Cemented tibial component fixation performs better than cementless fixation -: A randomized radiostereometric study comparing porous-coated, hydroxyapatite-coated and cemented tibial components over 5 years

被引:91
作者
Carlsson, Å
Björkman, A
Besjakov, J
Önsten, I
机构
[1] Malmo Univ Hosp, Dept Orthoped, SE-20502 Malmo, Sweden
[2] Malmo Univ Hosp, Dept Diagnost Radiol, SE-20502 Malmo, Sweden
关键词
D O I
10.1080/00016470510030832
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background The question whether the tibial component of a total knee arthroplasty should be fixed to bone with or without bone cement has not yet been definitely answered. We studied movements between the tibial component and bone by radiostereometry (RSA) in total knee replacement (TKR) for 3 different types of fixation: cemented fixation (C-F), uncemented porous fixation (UC-F) and uncemented porous hydroxyapatite fixation (UCHA-F). Patients 116 patients with osteoarthrosis, who had 146 TKRs, were included in 2 randomized series. The first series included 86 unilateral TKRs stratified into I of the 3 types of fixation. The second series included 30 patients who had simultaneous bilateral TKR surgery, and who were stratified into 3 subgroups of pairwise comparisons of the 3 types of fixation. Results After 5 years 2 knees had been revised, neither of which were due to loosening. 1 UCHA-F knee in the unilateral series showed a large and continuous migration and a poor clinical result, and is a pending failure. The C-F knees rotated and migrated less than UC-F and UCHA-F knees over 5 years. UCHA-F migrated less than UC-F after 1 year. Interpretation Cementing of the tibial component offers more stable bone-implant contact for 5 years compared to uncemented fixation. When using uncemented components, however, there is evidence that augmenting a porous surface with hydroxyapatite may mean less motion between implant and bone after the initial postoperative year.
引用
收藏
页码:362 / 369
页数:8
相关论文
共 9 条
[1]  
BLOEBAUM RD, 1994, CLIN ORTHOP RELAT R, P19
[2]  
EWALD FC, 1989, CLIN ORTHOP RELAT R, P9
[3]  
HOLM S, 1979, SCAND J STAT, V6, P65
[4]  
INSALL JN, 1989, CLIN ORTHOP RELAT R, P13
[5]   CHRONIC LATERAL INSTABILITY OF THE ANKLE - ROENTGEN STEREOPHOTOGRAMMETRY OF TALAR POSITION [J].
LOFVENBERG, R ;
KARRHOLM, J ;
SELVIK, G ;
HANSSON, LI ;
AHLGREN, O .
ACTA ORTHOPAEDICA SCANDINAVICA, 1989, 60 (01) :34-39
[6]   Severe osteolysis after third-body wear due to hydroxyapatite particles from acetabular cup coating [J].
Morscher, EW ;
Hefti, A ;
Aebi, U .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1998, 80B (02) :267-272
[7]   Hydroxyapatite coating versus cemented fixation of the tibial component in total knee arthroplasty -: Prospective randomized comparison of hydroxyapatite-coated and cemented tibial components with 5-year follow-up using radiostereometry [J].
Nilsson, KG ;
Kärrholm, J ;
Carlsson, L ;
Dalén, T .
JOURNAL OF ARTHROPLASTY, 1999, 14 (01) :9-20
[8]   Hydroxyapatite augmentation of the porous coating improves fixation of tibial components -: A randomised RSA study in 116 patients [J].
Önsten, I ;
Nordqvist, A ;
Carlsson, ÅS ;
Besjakov, J ;
Shott, S .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1998, 80B (03) :417-425
[9]   Tibial component fixation in porous- and hydroxyapatite-coated total knee arthroplasty -: A radiostereometric evaluation of migration and inducible displacement after 5 years [J].
Regnér, L ;
Carlsson, L ;
Kärrholm, J ;
Herberts, P .
JOURNAL OF ARTHROPLASTY, 2000, 15 (06) :681-689