In-field-of-view thermal image calibration system for medical thermography applications

被引:26
作者
Simpson, R. C. [1 ]
McEvoy, H. C. [1 ]
Machin, G. [1 ]
Howell, K. [2 ]
Naeem, M. [2 ]
Plassmann, P. [3 ]
Ring, F. [3 ]
Campbell, P. [4 ]
Song, C. [4 ]
Tavener, J. [5 ]
Ridley, I. [6 ]
机构
[1] Natl Phys Lab, Teddington TW11 0LW, Middx, England
[2] Royal Free Hosp, London NW3 2QG, England
[3] Univ Glamorgan, Pontypridd CF37 1DL, M Glam, Wales
[4] Univ Dundee, Dundee, Scotland
[5] Isothermal Technol Ltd, Southport, Merseyside, England
[6] Land Instruments, Dronfield, England
关键词
ethylene carbonate; fixed point; gGallium; gallium-zinc; thermal image;
D O I
10.1007/s10765-008-0393-1
中图分类号
O414.1 [热力学];
学科分类号
摘要
Medical thermography has become ever more accessible to hospitals, medical research, and clinical centers with the new generation of thermal cameras, which are easier to use and lower in cost. Some diagnostic techniques using thermal cameras are now regarded as standardized, such as the cold challenge test for Raynaud's phenomenon. The future for medical thermography appears to be improved accuracy, standardization, and establishment as a mainstream medical imaging methodology. Medical thermography standardization, quantitative measurements, image comparison, and multi-center research trials all require thermal cameras to provide a demonstrably traceable, accurate, and reliable temperature output. To this end, the National Physical Laboratory (NPL) has developed a multi-fixed-point source that serves as an in-image calibration system, thereby providing a reliable means for radiometric image validation. An in-field-of-view fixed-point validation system for thermal imaging has successfully been developed, tested, and validated at NPL and has undergone field trials at three clinical centers in the UK. The sources use the phase change plateaux of gallium-zinc eutectic, gallium, and ethylene carbonate. The fixed-point sources have an estimated cavity emissivity of greater than 0.998, a plateau longevity of nominally 3 h at ambient conditions, a stability of 0.1 degrees C, or better, over that period, a repeatability of 0.1 degrees C or better, and an estimated temperature uncertainty of +/- 0.4 degrees C (k = 2). In this article, the source specifications and design as well as testing, validation, and field trial results are described in detail.
引用
收藏
页码:1123 / 1130
页数:8
相关论文
共 4 条
[1]
A low-temperature blackbody reference source to -40°C [J].
Chu, B ;
Machin, G .
MEASUREMENT SCIENCE AND TECHNOLOGY, 1999, 10 (01) :1-6
[2]
Tympanic thermometer performance validation by use of a body-temperature fixed point blackbody [J].
Machin, G ;
Simpson, R .
THERMOSENSE XXV, 2003, 5073 :51-57
[3]
Simpson R., 2006, Journal of Medical Engineering & Technology, V30, P212, DOI 10.1080/03091900600711530
[4]
ZICKOVIC D, 2003, J THERM ANAL CALORIM, V74, P85, DOI DOI 10.1023/A:1026373602352