Full-field digital mammography

被引:28
作者
Bick, U
机构
[1] Univ Chicago, Dept Radiol, Chicago, IL 60637 USA
[2] Free Univ Berlin, Klinikum Charite, Inst Radiol, Berlin, Germany
来源
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN | 2000年 / 172卷 / 12期
关键词
digital mammography; breast cancer; screening; PACS; computer-assisted diagnosis;
D O I
10.1055/s-2000-9210
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Due to the extremely high image quality requirements in mammography, there has for a long time been no adequate digital alternative to conventional film-screen mammography. The longest experience so far exists with digital mammography on the basis of storage phosphor (CR) systems. However, at normal dose this technique has a relatively poor signal-to-noise ratio and has not found general acceptance. Recently three novel systems for digital mammography by the companies Fischer (slot-scan detector), Trex (CCD-array), and GE (amorphous silicon detector) have been introduced and are currently under clinical investigation. The main advantage of digital mammography is the linear relationship between dose and detector signal with the possibility of a tailored optimization of image contrast. Other advantages include digital image storage, telemammography, and computer-assisted diagnosis.
引用
收藏
页码:957 / 964
页数:8
相关论文
共 50 条
  • [1] Large picture archiving and communication systems of the world .1.
    Bauman, RA
    Gell, G
    Dwyer, SJ
    [J]. JOURNAL OF DIGITAL IMAGING, 1996, 9 (03) : 99 - 103
  • [2] Density correction of peripheral breast tissue on digital mammograms
    Bick, U
    Giger, ML
    Schmidt, RA
    Nishikawa, RM
    Doi, K
    [J]. RADIOGRAPHICS, 1996, 16 (06) : 1403 - 1411
  • [3] AUTOMATED SEGMENTATION OF DIGITIZED MAMMOGRAMS
    BICK, U
    GIGER, ML
    SCHMIDT, RA
    NISHIKAWA, RM
    WOLVERTON, DE
    DOI, K
    [J]. ACADEMIC RADIOLOGY, 1995, 2 (01) : 1 - 9
  • [4] Computer-aided diagnosis in screening mammography
    Bick, U
    [J]. RADIOLOGE, 1996, 36 (01): : 72 - 80
  • [5] BICK U, 2000, EUR RADIOL, V101, P116
  • [6] BLUME H, 1990, P SOC PHOTO-OPT INS, V1232, P97, DOI 10.1117/12.18846
  • [7] Motion artifact seen on slot-scanning direct digital mammography
    Boyle, ER
    Pak, D
    Williams, JB
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 172 (03) : 697 - 701
  • [8] A CLINICAL COMPARISON BETWEEN CONVENTIONAL AND DIGITAL MAMMOGRAPHY UTILIZING COMPUTED RADIOGRAPHY
    BRETTLE, DS
    WARD, SC
    PARKIN, GJS
    COWEN, AR
    SUMSION, HJ
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1994, 67 (797) : 464 - 468
  • [9] Thickness-equalization processing for mammographic images
    Byng, JW
    Critten, JP
    Yaffe, MJ
    [J]. RADIOLOGY, 1997, 203 (02) : 564 - 568
  • [10] DIGITAL MAMMOGRAPHY - ROC STUDIES OF THE EFFECTS OF PIXEL SIZE AND UNSHARP-MASK FILTERING ON THE DETECTION OF SUBTLE MICROCALCIFICATIONS
    CHAN, HP
    VYBORNY, CJ
    MACMAHON, H
    METZ, CE
    DOI, K
    SICKLES, EA
    [J]. INVESTIGATIVE RADIOLOGY, 1987, 22 (07) : 581 - 589