The accuracy and precision of four infrared aural canal thermometers during cardiac surgery

被引:40
作者
Imamura, M
Matsukawa, T
Ozaki, M
Sessler, DI
Nishiyama, T
Kumazawa, T
机构
[1] Univ Calif San Francisco, Dept Anesthesia & Perioperat Care, San Francisco, CA 94143 USA
[2] Yamanashi Med Univ, Dept Anesthesia, Yamanashi, Japan
[3] Tokyo Womens Med Univ, Dept Anesthesia, Tokyo, Japan
[4] Univ Tokyo, Sch Med, Dept Anesthesia, Tokyo, Japan
[5] Univ Vienna, Ludwig Boltzmann Inst Clin Anesthesia & Intens Ca, A-1010 Vienna, Austria
[6] Univ Vienna, Dept Anesthesia & Gen Intens Care, Outcomes ResTM Grp, A-1010 Vienna, Austria
关键词
anesthesia; surgery; cardiopulmonary bypass; open-heart; temperature; core; tympanic membrane; aural canal;
D O I
10.1111/j.1399-6576.1998.tb05281.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: Four infrared aural canal thermometers are currently available in Japan: Genius(R), Thermoscan(R), Quickthermo(R), and Thermopit(R). We therefore tested the hypothesis that each is sufficiently accurate and precise for clinical use. Methods: For the purpose of this investigation, we considered accuracy to be the mean difference between the test thermometers and the reference thermocouple. Precision was considered to be the standard deviation of the difference between the test and reference values. We evaluated ten patients undergoing cardiopulmonary bypass with moderate hypothermia (approximate to 30 degrees C). Aural canal temperatures were measured in random order with each infrared thermometer, and compared with readings from a thermocouple positioned at the contralateral tympanic membrane. Results: Compared to the thermocouple, the Genius(R) and Thermoscan(R) both had regression slopes >0.85 and correlation coefficients near 0.87; in contrast, slopes of the Quickthermo(R) and Thermopit(R) regressions were 0.68 and 0.53, respectively. The correlation coefficients for each were <0.65. The accuracy (offset, or bias) was near 0 degrees C with both the Genius(R) and Thermoscan(R) thermometers. In contrast, it was 1.1 degrees C with the Quickthermo(R) and a full 2.3 degrees C with the Thermopit(R). The precision (standard deviation) of the measurements, however, was approximate to 0.8 degrees C in each case. Conclusion: We conclude that none of the tested aural canal infrared thermometers was sufficiently accurate and precise for perioperative use.
引用
收藏
页码:1222 / 1226
页数:5
相关论文
共 26 条
[1]   TYMPANIC THERMOMETRY IN SURGERY AND ANESTHESIA [J].
BENZINGER, M .
JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1969, 209 (08) :1207-+
[2]  
BENZINGER T. H., 1959, PROC NATL ACAD SCI, V45, P645, DOI 10.1073/pnas.45.4.645
[3]  
BISSONNETTE B, 1989, ANESTH ANALG, V69, P192
[4]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[5]  
BLOCH EC, 1992, ANESTH ANALG, V74, P486
[6]  
CORK RC, 1983, ANESTH ANALG, V62, P211
[7]   Perioperative maintenance of normothermia reduces the incidence of morbid cardiac events - A randomized clinical trial [J].
Frank, SM ;
Fleisher, LA ;
Breslow, MJ ;
Higgins, MS ;
Olson, KF ;
Kelly, S ;
Beattie, C .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1997, 277 (14) :1127-1134
[8]   MATERNAL PYREXIA ASSOCIATED WITH THE USE OF EPIDURAL ANALGESIA IN LABOR [J].
FUSI, L ;
MARESH, MJA ;
STEER, PJ ;
BEARD, RW .
LANCET, 1989, 1 (8649) :1250-1252
[9]  
GRONERT GA, 1994, MALIGNANT HYPERTHERM, P1075
[10]   Thermal response in acute porcine malignant hyperthermia [J].
Iaizzo, PA ;
Kehler, CH ;
Zink, RS ;
Belani, KG ;
Sessler, DI .
ANESTHESIA AND ANALGESIA, 1996, 82 (04) :782-789