Reliability and validity of the maximal anaerobic running test

被引:37
作者
Nummela, A [1 ]
Alberts, M [1 ]
Rijntjes, RP [1 ]
Luhtanen, P [1 ]
Rusko, H [1 ]
机构
[1] UNIV LIMBURG,MAASTRICHT,NETHERLANDS
关键词
anaerobic capacity; anaerobic power; Wingate; blood lactate; reliability; validity; O-2; deficit;
D O I
10.1055/s-2007-972908
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Physically active men (n = 13) twice performed the Maximal Anaerobic Running Test (MART) on a treadmill and once the Wingate Anaerobic Test (WAnT) on a cycle ergometer. The MART consisted of n . 20-s runs with 100-s recovery between the runs. The speed of the first run was 14.6 km . h(-1) and the inclination 4 degrees. Thereafter, the speed was increased by 1.37 km . h(-1) every run until exhaustion. During all tests oxygen uptake was measured breath-by-breath and blood samples were taken from the fingertip 40 s after each run to determine the lactate concentration (BLa). Power at submaximal BLa levels and maximal power (P-5mM, P-10mM and P-max, respectively) were calculated and P was expressed as the oxygen demand of running according to the American College of Sports Medicine equation, In the MART the P-max was 108 ml . kg(-1) . min(-1) and peak BLa was 15.6 mM. The reliability for the power indices in the MART were as follows: r = 0.92 (p< 0.001) for P-max, r = 0.80 (p < 0.001) for P-10mM, and r = 0.67 (p = 0.01) for P-5mM. The average contribution of anaerobic energy expenditure was calculated to be 68% but it ranged from 64% to 72% during the MART. Although four out of seven of the correlations between the corresponding variables of the MART and WAnT were significant (0.52 < r < 0.59) they were not high. It is concluded that the anaerobic energy production is high in the MART, the test is reliable, and that the treadmill and cycle ergometer test measure slightly different qualities.
引用
收藏
页码:S97 / S102
页数:6
相关论文
共 25 条
[1]  
[Anonymous], 1974, INT SERIES SPORTS SC
[2]  
[Anonymous], GUID GRAD EX TEST EX
[3]  
Astrand P-O., 1986, Textbook of Work Physiology, V3, P295
[4]   THE WINGATE ANAEROBIC TEST - AN UPDATE ON METHODOLOGY, RELIABILITY AND VALIDITY [J].
BAROR, O .
SPORTS MEDICINE, 1987, 4 (06) :381-394
[5]   A SIMPLE METHOD FOR MEASUREMENT OF MECHANICAL POWER IN JUMPING [J].
BOSCO, C ;
LUHTANEN, P ;
KOMI, PV .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1983, 50 (02) :273-282
[6]   SPECIFICITY OF TEST DURATION WHEN ASSESSING THE ANAEROBIC LACTACID CAPACITY OF HIGH-PERFORMANCE TRACK CYCLISTS [J].
CRAIG, NP ;
PYKE, FS ;
NORTON, KI .
INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 1989, 10 (04) :237-242
[7]   LOAD OPTIMIZATION FOR THE WINGATE ANAEROBIC TEST [J].
DOTAN, R ;
BAROR, O .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1983, 51 (03) :409-417
[8]   PEAK BLOOD LACTATE AFTER SHORT PERIODS OF MAXIMAL TREADMILL RUNNING [J].
FUJITSUKA, N ;
YAMAMOTO, T ;
OHKUWA, T ;
SAITO, M ;
MIYAMURA, M .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1982, 48 (03) :289-296
[9]  
KAVANAGH MF, 1988, CAN J SPORT SCI, V13, P91
[10]  
KINDERMANN W, 1977, Canadian Journal of Applied Sport Sciences, V2, P177