摘要
We compare the benefits of spatial and spectral priors in near-infrared diffuse tomography image reconstruction. Although previous studies that incorporated anatomical spatial priors have shown improvement in algorithm convergence and resolution, our results indicate that functional parameter quantification by this approach can be suboptimal. The incorporation of a priori spectral information significantly improves the accuracy observed in recovered images. Specifically, phantom results show that the maximum total hemoglobin concentration ([Hb(T)]) in a region of heterogeneity reached 91% of the true value compared to 63% using spatial priors. The combination of both priors produced results accurate to 98% of the true [Hb(T)]. When both spatial and spectral priors were applied in a healthy volunteer, glandular tissue showed a higher [Hb(T)], water fraction, and scattering power compared to adipose tissue. (c) 2005 Optical Society of America.
引用
收藏
页码:1968 / 1970
页数:3
相关论文
共 10 条
[1]   Magnetic resonance-guided near-infrared tomography of the breast [J].
Brooksby, B ;
Jiang, SD ;
Dehghani, H ;
Pogue, BW ;
Paulsen, KD ;
Kogel, C ;
Doyley, M ;
Weaver, JB ;
Poplack, SP .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2004, 75 (12) :5262-5270
[2]  
BROOKSBY B, IN PRESS J BIOMED OP
[3]   Uniqueness and wavelength optimization in continuous-wave multispectral diffuse optical tomography [J].
Corlu, A ;
Durduran, T ;
Choe, R ;
Schweiger, M ;
Hillman, EMC ;
Arridge, SR ;
Yodh, AG .
OPTICS LETTERS, 2003, 28 (23) :2339-2341
[4]   Diffuse optical tomography with physiological and spatial a priori constraints [J].
Intes, X ;
Maloux, C ;
Guven, M ;
Yazici, B ;
Chance, B .
PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (12) :N155-N163
[5]   Reconstructing chromosphere concentration images directly by continuous-wave diffuse optical tomography [J].
Li, A ;
Zhang, Q ;
Culver, JP ;
Miller, EL ;
Boas, DA .
OPTICS LETTERS, 2004, 29 (03) :256-258
[6]  
LI A, 2005, THESIS TUFTS U
[7]   MRI-guided diffuse optical spectroscopy of malignant and benign breast lesions [J].
Ntziachristos, V ;
Yodh, AG ;
Schnall, MD ;
Chance, B .
NEOPLASIA, 2002, 4 (04) :347-354
[8]   Enhanced frequency-domain optical image reconstruction in tissues through total-variation minimization [J].
Paulsen, KD ;
Jiang, HB .
APPLIED OPTICS, 1996, 35 (19) :3447-3458
[9]   Optical tomographic reconstruction in a complex head model using a priori region boundary information [J].
Schweiger, M ;
Arridge, SR .
PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (11) :2703-2721
[10]   Spectrally constrained chromophore and scattering near-infrared tomography provides quantitative and robust reconstruction [J].
Srinivasan, S ;
Pogue, BW ;
Jiang, SD ;
Dehghani, H ;
Paulsen, KD .
APPLIED OPTICS, 2005, 44 (10) :1858-1869