Tumor-line specific pO2 fluctuations in human melanoma xenografts

被引:47
作者
Brurberg, KG
Graff, BA
Olsen, DR
Rofstad, EK [1 ]
机构
[1] Norwegian Radium Hosp, Inst Canc Res, Dept Biophys, Grp Radiat Biol & Tumor Physiol, N-0310 Oslo, Norway
[2] Norwegian Radium Hosp, Inst Canc Res, Ctr Res & Training Radiat Therapy, N-0310 Oslo, Norway
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2004年 / 58卷 / 02期
关键词
acute hypoxia; oxygen tension; pO(2) fluctuations; temporal heterogeneity in pO(2);
D O I
10.1016/j.ijrobp.2003.09.049
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: A large number of studies have demonstrated that tumors are heterogeneous in oxygen tension (pO(2)) and may develop regions with chronically or acutely hypoxic cells during growth. In the present study, it was investigated whether experimental tumors of different lines may sh<ow characteristic pO(2) fluctuation patterns and hence may differ with respect to the kinetics of acute hypoxia. Methods and Materials: A total of 70 xenografted tumors of two human melanoma lines (A-07 and R-18) were included in the study. Tissue pO(2), was measured simultaneously in two positions in each tumor for periods of at least 60 min using a two-channel fiberoptic oxygen-sensing device (OxyLite 2000, Oxford Optronix, Oxford, UK). Results: The mean pO(2), was calculated for each pO(2) trace, and this parameter was significantly greater in A-07 than in R-18 tumors (p <0.000001). Fluctuations in pO(2), around 3, 5, or 10 mm Hg were seen in a large fraction of the tumors of both lines. The pO(2) fluctuation frequency differed among individual traces from 0 to 20/h (A-07) and from 0 to 12/h (R-18) and was significantly greater in A-07 than in R-18 tumors (p = 0.0026). The absolute amplitude of the pO(2) fluctuations ranged from 1 to 16 mm Hg (A-07) and I to 33 rum Hg (R-18) and did not differ between the tumor lines. The relative amplitude was significantly higher in R-18 than in A-07 tumors (p 0.000001). The pO(2) values recorded simultaneously in the same tumor were in general not temporally coordinated. Conclusion: Experimental tumors of different lines may show individual and characteristic pO(2), fluctuation patterns. The pO(2) fluctuations may result in regions with acutely hypoxic cells. The kinetics of the acute hypoxia may differ among tumors of different lines, individual tumors of the same line, and different regions within the same tumor. (C) 2004 Elsevier Inc.
引用
收藏
页码:403 / 409
页数:7
相关论文
共 32 条
  • [1] Fourier analysis of fluctuations of oxygen tension and blood flow in R3230Ac tumors and muscle in rats
    Braun, RD
    Lanzen, JL
    Dewhirst, MW
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 1999, 277 (02): : H551 - H568
  • [2] Comparison of tumor and normal tissue oxygen tension measurements using OxyLite or microelectrodes in rodents
    Braun, RD
    Lanzen, JL
    Snyder, SA
    Dewhirst, MW
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2001, 280 (06): : H2533 - H2544
  • [3] A COMPARISON OF TUMOR AND NORMAL TISSUE MICROVASCULAR HEMATOCRITS AND RED-CELL FLUXES IN A RAT WINDOW CHAMBER MODEL
    BRIZEL, DM
    KLITZMAN, B
    COOK, JM
    EDWARDS, J
    ROSNER, G
    DEWHIRST, MW
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 25 (02): : 269 - 276
  • [4] Brown JM, 1999, CANCER RES, V59, P5863
  • [5] Temporal heterogeneity in oxygen tension in human melanoma xenografts
    Brurberg, KG
    Graff, BA
    Rofstad, EK
    [J]. BRITISH JOURNAL OF CANCER, 2003, 89 (02) : 350 - 356
  • [6] Effects of nicotinamide and carbogen on oxygenation in human tumor xenografts measured with luminescense based fiber-optic probes
    Bussink, J
    Kaanders, JHAM
    Strik, AM
    van der Kogel, AJ
    [J]. RADIOTHERAPY AND ONCOLOGY, 2000, 57 (01) : 21 - 30
  • [7] Cairns RA, 2001, CANCER RES, V61, P8903
  • [8] CHAPLIN DJ, 1987, CANCER RES, V47, P597
  • [9] TEMPORAL HETEROGENEITY IN MICROREGIONAL ERYTHROCYTE FLUX IN EXPERIMENTAL SOLID TUMORS
    CHAPLIN, DJ
    HILL, SA
    [J]. BRITISH JOURNAL OF CANCER, 1995, 71 (06) : 1210 - 1213
  • [10] Measurement of tumor oxygenation: A comparison between polarographic needle electrodes and a time-resolved luminescence-based optical sensor
    Collingridge, DR
    Young, WK
    Vojnovic, B
    Wardman, P
    Lynch, EM
    Hill, SA
    Chaplin, DJ