Effect of breathing on the detection of in vivo simulated pulmonary nodules by spiral CT

被引:5
作者
Coakley, FV
Cohen, MD
Johnson, MS
Gonin, R
Hanna, MP
机构
[1] Indiana Univ, James Whitcomb Riley Hosp Children, Med Ctr, Dept Radiol, Indianapolis, IN 46223 USA
[2] Indiana Univ, James Whitcomb Riley Hosp Children, Med Ctr, Dept Biostat, Indianapolis, IN 46223 USA
关键词
D O I
10.1016/S0009-9260(98)80170-0
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To determine the effect of breathing on the detection of small dense pulmonary nodules of threshold conspicuity by spiral computed tomography (SCT). Materials and Methods: Forty pulmonary nodules of high density were created by endobronchial deployment of 2 and 4 mm diameter beads in the peripheral airways of five anaesthetized dogs. SCT was performed during induced breath-hold and quiet breathing, using 5 mm collimation, pitch 2 and reconstruction of contiguous 5 mm slices. Scans were reviewed by six radiologists, Detection rates were measured as the number of nodules seen by at least one reader. The data was modelled using ordinal logistic regression for repeated measures, and the Wald Chi-square statistic used to test if there was a breath-hold vs. breathing effect on reader confidence level. Results: There was no difference in detection rates for breath-hold vs. breathing SCT (28 vs. 25, respectively; P = 0.48), This was also true when only the 2 mm nodules (n = 24) were considered (12 vs. 11, respectively; P = 0.77). Reader confidence level was significantly higher for breath-hold vs. breathing SCT (Wald Chi-square statistic with 6 degrees of freedom = 19.0; P = 0.0041). Conclusion: SCT can be performed during quiet breathing without a significant reduction the overall detection rate for small dense pulmonary nodules, though reader diagnostic confidence level is reduced.
引用
收藏
页码:506 / 509
页数:4
相关论文
共 21 条
[1]   EFFECTS OF BIOLOGICAL MOTION ON CT RESOLUTION [J].
ALFIDI, RJ ;
MACINTYRE, WJ ;
HAAGA, JR .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1976, 127 (01) :11-15
[2]   PULMONARY NODULES - EFFECT OF INCREASED DATA SAMPLING ON DETECTION WITH SPIRAL CT AND CONFIDENCE IN DIAGNOSIS [J].
BUCKLEY, JA ;
SCOTT, WW ;
SIEGELMAN, SS ;
KUHLMAN, JE ;
URBAN, BA ;
BLUEMKE, DA ;
FISHMAN, EK .
RADIOLOGY, 1995, 196 (02) :395-400
[3]   Detection of pulmonary metastases with pathological correlation: effect of breathing on the accuracy of spiral CT [J].
Coakley, FV ;
Cohen, MD ;
Waters, DJ ;
Davis, MM ;
Karmazyn, B ;
Gonin, R ;
Hanna, MP .
PEDIATRIC RADIOLOGY, 1997, 27 (07) :576-579
[4]  
COAKLEY FV, 1996, RADIOLOGY, V201, P163
[5]  
COHEN MD, 1992, IMAGING CHILDREN CAN
[6]   COMPARISON OF SPIRAL-ACQUISITION COMPUTED-TOMOGRAPHY AND CONVENTIONAL COMPUTED-TOMOGRAPHY IN THE ASSESSMENT OF PULMONARY METASTATIC DISEASE [J].
COLLIE, DA ;
WRIGHT, AR ;
WILLIAMS, JR ;
HASHEMIMALAYERI, B ;
STEVENSON, AJM ;
TURNBULL, CM .
BRITISH JOURNAL OF RADIOLOGY, 1994, 67 (797) :436-444
[7]   PULMONARY NODULE - EVALUATION WITH SPIRAL VOLUMETRIC CT [J].
COSTELLO, P ;
ANDERSON, W ;
BLUME, D .
RADIOLOGY, 1991, 179 (03) :875-876
[8]  
CROW J, 1981, CANCER, V47, P2595, DOI 10.1002/1097-0142(19810601)47:11<2595::AID-CNCR2820471114>3.0.CO
[9]  
2-Q
[10]  
DAVIS SD, 1991, RADIOLOGY, V180, P1