Environmental assessment of biogas co- or tri-generation units by life cycle analysis methodology

被引:60
作者
Chevalier, C [1 ]
Meunier, F [1 ]
机构
[1] Cnam IFFI, Lab Froid, EA 21, F-75141 Paris, France
关键词
biogas; co-generation; tri-generation; LCA (life cycle analysis);
D O I
10.1016/j.applthermaleng.2005.03.011
中图分类号
O414.1 [热力学];
学科分类号
摘要
A life cycle analysis performed on biogas co- or tri-generation units shows that the environmental impact depends on the fraction of heat (or cold) used, the distance for crops collection, the efficiencies of the unit and on the NOx emissions. A high efficiency unit (eta(el) = 0.4 and eta(g) = 0.8) and low NOx content (80 mg/N m(3)) based on 20 km crops collection will save CO2 emissions and act in a CO2 sink resulting in one of the very few technologies capable of reducing atmospheric CO2 concentration. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:3025 / 3041
页数:17
相关论文
共 13 条
[1]  
*COM, 97599 COM
[2]  
EDELMANN W, ECOLOGIC ENERGETIC E
[3]  
FREUND P, 1998, POW GEN 98 C MIL JUN
[4]  
FRISCHKNECHT R, 1993, OKO INVENTARE ENERGI
[5]  
Goedkoop M., 2000, Manual for Designers
[6]   A PROPOSAL FOR THE DEFINITION OF RESOURCE EQUIVALENCY FACTORS FOR USE IN PRODUCT LIFE-CYCLE ASSESSMENT [J].
GUINEE, JB ;
HEIJUNGS, R .
ENVIRONMENTAL TOXICOLOGY AND CHEMISTRY, 1995, 14 (05) :917-925
[7]  
Heijungs R., 1992, Environmental life cycle assessment of products: guide and backgrounds
[8]  
MANN MK, 2002, P SUST ENG, P83
[9]   Co- and tri-generation contribution to climate change control [J].
Meunier, F .
APPLIED THERMAL ENGINEERING, 2002, 22 (06) :703-718
[10]   Mini- and micro-gas turbines for combined heat and power [J].
Pilavachi, PA .
APPLIED THERMAL ENGINEERING, 2002, 22 (18) :2003-2014