOOD-PRESSURE MEASUREMENT DURING ORTHOSTATIC STRESS COMPARED TO INTRAARTERIAL PRESSURE [J].
IMHOLZ, BPM ;
SETTELS, JJ ;
VANDERMEIRACKER, AH ;
WESSELING, KH ;
WIELING, W .
CARDIOVASCULAR RESEARCH, 1990, 24 (03) :214-221
[7]   CONTINUOUS MEASUREMENT OF CARDIAC-OUTPUT USING PULSE CONTOUR ANALYSIS [J].
IRLBECK, M ;
FORST, H ;
BRIEGEL, J ;
HALLER, M ;
PETER, K .
ANAESTHESIST, 1995, 44 (07) :493-500
[8]   CONTINUOUS CARDIAC-OUTPUT MONITORING BY PULSE CONTOUR DURING CARDIAC-SURGERY [J].
JANSEN, JRC ;
WESSELING, KH ;
SETTELS, JJ ;
SCHREUDER, JJ .
EUROPEAN HEART JOURNAL, 1990, 11 :26-32
[9]   AN ADEQUATE STRATEGY FOR THE THERMODILUTION TECHNIQUE IN PATIENTS DURING MECHANICAL VENTILATION [J].
JANSEN, JRC ;
SCHREUDER, JJ ;
SETTELS, JJ ;
KLOEK, JJ ;
VERSPRILLE, A .
INTENSIVE CARE MEDICINE, 1990, 16 (07) :422-425
[10]   AN ANALYSIS OF THE RELATIONSHIP BETWEEN CENTRAL AORTIC AND PERIPHERAL UPPER LIMB PRESSURE WAVES IN MAN [J].
KARAMANOGLU, M ;
OROURKE, MF ;
AVOLIO, AP ;
KELLY, RP .
EUROPEAN HEART JOURNAL, 1993, 14 (02) :160-167