An endoscopic imaging system for turbine engine pressure sensitive paint measurements

被引:17
作者
Alaruri, S
Bonsett, T
Smith, D
Macri, F
Brewington, A
Wildman, D
机构
[1] Rolls Royce Corp, Indianapolis, IN 46206 USA
[2] Allison Adv Dev Co, Indianapolis, IN 46206 USA
关键词
Pressure sensitive paint measurements;
D O I
10.1016/S0143-8166(01)00049-5
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A fiber-optic endoscopic imaging system for mapping the surface pressure of turbine engine parts coated with pressure sensitive paint has been developed. Fluorescence intensity measurements collected from a ruthenium bathophenanthroline pressure sensitive paint sample tinder different pressure and temperature settings are presented. Moreover, a simple analysis for the errors resulting from the shift in the pressure sensitive paint fluorescence intensity due to temperature artifacts is given. (C) 2001 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:277 / 287
页数:11
相关论文
共 14 条
[1]  
CAMPELL B, 1997, THESIS PURDUE U W LA
[2]   Method for depixelating micro-endoscopic images [J].
Dickens, MM ;
Houlne, MP ;
Mitra, S ;
Bornhop, DJ .
OPTICAL ENGINEERING, 1999, 38 (11) :1836-1842
[3]  
ENGLER R, 1997, AGARD PEP S ADV NON
[4]  
Guenther W. C., 1973, CONCEPTS STAT INFERE
[5]  
*ISSI, ILL SOURC
[6]  
JORDAN J, 1999, P 45 INT INSTR S ALB
[7]   LUMINESCENT BAROMETRY IN WIND TUNNELS [J].
KAVANDI, J ;
CALLIS, J ;
GOUTERMAN, M ;
KHALIL, G ;
WRIGHT, D ;
GREEN, E ;
BURNS, D ;
MCLACHLAN, B .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1990, 61 (11) :3340-3347
[8]  
Kondratev VN, 1964, Chemical Kinetics of Gas Reactions.
[9]  
LIU T, 1997, 35 AER SCI M EXH 9 1
[10]   Tailoring of sol-gel films for optical sensing of oxygen in gas and aqueous phase [J].
McDonagh, C ;
MacCraith, BD ;
McEvoy, AK .
ANALYTICAL CHEMISTRY, 1998, 70 (01) :45-50