Enzyme flow immunoassay using a Protein G column for the screening of triazine herbicides in surface and waste water

被引:19
作者
Bjarnason, B
Chimuka, L
Önnerfjord, P
Eremin, SA
Jönsson, JÄ
Johansson, G
Emnéus, J
机构
[1] Lund Univ, Dept Analyt Chem, S-22100 Lund, Sweden
[2] Moscow MV Lomonosov State Univ, Fac Chem, Moscow 119899, Russia
关键词
enzyme flow immunoassay; simazine; triazines; pesticides; horse radish peroxidase; Protein G; supported liquid membrane; surface water; waste water;
D O I
10.1016/S0003-2670(00)00842-4
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A method for screening of triazine herbicides in surface and waste water is presented. The method is based on an enzyme flow immunoassay (EFIA) for the detection of the free fraction of a horse radish peroxidase (HRP)-labelled antigen (tracer). This was accomplished by trapping the bound tracer fraction in a Protein G column, allowing the residual free tracer fraction to pass and be detected spectrophotometrically after incubation with an enzyme substrate. As compared with detecting the bound tracer fraction this reduces the regeneration requirements of the Protein G column used for capturing the bound fraction and, therefore, reduces assay time. A polyclonal antibody directed against simazine showed no reactivity towards tracers that were thiopropionic acid derivatives of atrazine, simazine and terbutylazine. It had good sensitivity towards tracers using derivatives of 2-chloro-4,6-(alkylamino)-s-triazines such as atrazine and simazine. The highest sensitivity was obtained with an Et/Cl/N-C-5-HRP tracer because this tracer could be used in combination with the lowest concentration of antibody. The detection limit was 0.1 mug l(-1) with a linear range between 0.1 and 10 mug l(-1) and an assay throughput of 12 h(-1). Natural water samples from various locations in Russia were analysed for triazines and the results were compared with a previously developed fluorescein how immunoassay for triazines. The results were further verified by supported liquid membrane (SLM) extraction combined with HPLC. The results show that the two immunoassays behave differently and that the sample matrix influences their performance, however, no false negative results were obtained. The possible reasons for the different results between the two immunoassays are discussed. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:197 / 207
页数:11
相关论文
共 36 条
[2]   Flow injection enzyme immunoassay of atrazine herbicide in water [J].
Bjarnason, B ;
Bousios, N ;
Eremin, SA ;
Johansson, G .
ANALYTICA CHIMICA ACTA, 1997, 347 (1-2) :111-120
[3]   IMMUNOASSAY ANALYSIS AND GAS-CHROMATOGRAPHY CONFIRMATION OF ATRAZINE RESIDUES IN WATER SAMPLES FROM A FIELD-STUDY CONDUCTED IN THE STATE OF WISCONSIN [J].
BRADY, JF ;
LEMASTERS, GS ;
WILLIAMS, RK ;
PITTMAN, JH ;
DAUBERT, JP ;
CHEUNG, MW ;
SKINNER, DH ;
TURNER, J ;
ROWLAND, MA ;
LANGE, J ;
SOBEK, SM .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1995, 43 (01) :268-274
[4]   Supported liquid membrane enrichment studies of natural water samples applied to liquid chromatographic determination of triazine herbicides [J].
Chimuka, L ;
Nindi, MM ;
Jönsson, JÅ .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 1997, 68 (04) :429-445
[5]   Analytical performance testing of an atrazine immunoassay system [J].
Comber, SDW ;
Watts, CD ;
Young, B .
ANALYST, 1996, 121 (10) :1485-1488
[6]   Continuous immunochemical determination of pesticides via flow injection immunoanalysis using monoclonal antibodies against terbutryne immobilized to solid supports [J].
Dietrich, M ;
Kramer, PM .
FOOD AND AGRICULTURAL IMMUNOLOGY, 1995, 7 (03) :203-220
[7]  
EKINS RP, 1985, ALTERNATIVE IMMUNOAS, P219
[8]   Flow injection immunoassays: a review [J].
Fintschenko, Y ;
Wilson, GS .
MIKROCHIMICA ACTA, 1998, 129 (1-2) :7-18
[9]  
Galassi S., 1991, Chinese Oggi, V9, P49
[10]   Performance of two immunoassays for the determination of atrazine in sea water samples as compared with on-line solid phase extraction liquid chromatography diode array detection [J].
Gascon, J ;
Oubina, A ;
Ferrer, I ;
Onnerfjord, P ;
MarkoVarga, G ;
Hammock, BD ;
Marco, MP ;
Barcelo, D .
ANALYTICA CHIMICA ACTA, 1996, 330 (01) :41-51