Charge and voltage characteristics of corona discharges in a coaxial geometry

被引:30
作者
Cooray, V [1 ]
机构
[1] Univ Uppsala, Inst High Voltage Res, S-75105 Uppsala, Sweden
关键词
D O I
10.1109/94.891983
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
An engineering model is proposed to evaluate the variation of corona charge and corona current as a function of applied voltage for coaxial geometry (q-v curves). The two main assumptions of the model are the following: For streamer discharges to propagate continuously, the background field must be at, or just above, a critical level; and the streamers maintain a constant voltage gradient in the corona sheath. The model simulations are compared with the experimental q-v curves and a reasonable agreement is obtained between them.
引用
收藏
页码:734 / 743
页数:10
相关论文
共 29 条
[1]  
ANDERSSON NE, 1958, ARK FYS, V13, P441
[2]  
BLAIR DTA, 1978, BREAKDOWN VOLTAGE CH
[3]  
BLOM PPM, 1997, THESIS TU EINDHOVEN
[4]  
CABRERA VM, 1993, P 8 INT S HV ENG YOK
[5]   A MODEL FOR SUBSEQUENT RETURN STROKES [J].
COORAY, V .
JOURNAL OF ELECTROSTATICS, 1993, 30 :343-354
[6]   A model for negative first return strokes in lightning flashes [J].
Cooray, V .
PHYSICA SCRIPTA, 1997, 55 (01) :119-128
[7]  
COORAY V, 1996, J ATMOS ELECT, V16, P145
[8]  
DAVIS R, 1960, IEE MONOGRAPH, V415, P230
[9]   A MODEL FOR STREAMER PROPAGATION [J].
DAWSON, GA ;
WINN, WP .
ZEITSCHRIFT FUR PHYSIK, 1965, 183 (02) :159-&
[10]  
Galimberti I., 1979, J PHYSIQUE, V40, pC7