MR renography by semiautomated image analysis: Performance in renal transplant recipients

被引:38
作者
de Priester, JA [1 ]
Kessels, AGH [1 ]
Giele, ELW [1 ]
den Boer, JA [1 ]
Christiaans, MHL [1 ]
Hasman, A [1 ]
van Engelshoven, JMA [1 ]
机构
[1] Univ Hosp, Dept Radiol, Maastricht, Netherlands
关键词
gadolinium; kidney; function; MR studies; magnetic resonance (MR); contrast media;
D O I
10.1002/jmri.1163
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We evaluated a method of semiautomated analysis of dynamic MR image series in renal transplants. Nine patients were studied twice, with an average time interval of 7 days. MR examination consisted of a run of 256 T1-weighted coronal scans (GE; TR/TE/flip: = 11/3.4/60 degrees; slice thickness = 6 mm; temporal resolution = 2 seconds). Gadolinium-DTPA (0.05 mmol/kg) was Injected with an injector pump (5 ml/seconds). MR renographs of the cortex and medulla were obtained by segmentation of the renal transplant and placement of two regions of interest (ROIs) overlying the peripheral and central renal parenchyma. In the first 100 frames of the renographs, analysis of variance (ANOVA) demonstrated significant intraclass correlation coefficients with mean values for the cortex and medulla of 0.47 and 0.59, respectively. We conclude that the procedure is a robust technique that generates meaningful signal curves. (C) 2001 Wiley-Liss, Inc.
引用
收藏
页码:134 / 140
页数:7
相关论文
共 17 条
[1]   USE OF GD-DTPA AND FAST GRADIENT-ECHO AND SPIN-ECHO MR IMAGING TO DEMONSTRATE RENAL-FUNCTION IN THE RABBIT [J].
CARVLIN, MJ ;
ARGER, PH ;
KUNDEL, HL ;
AXEL, L ;
DOUGHERTY, L ;
KASSAB, EA ;
MOORE, B .
RADIOLOGY, 1989, 170 (03) :705-711
[2]   DYNAMIC GD-DTPA - ENHANCED MR IMAGING OF THE KIDNEY - EXPERIMENTAL RESULTS [J].
CHOYKE, PL ;
FRANK, JA ;
GIRTON, ME ;
INSCOE, SW ;
CARVLIN, MJ ;
BLACK, JL ;
AUSTIN, HA ;
DWYER, AJ .
RADIOLOGY, 1989, 170 (03) :713-720
[3]  
de Priester JA, 2000, J MAGN RESON IMAGING, V12, P453, DOI 10.1002/1522-2586(200009)12:3<453::AID-JMRI11>3.0.CO
[4]  
2-Z
[5]  
GUYTON AC, 1991, TXB MED PHYSL, P403
[6]   NORMAL AND HYDRONEPHROTIC KIDNEY - EVALUATION OF RENAL-FUNCTION WITH CONTRAST-ENHANCED MR IMAGING [J].
KIKINIS, R ;
VONSCHULTHESS, GK ;
JAGER, P ;
DURR, R ;
BINO, M ;
KUONI, W ;
KUBLER, O .
RADIOLOGY, 1987, 165 (03) :837-842
[7]   EVALUATION OF ACUTE-RENAL-FAILURE WITH MAGNETIC-RESONANCE-IMAGING USING GRADIENT-ECHO AND GD-DTPA [J].
MUNECHIKA, H ;
SULLIVAN, DC ;
HEDLUND, LW ;
BEAM, CA ;
SOSTMAN, HD ;
HERFKENS, RJ ;
PELC, NJ .
INVESTIGATIVE RADIOLOGY, 1991, 26 (01) :22-27
[8]  
Nakashima R, 1996, Radiat Med, V14, P251
[9]   Physiologic measurements by contrast-enhanced MR imaging: Expectations and limitations [J].
Roberts, TPL .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (01) :82-90
[10]   DIAGNOSIS OF RENAL-ARTERY STENOSIS - FEASIBILITY OF COMBINING MR-ANGIOGRAPHY, MR RENOGRAPHY, AND GADOPENTETATE-BASED MEASUREMENTS OF GLOMERULAR-FILTRATION RATE [J].
ROS, PR ;
GAUGER, J ;
STOUPIS, C ;
BURTON, SS ;
MAO, J ;
WILCOX, C ;
ROSENBERG, EB ;
BRIGGS, RW .