Role of home blood pressure monitoring in hemodialysis patients

被引:49
作者
Agarwal, R
机构
[1] Indiana Univ, Indianapolis, IN 46202 USA
[2] Richard L Roudebush Vet Affairs Med Ctr, Indianapolis, IN 46202 USA
关键词
hemodialysis; ambulatory blood pressure monitoring; home blood pressure;
D O I
10.1016/S0272-6386(99)70219-2
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
To investigate the use of manual home blood pressure (BP) monitoring in chronic hemodialysis patients, daily home BPs in 20 patients undergoing chronic hemodialysis were compared with the 44-hour interdialytic ambulatory BPs (ABPs), Each patient recorded home BPs for 2 consecutive weeks with a digital BP monitor three times daily, Prehemodialysis and posthemodialysis BPs were recorded by an oscillometric device in the hemodialysis unit during the same 2 weeks. ABPs were recorded either after the first or second hemodialysis session of the second week during a 44-hour interdialytic period using a Spacelab 90207 ABP monitor. ABP monitoring showed that BP decreased progressively after dialysis, decreased during the first night, and rapidly reached predialysis levels by the next morning. There was no decrease in BP during the second night. There was an excellent correlation between average systolic and diastolic ABP and respective home BPs, Prehemodialysis diastolic BPs were a good reflection of diastolic ABP, but there was more variability in predialysis systolic BP. Posthemodialysis BPs did not correlate with ABP. In patients undergoing chronic hemodialysis, home BPs more reliably reflected the overall BP than incenter BP readings. Predialysis, but not postdialysis, BP should be used as a screening tool to detect hypertension in the hemodialysis unit. Home BP monitoring should be used as a cost-effective means to diagnose occult hypertension in chronic hemodialysis patients. (C) 1999 by the National Kidney Foundation, Inc.
引用
收藏
页码:682 / 687
页数:6
相关论文
共 14 条
  • [1] DELAYED HYPOTENSIVE RESPONSE TO DIALYSIS IN HYPERTENSIVE PATIENTS WITH END-STAGE RENAL-DISEASE
    BATLLE, DC
    VONRIOTTE, A
    LANG, G
    [J]. AMERICAN JOURNAL OF NEPHROLOGY, 1986, 6 (01) : 14 - 20
  • [2] BLOOD-PRESSURE ELEVATION DURING THE NIGHT IN CHRONIC-RENAL-FAILURE, HEMODIALYSIS AND AFTER RENAL-TRANSPLANTATION
    BAUMGART, P
    WALGER, P
    GEMEN, S
    VONEIFF, M
    RAIDT, H
    HEINZ, K
    [J]. NEPHRON, 1991, 57 (03): : 293 - 298
  • [3] SURVIVAL AS AN INDEX OF ADEQUACY OF DIALYSIS
    CHARRA, B
    CALEMARD, E
    RUFFET, M
    CHAZOT, C
    TERRAT, JC
    VANEL, T
    LAURENT, G
    [J]. KIDNEY INTERNATIONAL, 1992, 41 (05) : 1286 - 1291
  • [4] CONTROL OF BLOOD-PRESSURE IN LONG SLOW HEMODIALYSIS
    CHARRA, B
    [J]. BLOOD PURIFICATION, 1994, 12 (4-5) : 252 - 258
  • [5] HYPERTENSION IS NOT ADEQUATELY CONTROLLED IN HEMODIALYSIS-PATIENTS
    CHEIGH, JS
    MILITE, C
    SULLIVAN, JF
    RUBIN, AL
    STENZEL, KH
    [J]. AMERICAN JOURNAL OF KIDNEY DISEASES, 1992, 19 (05) : 453 - 459
  • [6] Jacobs C, 1984, Contrib Nephrol, V41, P128
  • [7] WHAT IS THE VALUE OF HOME BLOOD-PRESSURE MEASUREMENT IN PATIENTS WITH MILD HYPERTENSION
    KLEINERT, HD
    HARSHFIELD, GA
    PICKERING, TG
    DEVEREUX, RB
    SULLIVAN, PA
    MARION, RM
    MALLORY, WK
    LARAGH, JH
    [J]. HYPERTENSION, 1984, 6 (04) : 574 - 578
  • [8] BLOOD-PRESSURE DURING THE INTERDIALYTIC PERIOD IN HEMODIALYSIS-PATIENTS - ESTIMATION OF REPRESENTATIVE BLOOD-PRESSURE VALUES
    KOOMAN, JP
    GLADZIWA, U
    BOCKER, G
    WIJNEN, JAG
    VONBORTEL, L
    LUIK, AJ
    DELEEUW, PW
    VONHOOFF, JP
    LEUNISSEN, KML
    [J]. NEPHROLOGY DIALYSIS TRANSPLANTATION, 1992, 7 (09) : 917 - 923
  • [9] LUIK AJ, 1994, NEPHROL DIAL TRANSPL, V9, P1616
  • [10] HYPERTENSION AND CARDIAC DEATH IN DIALYSIS PATIENTS - SHOULD TARGET BLOOD-PRESSURE BE LOWERED
    RITZ, E
    [J]. SEMINARS IN DIALYSIS, 1993, 6 (04) : 227 - 228