Use of computer-aided surgery for frontal sinus ventilation

被引:22
作者
Loehrl, TA [1 ]
Toohill, RJ [1 ]
Smith, TL [1 ]
机构
[1] Med Coll Wisconsin, Dept Otolaryngol & Commun Sci, Milwaukee, WI 53226 USA
关键词
frontal sinusitis; computer-aided surgery; endoscopic sinus surgery; complications; frontal recess;
D O I
10.1097/00005537-200011000-00037
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Objectives: To review our experience and evaluate the utility of computer-aided surgery for frontal sinus and frontal recess disease. Study Design: A retrospective review of 31 consecutive patients undergoing computer-aided surgery for frontal sinus ventilation, Methods: The hospital charts of 31 patients were reviewed. Previous sinonasal procedures, etiology of sinonasal disease, preoperative computed tomography(CT) scan findings, preoperative symptoms, endoscopic and intraoperative findings, type of frontal sinus ventilation procedure, complications, imaging system registration method or accuracy, and postoperative course were noted. Results: In all 31 patients the surgery was successfully completed, and no intracranial or orbital complications were encountered during or after surgery. Six patients required additional surgery including revision transnasal. endoscopic frontal sinus ventilation or osteoplastic flaps with fat obliteration. In the six cases requiring additional surgery, disease severity, most commonly, aspirin triad disease, predisposed to failure of frontal sinus ventilation. Conclusions: Computer-aided surgery is a useful adjunctive device for safe, efficient identification and surgery of the frontal sinus. However, it is not a replacement for sound surgical technique, anatomical knowledge, and experience. In particular, patients with aspirin triad disease with frontal recess and frontal sinus involvement are highly suited for computer-aided surgery and thorough removal of disease, although failures occur despite this technique. The long-term benefit of computer-aided surgery of the frontal sinus has not yet been demonstrated by this or other studies.
引用
收藏
页码:1962 / 1967
页数:6
相关论文
共 9 条
[1]   Computer-aided endoscopic sinus surgery [J].
Anon, JB .
LARYNGOSCOPE, 1998, 108 (07) :949-961
[2]  
Draf W., 1991, OP TECH OTOLARYNGOL, V2, P234, DOI [DOI 10.1016/S1043-1810(10)80087-9, 10.1016/S1043-1810(10)80087-9]
[3]   Image-guided endoscopic surgery: Results of accuracy and performance in a multicenter clinical study using an electromagnetic tracking system [J].
Fried, MP ;
Kleefield, J ;
Gopal, H ;
Reardon, E ;
Ho, BT ;
Kuhn, FA .
LARYNGOSCOPE, 1997, 107 (05) :594-601
[4]   A COMPUTED TOMOGRAPHIC STEREOTACTIC ADAPTATION SYSTEM [J].
GOERSS, S ;
KELLY, PJ ;
KALL, B ;
ALKER, GJ .
NEUROSURGERY, 1982, 10 (03) :375-379
[5]   Computer-assisted surgery in the frontal and maxillary sinus [J].
Gunkel, AR ;
Freysinger, W ;
Thumfart, WF .
LARYNGOSCOPE, 1997, 107 (05) :631-633
[6]  
Lund Valerie J., 1993, Rhinology (Utrecht), V31, P183
[7]   The role of image-guidance systems for head and neck surgery [J].
Metson, R ;
Cosenza, M ;
Gliklich, RE ;
Montgomery, WW .
ARCHIVES OF OTOLARYNGOLOGY-HEAD & NECK SURGERY, 1999, 125 (10) :1100-1104
[8]   A comparison of image guidance systems for sinus surgery [J].
Metson, R ;
Gliklich, RE ;
Cosenza, M .
LARYNGOSCOPE, 1998, 108 (08) :1164-1170
[9]  
STANKIEWICZ J, 1998, HEAD NECK SURG OTOLA, V1, P497