Electrospray liquid chromatography quadrupole ion trap mass spectrometry determination of phenyl urea herbicides in water

被引:19
作者
Draper, WM [1 ]
机构
[1] Calif Dept Hlth Serv, Sanitat & Radiat Lab Branch, Berkeley, CA 94704 USA
关键词
electrospray; phenyl urea; herbicides; water;
D O I
10.1021/jf0011539
中图分类号
S [农业科学];
学科分类号
09 ;
摘要
Phenyl urea herbicides were determined in water by electrospray quadrupole ion trap liquid chromatography-mass spectrometry (ES-QIT-LC-MS). Over a wide concentration range [M - H](-) and MH+ ions were prominent in ES spectra. At high concentrations dimer and trimer ions appeared, and sodium, potassium, and ammonium adducts also were observed. In the case of isopturon, source collision-induced dissociation (CID) fragmentation with low offset voltages increased the ion current associated with MH+ and diminished dimer and trimer ion abundance. In the mass analyzer CID involved common pathways, for example, daughter ions of [M - H](-) resulted from loss of R2NH in N ' ,N ' -dialkyl ureas or loss of C3H5NO2 (87 amu) in N ' -methoxy ureas. A 2 mm (i.d.) x 15 cm C-18 reversed phase column was used for LC-MS with a linear methanol/water gradient and 0.5 mL/min flow rate. Between 1 and 100 pg/muL the response was highly linear with instrument detection limits ranging from < 10 to 50 pg injected. Whereas the positive ES signal intensity was greater for each of the compounds except fluometuron, negative ion monitoring gave the highest signal-to-noise ratio. Analysis of spiked Colorado River water, a source high in total dissolved solids and total organic carbon, demonstrated that ES-QIT-LC-MS was routinely capable of quantitative analysis at low nanogram per liter concentrations in conjunction with a published C-18 SPE method. Under these conditions experimental method detection limits were between 8.0 and 36 ng/L, and accuracy for measurements in the 20-50 parts per trillion range was from 77 to 96%. Recoveries were slightly lower in surface water (e.g., 39-76%), possibly due to suppression of ionization.
引用
收藏
页码:2746 / 2755
页数:10
相关论文
共 24 条
[1]  
[Anonymous], 1997, ELECTROSPRAY IONIZAT
[2]   Atmospheric pressure ionisation multiple mass spectrometric analysis of pesticides [J].
Baglio, D ;
Kotzias, D ;
Larsen, BR .
JOURNAL OF CHROMATOGRAPHY A, 1999, 854 (1-2) :207-220
[3]   Simultaneous determination of base/neutral and acid herbicides in natural water at the part per trillion level [J].
D'Ascenzo, G ;
Gentili, A ;
Marchese, S ;
Marino, A ;
Perret, D .
CHROMATOGRAPHIA, 1998, 48 (7-8) :497-505
[4]   ANALYSIS OF PESTICIDES USING LIQUID-CHROMATOGRAPHY ATMOSPHERIC-PRESSURE CHEMICAL IONIZATION MASS-SPECTROMETRY [J].
DOERGE, DR ;
BAJIC, S .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1992, 6 (11) :663-666
[5]   ATMOSPHERIC-PRESSURE ION-SAMPLING SYSTEM FOR LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY ANALYSES ON A BENCHTOP MASS-SPECTROMETER [J].
DUFFIN, KL ;
WACHS, T ;
HENION, JD .
ANALYTICAL CHEMISTRY, 1992, 64 (01) :61-68
[6]   Simultaneous determination of antifouling herbicides in marina water samples by on-line solid-phase extraction followed by liquid chromatography-mass spectrometry [J].
Ferrer, I ;
Barceló, D .
JOURNAL OF CHROMATOGRAPHY A, 1999, 854 (1-2) :197-206
[7]   Double-disk solid-phase extraction:: Simultaneous cleanup and trace enrichment of herbicides and metabolites from environmental samples [J].
Ferrer, I ;
Barceló, D ;
Thurman, EM .
ANALYTICAL CHEMISTRY, 1999, 71 (05) :1009-1015
[8]   MASS-TRANSPORT AND CALIBRATION IN LIQUID-CHROMATOGRAPHY PARTICLE BEAM MASS-SPECTROMETRY [J].
HO, JS ;
BEHYMER, TD ;
BUDDE, WL ;
BELLAR, TA .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1992, 3 (06) :662-671
[9]   Single short-column liquid chromatography with atmospheric pressure chemical ionization (tandem) mass spectrometric detection for trace environmental analysis [J].
Hogenboom, AC ;
Slobodnik, J ;
Vreuls, JJ ;
Rontree, JA ;
vanBaar, BLM ;
Niessen, WMA ;
Brinkman, UAT .
CHROMATOGRAPHIA, 1996, 42 (9-10) :506-514
[10]   On-line trace level determination of polar organic microcontaminants in water using various pre-column analytical column liquid chromatographic techniques with ultraviolet absorbance and mass spectrometric detection [J].
Hogenboom, AC ;
Jagt, I ;
Vreuls, RJJ ;
Brinkman, UAT .
ANALYST, 1997, 122 (11) :1371-1377