Effects of nitroglycerin on the diagnostic accuracy of electrocardiogram-gated coronary computed tomography angiography

被引:60
作者
Chun, Eun Ju [2 ]
Lee, Whal [1 ]
Choi, Young Hoon [1 ]
Koo, Bon-Kwon [3 ,4 ]
Choi, Sang Il [5 ]
Jae, Hwan Jun [1 ]
Kim, Hyo-Cheol [1 ]
So, Young Ho [1 ]
Chung, Jin Wook [1 ]
Park, Jae Hyung [1 ]
机构
[1] Seoul Natl Univ, Coll Med, Dept Radiol, Inst Radiat Med,Clin Res Inst,Seoul Natl Univ Hos, 28 Yongon Dong, Seoul 110744, South Korea
[2] Seoul Natl Univ, Bundang Hosp, Dept Radiol, Seoul 110744, South Korea
[3] Seoul Natl Univ, Coll Med, Dept Internal Med, Div Cardiol,Cardiovasc Ctr, Seoul 110744, South Korea
[4] Seoul Natl Univ Hosp, Cardiovasc Res Inst, Seoul 110744, South Korea
[5] Seoul Natl Univ, Bundang Hosp, Dept Radiol, Seoul 110744, South Korea
关键词
coronary CT angiography; coronary artery disease; nitroglycerin;
D O I
10.1097/rct.0b013e318059befa
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: To evaluate the effect of nitroglycerin on the diagnostic accuracy of electrocardiogram-gated coronary computed tomography (CT) angiography in patients with suspected coronary artery disease. Methods: Computed tomography angiography was performed on 76 patients using a 16-slice CT scanner. Forty-six patients received a sublingual nitroglycerin I minute before CT scanning (the NTG group), but the other 30 did not (the non-NTG group). No statistically significant differences were evident between these 2 groups in terms of clinical and demographic characteristics. Significant stenosis (>= 50% diameter reduction) as determined by CT was evaluated according to patient-based and segment-based analyses, and results were compared with conventional coronary angiographic findings. In addition, segments of the coronary artery were reclassified by segment luminal size into proximal, mid, and distal segments, and the diagnostic accuracies of the NTG and non-NTG approaches were evaluated in these segments. Results: Differences in heart rate, and systolic and diastolic blood pressures before and after using nitroglycerin were 1.0 +/- 2.4 beats per minute, -8.3 +/- 14.4 mm Hg, and -4.6 +/- 10.6 mm Hg, respectively. Sensitivity, specificity, and positive and negative predictive values in the NTG group were higher than in the non-NTG group by patient-based analysis (P = 0.25) and by segment-based analysis (P < 0.05). In addition, based on the luminal size of each segment, diagnostic accuracy in the NTG group was significantly higher for proximal segments than in the non-NTG group (96.7% vs 89.7%; P < 0.05). Conclusions: The use of nitroglycerin was found to be safe and to improve the diagnostic accuracy of coronary CT angiography for the evaluation of coronary artery disease.
引用
收藏
页码:86 / 92
页数:7
相关论文
共 15 条
[1]   Coronary vasomotor response is related to the angiographic extent of coronary sclerosis in patients with stable angina pectoris [J].
Asselbergs, FW ;
Monnink, SHJ ;
Veeger, NJGM ;
van Boven, AJ ;
van Haelst, PL ;
Jessurun, GAJ ;
van Gilst, WH ;
Tio, RA .
CLINICAL SCIENCE, 2004, 106 (02) :115-120
[2]  
Austen W G, 1975, Circulation, V51, P5
[3]   MAGNITUDE OF DILATATION OF LARGE AND SMALL CORONARY-ARTERIES BY NITROGLYCERIN [J].
FELDMAN, RL ;
PEPINE, CJ ;
CONTI, CR .
CIRCULATION, 1981, 64 (02) :324-333
[4]   ARTERIOGRAPHIC DEMONSTRATION OF CORONARY ARTERY SPASM AND ITS RELEASE AFTER USE OF A VASODILATOR IN A CASE OF ANGINA PECTORIS AND IN EXPERIMENTAL ANIMAL [J].
GENSINI, GG ;
BLACK, A ;
MURADNETTO, S ;
DIGIORGI, S .
ANGIOLOGY, 1962, 13 (12) :550-&
[5]  
Hoffmann U, 2006, J NUCL MED, V47, P797
[6]   Predictive value of 16-slice multidetector spiral computed tomography to detect significant obstructive coronary artery disease in patients at high risk for coronary artery disease - Patient-versus segment-based analysis [J].
Hoffmann, U ;
Moselewski, F ;
Cury, RC ;
Ferencik, M ;
Jang, IK ;
Diaz, LJ ;
Abbara, S ;
Brady, TJ ;
Achenbach, S .
CIRCULATION, 2004, 110 (17) :2638-2643
[7]   Coronary arteries: Retrospectively ECG-gated multi-detector row CT angiography with selective optimization of the image reconstruction window [J].
Kopp, AF ;
Schroeder, S ;
Kuettner, A ;
Heuschmid, M ;
Georg, C ;
Ohnesorge, B ;
Kuzo, R ;
Claussen, CD .
RADIOLOGY, 2001, 221 (03) :683-688
[8]   Diagnostic accuracy of noninvasive coronary imaging using 16-detector slice spiral computed tomography with 188 ms temporal resolution [J].
Kuettner, A ;
Beck, T ;
Drosch, T ;
Kettering, K ;
Heuschmid, M ;
Burgstahler, C ;
Claussen, CD ;
Kopp, AF ;
Schroeder, S .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 45 (01) :123-127
[9]   EVALUATION OF CORONARY VASODILATORS BY CORONARY ARTERIOGRAPHY [J].
LIKOFF, W ;
SEGAL, BL ;
LEHMAN, JS ;
KASPARIAN, H .
AMERICAN JOURNAL OF CARDIOLOGY, 1964, 13 (01) :7-&
[10]   Improved diagnostic accuracy with 16-row multi-slice computed tomography coronary angiography [J].
Mollet, NR ;
Cademartiri, F ;
Krestin, GP ;
McFadden, EP ;
Arampatzis, CA ;
Serruys, PW ;
de Feyter, PJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 45 (01) :128-132