Differences in exhaled breath condensate pH measurements between samples obtained with two commercial devices

被引:54
作者
Prieto, L.
Ferrer, A.
Palop, J.
Domenech, J.
Llusar, R.
Rojas, R.
机构
[1] Hosp Univ Dr Peset, Secc Alergol, Valencia 46017, Spain
[2] Hosp Univ Dr Peset, Serv Neumol, Valencia 46017, Spain
关键词
exhaled breath condensate; pH; collection device; airway inflammation; asthma; allergic rhinitis;
D O I
10.1016/j.rmed.2007.02.023
中图分类号
R5 [内科学];
学科分类号
1002 [临床医学]; 100201 [内科学];
摘要
Background: The objective of this study was to determine differences in EBC pH between samples obtained by RTube and EcoScreen, and to identify the effect of storage at -80 degrees C on the pH values. Methods: Twenty-three nonsmoking subjects with asthma or allergic rhinitis or without respiratory disease performed two sequential exhaled, breath condensate (EBC) collections, using the RTube collection system and the EcoScreen condenser. EBC pH was measured immediately after collection and after storage at -80 degrees C for 8 weeks, without deaeration and repeated following deaeration with Argon. Results: In EBC samples without deaeration, the EcoScreen pH values were significantly higher than the RTube pH values (mean difference, 0.32; 95% CI, 0.21-0.44, P < 0.0001). In deaerated EBC samples, the EcoScreen pH values were also significantly higher than the RTube pH values (mean difference, 0. 12; 95% CI, 0.01-0.25, P = 0.04). For both EBC collection systems, storage for 8 weeks had a significant influence on pH of nondeaerated samples. Conclusions: The present study demonstrates that EBC pH value is dependent on the collection device used and that the storage for 8 weeks had a significant influence on the pH of samples analyzed without deaeration. (c) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1715 / 1720
页数:6
相关论文
共 18 条
[1]
[Anonymous], 1987, AM REV RESPIR DIS, V136, P1285
[2]
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]
Reproducibility of exhaled breath condensate pH in chronic obstructive pulmonary disease [J].
Borrill, Z ;
Starkey, C ;
Vestbo, J ;
Singh, D .
EUROPEAN RESPIRATORY JOURNAL, 2005, 25 (02) :269-274
[4]
The effects of volatile salivary acids and bases on exhaled breath condensate pH [J].
Effros, RM ;
Casaburi, R ;
Su, J ;
Dunning, M ;
Torday, J ;
Biller, J ;
Shaker, R .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2006, 173 (04) :386-392
[5]
Exhaled breath condensate acidification in acute lung injury [J].
Gessner, C ;
Hammerschmidt, S ;
Kuhn, H ;
Seyfarth, HA ;
Sack, U ;
Engelmann, L ;
Schauer, J ;
Wirtz, H .
RESPIRATORY MEDICINE, 2003, 97 (11) :1188-1194
[6]
Exhaled breath condensate: An evolving tool for noninvasive evaluation of lung disease [J].
Hunt, J .
JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 2002, 110 (01) :28-34
[7]
Endogenous airway acidification - Implications for asthma pathophysiology [J].
Hunt, JF ;
Fang, KZ ;
Malik, R ;
Snyder, A ;
Malhotra, N ;
Platts-Mills, TAE ;
Gaston, B .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2000, 161 (03) :694-699
[8]
pH in expired breath condensate of patients with inflammatory airway diseases [J].
Kostikas, K ;
Papatheodorou, G ;
Ganas, K ;
Psathakis, K ;
Panagou, P ;
Loukides, S .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2002, 165 (10) :1364-1370
[9]
Clinical and technical factors affecting pH and other biomarkers in exhaled breath condensate [J].
Leung, TF ;
Li, CY ;
Yung, E ;
Liu, EKH ;
Lam, CWK ;
Wong, GWK .
PEDIATRIC PULMONOLOGY, 2006, 41 (01) :87-94
[10]
Effects of breathing pattern and inspired air conditions on breath condensate volume, pH, nitrite, and protein concentrations [J].
McCafferty, JB ;
Bradshaw, TA ;
Tate, S ;
Greening, AP ;
Innes, JA .
THORAX, 2004, 59 (08) :694-698