Doehlert matrix for optimisation of procedure for determination of nickel in saline oil-refinery effluents by use of flame atomic absorption spectrometry after preconcentration by cloud-point extraction

被引:45
作者
Bezerra, MD
Conceiçao, ALB
Ferreira, SLC
机构
[1] Univ Fed Bahia, Inst Quim, Grp Pesquisa Quim Analit, BR-40170290 Salvador, BA, Brazil
[2] Univ Estadual Sudoeste Bahia, Dept Quim & Exatas, BR-45200190 Jequie, BA, Brazil
关键词
oil-refinery waste; saline effluents; Doehlert matrix; flame atomic absorption spectrometry; cloud-point extraction; nickel;
D O I
10.1007/s00216-003-2349-4
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This paper proposes a preconcentration procedure for determination of nickel in saline aqueous waste samples by flame atomic absorption spectrometry (FAAS). It is based on cloud-point extraction of nickel(II) ions as 2-(5-bromo-2-pyridylazo)-5-diethilaminophenol (Br-PADAP) complexes using octylphenoxypolyethoxyethanol (Triton X-114) as surfactant. The optimisation step was performed using a four-variable Doehlert design, involving the factors centrifugation time (CT) of system after addition of surfactant, solution pH, methanol volume (MV) added at micellar phase, and buffer concentration (BC). The analytical response used was absorbance, after volume correction. Using the established experimental conditions in the optimisation step the procedure enables nickel determination with a detection limit (3delta/S) of 0.2 mug L-1, quantification limit (10delta/S) of 0.7 mug L-1, and precision, calculated as relative standard deviation (RSD) of 4.7 (n=8) and 3.5% (n=8) for nickel concentration of 1 and 5 mug L-1, respectively. The preconcentration factor, determined from the ratio of the slopes of the analytical curves with and without preconcentration, is 74. The recovery achieved for nickel determination in the presence of several cations demonstrated that this procedure could be applied for analysis of water samples. The robustness was checked by using saturated fractional factorial designs, centred on the established experimental conditions in the optimisation step. The results of these tests demonstrated that the variables centrifugation time and buffer concentration are robust for modification by 10% and that solution pH and methanol volume are robust for 5%. Accuracy was evaluated by using the certified material reference SLEW-3 estuarine water for trace metals. The procedure was used for determination of nickel in saline effluents from oil refinery samples. Recovery results (95-104%) indicate that the procedure has satisfactory accuracy for nickel determination in these samples.
引用
收藏
页码:798 / 803
页数:6
相关论文
共 41 条
[1]   Cloud-point extraction for the determination of Cd, Pb and Pd in blood by electrothermal atomic absorption spectrometry, using Ir or Ru as permanent modifiers [J].
Borges, DLG ;
da Veiga, MAMS ;
Frescura, VLA ;
Welz, B ;
Curtius, AJ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2003, 18 (05) :501-507
[2]   Decision protocol for checking robustness with previous outlier detection in the validation of analytical methods [J].
Bosque-Sendra, JM ;
Nechar, M ;
Rodríguez, LC .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 365 (06) :480-488
[3]   Cloud point preconcentration of germanium and determination by hydride generation atomic absorption spectrometry [J].
Böyükbayram, AE ;
Volkan, M .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2000, 55 (07) :1073-1080
[4]   Determination of cadmium, copper, lead and zinc in water samples by flame atomic absorption spectrometry after cloud point extraction [J].
Chen, JR ;
Teo, KC .
ANALYTICA CHIMICA ACTA, 2001, 450 (1-2) :215-222
[5]   Determination of cobalt and nickel in water samples by flame atomic absorption spectrometry after cloud point extraction [J].
Chen, JR ;
Teo, KC .
ANALYTICA CHIMICA ACTA, 2001, 434 (02) :325-330
[6]   Determination of Ag and Au in geological samples by flame atomic absorption spectrometry after cloud point extraction [J].
da Silva, MAM ;
Frescura, VLA ;
Aguilera, FJN ;
Curtius, AJ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1998, 13 (12) :1369-1373
[7]  
da Silva MAM, 2001, SPECTROCHIM ACTA B, V56, P1941
[8]  
da Silva MAM, 2000, SPECTROCHIM ACTA B, V55, P803
[9]   Sensitive determination of mercury in tap water by cloud point extraction pre-concentration and flow injection-cold vapor-inductively coupled plasma optical emission spectrometry [J].
de Wuilloud, JCA ;
Wuilloud, RG ;
Silva, MF ;
Olsina, RA ;
Martinez, LD .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2002, 57 (02) :365-374
[10]  
Doehlert D.H., 1970, Appl. Stat, V19, P231