Use of semipermeable membrane devices (SPMDs) -: Determination of bioavailable, organic, waterborne contaminants in the industrial region of Bitterfeld, Saxony-Anhalt, Germany

被引:48
作者
Vrana, B
Paschke, A
Popp, P
Schüürmann, G
机构
[1] UFZ Helmholtz Ctr Environm Res, Dept Chem Ecotoxicol, D-04318 Leipzig, Germany
[2] UFZ Helmholtz Ctr Environm Res, Dept Analyt Chem, D-04318 Leipzig, Germany
关键词
bioavailability; monitoring; organochlorine pesticides; passive sampling; persistent organic pollutants; priority pollutants; polyaromatic hydrocarbons; polychlorinated biphenyls; semipermeable membrane devices (SPMDs); water contamination;
D O I
10.1007/BF02987292
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Triolein-containing semipermeable membrane devices (SPMDs) were employed as passive samplers to provide data on the bioavailable fraction of organic, waterborne, organochlorine pesticides (OCPs), polychlorinated biphenyls (PCBs) and poly nuclear aromatic hydrocarbons (PAHs) in streams flowing through a highly polluted industrial area of Bitterfeld in Saxony-Anhalt, Germany. The contamination of the region with organic pollutants originates in wastewater effluents from the chemical industry, from over one-hundred years of lignite exploitation, and from chemical waste dumps. The main objective was to characterise time-integrated levels of dissolved contaminants, to use them for identification of spatial trends of contamination, and their relationship to potential pollution sources. SPMDs were deployed for 43 days in the summer of 1998 at four sampling sites. The total concentration of pollutants at sampling sites was found to range from a low of 0.8 mug/SPMD to 25 mug/ SPMD for PAHs, and from 0.4 mug/SPMD to 22 mug/SPMD for OCPs, respectively. None of the selected PCB congeners was present at quantifiable levels at any sampling site. A point source of water pollution with OCPs and PAHs was identified in the river system considering the total contaminant concentrations and the distribution of individual compounds accumulated by SPMDs at different sampling sites. SPMD-data was also used to estimate average ambient water concentrations of the contaminants at each field site and compared with concentrations measured in bulk water extracts. The truly dissolved or bioavailable portion of contaminants at different sampling sites ranged from 4% to 86% for the PAHs, and from 8% to 18% for the OCPs included in the estimation. The fraction of individual compounds found in the freely dissolved form can be attributed to the range of their hydrophobicity. In comparison with liquid/liquid extraction of water samples, the SPMD method is more suitable for an assessment of the background concentrations of hydrophobic organic contaminants because of substantially lower method quantification limits. Moreover, contaminant residues sequestered by the SPMDs represent an estimation of the dissolved or readily bioavailable concentration of hydrophobic contaminants in water, which is not provided by most analytical approaches.
引用
收藏
页码:27 / 34
页数:8
相关论文
共 22 条
[1]  
[Anonymous], TECHNIQUES AQUATIC T
[2]   Semi-permeable membrane devices (SPMDs) for monitoring organic contaminants in the Otonabee River, Ontario [J].
Bennett, ER ;
Metcalfe, TL ;
Metcalfe, CD .
CHEMOSPHERE, 1996, 33 (03) :363-375
[3]   Calibrating the uptake kinetics of semipermeable membrane devices using exposure standards [J].
Booij, K ;
Sleiderink, HM ;
Smedes, F .
ENVIRONMENTAL TOXICOLOGY AND CHEMISTRY, 1998, 17 (07) :1236-1245
[4]  
ELLIS GS, 1995, ENVIRON TOXICOL CHEM, V14, P1875, DOI [10.1897/1552-8618(1995)14[1875:EOLSMD]2.0.CO
[5]  
2, 10.1002/etc.5620141109]
[6]   Three-compartment model for contaminant accumulation by semipermeable membrane devices [J].
Gale, RW .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1998, 32 (15) :2292-2300
[7]   Lipid-filled semipermeable membrane devices and mussels as samplers of organochlorine compounds in lake water [J].
Herve, S ;
Prest, HF ;
Heinonen, P ;
Hyotylainen, T ;
Koistinen, J ;
Paasivirta, J .
ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 1995, 2 (01) :24-30
[8]   SEMIPERMEABLE-MEMBRANE DEVICES CONTAINING MODEL LIPID - A NEW APPROACH TO MONITORING THE BIOAVAILABILITY OF LIPOPHILIC CONTAMINANTS AND ESTIMATING THEIR BIOCONCENTRATION POTENTIAL [J].
HUCKINS, JN ;
TUBERGEN, MW ;
MANUWEERA, GK .
CHEMOSPHERE, 1990, 20 (05) :533-552
[9]   Determination of uptake kinetics (Sampling rates) by lipid-containing semipermeable membrane devices (SPMDs) for polycyclic aromatic hydrocarbons (PAHs) in water [J].
Huckins, JN ;
Petty, JD ;
Orazio, CE ;
Lebo, JA ;
Clark, RC ;
Gibson, VL ;
Gala, WR ;
Echols, KR .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1999, 33 (21) :3918-3923
[10]   LIPID-CONTAINING SEMIPERMEABLE-MEMBRANE DEVICES FOR MONITORING ORGANIC CONTAMINANTS IN WATER [J].
HUCKINS, JN ;
MANUWEERA, GK ;
PETTY, JD ;
MACKAY, D ;
LEBO, JA .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1993, 27 (12) :2489-2496