The use of Permeation Liquid Membrane (PLM) as an analytical tool for trace metal speciation studies in natural waters

被引:6
作者
Parthasarathy, N [1 ]
Pelletier, M [1 ]
Buffle, J [1 ]
机构
[1] Univ Geneva, Dept Analyt Chem Sci 2, CH-1211 Geneva 4, Switzerland
来源
JOURNAL DE PHYSIQUE IV | 2003年 / 107卷
关键词
D O I
10.1051/jp4:20030472
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Permeation liquid membrane (PLM) based on liquid-liquid extraction principles is an emerging analytical tool for making in situ trace metal speciation measurements. A PLM comprising didecyl 1,10 diaza crown ether-lauric acid in phenylhexane/toluene has been developed for measuring free metal ions (e.g. Cu, Pb, Cd and Zn) concentration under natural water conditions. The capability of PLM for making speciation studies has been demonstrated using synthetic and natural ligands. Application of in situ preconcentration of trace metals in diverse waters using specially designed hollow fibre PLM are reported.
引用
收藏
页码:1021 / 1024
页数:4
相关论文
共 4 条
[1]   SEPARATION OF METAL SPECIES BY SUPPORTED LIQUID MEMBRANES [J].
DANESI, PR .
SEPARATION SCIENCE AND TECHNOLOGY, 1984, 19 (11-1) :857-894
[2]   Hollow fiber based supported liquid membrane: a novel analytical system for trace metal analysis [J].
Parthasarathy, N ;
Pelletier, M ;
Buffle, J .
ANALYTICA CHIMICA ACTA, 1997, 350 (1-2) :183-195
[3]  
Parthasarathy N, 1999, CHEM ANAL-WARSAW, V44, P455
[4]  
Parthasarathy N., 2000, SITU MONITORING AQUA, P407