Precise measurements of the neutron magnetic form factor

被引:186
作者
Anklin, H [1 ]
deBever, LJ
Blomqvist, KI
Boeglin, WU
Bohm, R
Distler, M
Edelhoff, R
Friedrich, J
Fritschi, D
Geiges, R
Gotz, J
Honegger, A
Jennewein, P
Jourdan, J
Kahrau, M
Korn, M
Kramer, H
Krygier, KW
Kubon, G
Kunde, V
Liesenfeld, A
Masson, G
Merle, K
Neuhausen, R
Offermann, EAJM
Petitjean, T
Pospischil, T
Potokar, M
Qin, LM
Richter, AW
Rokavec, A
Rosner, G
Sauer, P
Schardt, S
Sick, I
Sirca, S
Trueb, P
Tuccillo, M
Vodenik, B
Wagner, A
Walcher, T
Warren, G
Wolf, S
Zhao, J
Zeier, M
Zihlmann, B
机构
[1] Univ Basel, Dept Phys & Astron, Basel, Switzerland
[2] Univ Ljubljana, Jozef Stefan Inst, Ljubljana, Slovenia
[3] Univ Mainz, Inst Kernphys, D-6500 Mainz, Germany
关键词
D O I
10.1016/S0370-2693(98)00442-0
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
The neutron magnetic form factor G(mn) has been determined via a measurement of the ratio of cross sections D(e,e'n) and D(e,e'p). The absolute detection efficiency of the neutron detector was measured with high accuracy using tagged neutrons produced from H(n,p)n elastic scattering by means of a high intensity neutron beam. This approach minimizes the model dependence and improves upon the weakest points of previous experiments. Data in the range q(2) = 0.2-0.8 (GeV/c)(2) with uncertainties of < 2% are presented. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:248 / 253
页数:6
相关论文
共 26 条
[1]   QUASIELASTIC ELECTRON-DEUTERON SCATTERING BETWEEN Q2 = 18 FM-2 AND 100 FM-2 [J].
ALBRECHT, W ;
BEHREND, HJ ;
DORNER, H ;
FLAUGER, W ;
HULTSCHIG, H .
PHYSICS LETTERS B, 1968, B 26 (10) :642-+
[2]   PRECISION-MEASUREMENT OF THE NEUTRON MAGNETIC FORM-FACTOR [J].
ANKLIN, H ;
BRUINS, EEW ;
DAY, D ;
FRITSCHI, D ;
GROFT, B ;
JOOSSE, FCP ;
JOURDAN, J ;
LICHTENSTADT, J ;
LOPPACHER, M ;
MASSON, G ;
MITCHELL, J ;
SICK, I ;
VANVEEN, HJJ .
PHYSICS LETTERS B, 1994, 336 (3-4) :313-318
[3]  
ARENHOEVEL H, 1993, COMMUNICATION
[4]   The nucleon facility NA at PSI [J].
Arnold, J ;
vandenBrandt, B ;
Daum, M ;
Einenkel, H ;
Franz, J ;
Goujon, N ;
Hautle, P ;
Heer, E ;
Hess, R ;
Humbel, M ;
Konter, JA ;
Lacker, H ;
LechanoineLeluc, C ;
Mango, S ;
Obermeier, H ;
Rapin, D ;
Rossle, E ;
Rohrer, U ;
Schirmaier, R ;
Schmelzbach, PA ;
Schmidt, M ;
Schmitt, H ;
Sereni, P ;
Teglia, A ;
Vuaridel, B .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 386 (2-3) :211-227
[5]   MEASUREMENT OF PROTON AND NEUTRON ELECTROMAGNETIC FORM-FACTORS AT SQUARED 4-MOMENTUM TRANSFERS UP TO 3 (GEV-C)2 [J].
BARTEL, W ;
BUSSER, FW ;
DIX, WR ;
FELST, R ;
HARMS, D ;
KREHBIEL, H ;
KUHLMANN, PE ;
MCELROY, J ;
MEYER, J ;
WEBER, G .
NUCLEAR PHYSICS B, 1973, 58 (02) :429-475
[6]  
BLOMQVIST KI, 1997, IN PRESS NUCL INSTR
[7]   LOW MOMENTUM TRANSFER NEUTRON FORM FACTORS FROM ANALYSIS OF DEUTERON ELECTRODISINTEGRATION [J].
BRAESS, D ;
HASSELMA.D ;
KRAMER, G .
ZEITSCHRIFT FUR PHYSIK, 1967, 198 (05) :527-&
[8]   MEASUREMENT OF THE NEUTRON MAGNETIC FORM-FACTOR [J].
BRUINS, EEW ;
BAUER, TS ;
DENBOK, HW ;
DUIF, CP ;
VANHOEK, WC ;
DELANGE, DJJ ;
MISIEJUK, A ;
PAPANDREOU, Z ;
SICHTERMANN, EP ;
TJON, JA ;
WILLERING, HW ;
YEOMANS, DM ;
REIKE, H ;
DUREK, D ;
FROMMBERGER, F ;
GOTHE, R ;
JAKOB, D ;
KRANEFELD, G ;
KUNZ, C ;
LEIENDECKER, N ;
PFEIFFER, G ;
PUTSCH, H ;
REICHELT, T ;
SCHOCH, B ;
WACKER, D ;
WEHRMEISTER, D ;
WILHELM, M ;
JANS, E ;
KONIJN, J ;
DEVRIES, R ;
FURGET, C ;
VOUTIER, E ;
ARENHOVEL, H .
PHYSICAL REVIEW LETTERS, 1995, 75 (01) :21-24
[9]   NEUTRON FORM FACTORS FROM QUASI-ELASTIC ELECTRON-DEUTERON SCATTERING [J].
BUDNITZ, RJ ;
APPEL, J ;
CARROLL, L ;
CHEN, J ;
DUNNING, JR ;
GOITEIN, M ;
HANSON, K ;
IMRIE, D ;
MISTRETTA, C ;
WALKER, JK ;
WILSON, R .
PHYSICAL REVIEW, 1968, 173 (05) :1357-+
[10]  
DEVRIES C, 1964, PHYS REV B, V134, P848