Validation by serial standardized testing of a new rate-responsive pacemaker sensor based on variations in myocardial contractility

被引:16
作者
Clémenty, J [1 ]
Kobeissi, A [1 ]
Garrigue, S [1 ]
Jaïs, P [1 ]
Le Métayer, P [1 ]
Haïssaguerre, M [1 ]
机构
[1] Hop Cardiol Haut Leveque, Dept Electtrophysiol & Stimulat Cardiaque, F-33604 Pessac, France
来源
EUROPACE | 2001年 / 3卷 / 02期
关键词
rate-responsive pacing; pacemaker sensor; peak endocardial acceleration; myocardial contractility;
D O I
10.1053/eupc.2001.0152
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims Preliminary studies have shown that peak endocardial acceleration (PEA), measured by a micro-accelerometer at the right ventricular apex, is highly correlated with left ventricular contractility (dp/dt max). Furthermore, changes in PEA are closely correlated with sinus node rate changes during exercise and during pharmacological interventions. Peak endocardial acceleration has, therefore, been used to drive a rate-responsive DDD pacemaker. This study compared the chronotropic performance of such devices implanted in 14 patients suffering from chronotropic incompetence with that observed in Is control subjects in normal sinus rhythm. Methods and Results Five standardized daily life activities (hall walk, climbing up and down stairs, squatting and hyperventilation) and two types of exercise (Bruce treadmill protocol and bicycle ergometry) were performed in a random order after individual programming of each pacemaker. For each test, a correlation coefficient was calculated between changes in PEA and variations in paced rate, between instantaneous variations in heart rate monitored by telemetry and continuous measurement of heart rate by the pacemaker, and between sensor-driven rate in patients and normal sinus rhythm in controls. The variations in paced heart rate were closely correlated with those observed in subjects with normal sinus rhythm, and proved to be sensitive, specific, rapid and independent of the type of exercise. After optimal programming of the sensor, PEA modulates the heart rate as expected during normal sinus rhythm. Conclusions In this study, a single PEA sensor successfully restored chronotropic response in a population of paced patients with severe chronotropic incompetence. Peak endocardial acceleration can be monitored on a beat-to-beat basis, in parallel with heart rate, and the pacemaker can be accurately programmed with a single exercise test. (Europace 2001; 3: 124-131) (C) 2001 The European Society of Cardiology.
引用
收藏
页码:124 / 131
页数:8
相关论文
共 30 条
[1]   CONTROL OF PACEMAKER RATE BY IMPEDANCE-BASED RESPIRATORY MINUTE VENTILATION [J].
ALT, E ;
HEINZ, M ;
HIRGSTETTER, C ;
EMSLANDER, HP ;
DAUM, S ;
BLOMER, H .
CHEST, 1987, 92 (02) :247-252
[2]   RATE CONTROL OF PHYSIOLOGICAL PACEMAKERS BY CENTRAL VENOUS-BLOOD TEMPERATURE [J].
ALT, E ;
HIRGSTETTER, C ;
HEINZ, M ;
BLOMER, H .
CIRCULATION, 1986, 73 (06) :1206-1212
[3]   INITIAL CLINICAL-EXPERIENCE WITH A NEW DUAL SENSOR SSIR PACEMAKER CONTROLLED BY BODY ACTIVITY AND MINUTE VENTILATION [J].
ALT, E ;
COMBS, W ;
FOTUHI, P ;
BAMBL, E ;
WAHLSTRAND, J ;
WILLHAUS, R .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1995, 18 (08) :1487-1495
[4]  
BAROLD SS, 1996, PROGR CLIN PACING, P153
[5]  
BINNER L, 1998, PACE, V21, P894
[6]   EMOTION PROFILES AND QUALITY-OF-LIFE OF PACED PATIENTS [J].
CATIPOVICVESELICA, K ;
SKRINJARIC, S ;
MRDENOVIC, S ;
MUJIC, N ;
CATIPOVIC, B ;
ANDRIC, M ;
VIZNERLOVRIC, I ;
LAUC, A .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1990, 13 (04) :399-404
[7]  
CHERADAME I, 1994, STIMUCOEUR, V22, P169
[8]   PHYSIOLOGICAL PRINCIPLES OF A NEW METHOD FOR RATE RESPONSIVE PACING USING THE PRE-EJECTION INTERVAL [J].
CHIRIFE, R .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1988, 11 (11) :1545-1554
[9]  
Clémenty J, 1999, AM J CARDIOL, V83, p166D
[10]   Dual chamber rate responsive pacing system driven by contractility:: Final assessment after 1-year follow-up [J].
Clémenty, J .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1998, 21 (11) :2192-2197