Influence of the red blood cell preparation method on the efficacy of a leukocyte reduction filter

被引:14
作者
Alcorta, I
Pereira, A
Sanz, C
Terol, MJ
Ordinas, A
机构
[1] Serv. of Hemotherapy and Hemostasis, Hospital Clinico, Barcelona
[2] Serv. of Hemotherapy and Hemostasis, Hospital Clinico, E-08036 Barcelona
关键词
BEDSIDE FILTER; DEPLETED BLOOD; WHITE; FILTRATION; SYSTEMS;
D O I
10.1046/j.1423-0410.1996.7120078.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The performance of a leukocyte reduction bedside filter with different types of RBC concentrates was analyzed. Three types of RBCs were prepared: buffy-coat-depleted RBCs suspended in saline-adenine-glucose-mannitol (SAGM)additive solution (BC-RBCs; n = 20), RBCs suspended in SAGM-additive solution without buffy coat removal. (SAGM-RBCs; n = 20), and RBCs drawn in CPDA-1 conservative solution and processed for component preparation by the platelet-rich plasma method (CPDA-RBCs; n = 20). The units were filtered within 8 h of collection. One filter was used for every 2 units. High numbers of residual WBCs were found even in the units filtered first. Filtration of CPDA-RBCs resulted in a higher residual WBC content than SAGM-RBCs or BC-RBCs (p = 0.0032 and p = 0.0002, respectively). The filter performance strikingly decreased when the WBC load per filter exceeded 4 x 10(9) or the platelet load was less than 100 x 10(9). We conclude that filter performance varies with the WBC and platelet content of the RBC concentrates. Under the experimental conditions assayed in this study CPDA-RBCs are the least appropriate ones to be used for bedside leukocyte reduction.
引用
收藏
页码:78 / 83
页数:6
相关论文
共 11 条
[1]   PREPARATION OF WHITE CELL-DEPLETED BLOOD - COMPARISON OF 2 BEDSIDE FILTER SYSTEMS [J].
BOCK, M ;
WAGNER, M ;
KNUPPEL, W ;
RIEDNER, C ;
PACHMANN, U ;
HEIM, MU ;
MEMPEL, W .
TRANSFUSION, 1990, 30 (01) :26-29
[2]   LEUKOCYTE DEPLETION FILTERS - A COMPARISON OF EFFICIENCY [J].
BODENSTEINER, DC .
AMERICAN JOURNAL OF HEMATOLOGY, 1990, 35 (03) :184-186
[3]  
European Committee (Partial Agreement) on Blood Transfusion (CD P TS), 1992, GUID PREP US QUAL AS
[4]   ACCURATE QUANTITATION OF THE LOW NUMBER OF WHITE CELLS IN WHITE CELL-DEPLETED BLOOD COMPONENTS [J].
KAO, KJ ;
SCORNIK, JC .
TRANSFUSION, 1989, 29 (09) :774-777
[5]  
KLEIN HG, 1994, STANDARDS BLOOD BANK, P16
[6]   LEUKOCYTE REDUCTION IN BLOOD COMPONENT THERAPY [J].
LANE, TA ;
ANDERSON, KC ;
GOODNOUGH, LT ;
KURTZ, S ;
MOROFF, G ;
PISCIOTTO, PT ;
SAYERS, M ;
SILBERSTEIN, LE .
ANNALS OF INTERNAL MEDICINE, 1992, 117 (02) :151-162
[7]   INADEQUATE WHITE CELL-REDUCTION BY BEDSIDE FILTRATION OF RED-CELL CONCENTRATES [J].
LEDENT, E ;
BERLIN, G .
TRANSFUSION, 1994, 34 (09) :765-768
[8]   PLATELET CONCENTRATES STORED IN PLASMA FOR 72 HOURS AT 22-DEGREES-C PREPARED FROM BUFFYCOATS OF CITRATE PHOSPHATE DEXTROSE BLOOD COLLECTED IN A QUADRUPLE-BAG SALINE ADENINE GLUCOSE MANNITOL SYSTEM [J].
PIETERSZ, RNI ;
LOOS, JA ;
REESINK, HW .
VOX SANGUINIS, 1985, 49 (02) :81-85
[9]   PREPARATION OF WHITE CELL-REDUCED RED-CELLS BY FILTRATION - COMPARISON OF A BEDSIDE FILTER AND 2 BLOOD-BANK FILTER SYSTEMS [J].
SPROGOEJAKOBSEN, U ;
SAETRE, AM ;
GEORGSEN, J .
TRANSFUSION, 1995, 35 (05) :421-426
[10]  
STENEKER I, 1992, TRANSFUSION, V32, P42