Implementations of two-dimensional liquid chromatography

被引:233
作者
Guiochon, Georges [1 ,2 ]
Marchetti, Nicola [1 ,2 ]
Mriziq, Khaled [1 ,2 ]
Shalliker, R. Andrew [3 ]
机构
[1] Univ Tennessee, Dept Chem, Knoxville, TN 37996 USA
[2] Oak Ridge Natl Lab, Div Chem & Analyt Sci, Oak Ridge, TN 37831 USA
[3] Univ Western Sydney, Penrith, NSW 1797, Australia
关键词
band interference; peak capacity; separation efficiency; separations in space; separations in time; three-dimensional chromatography; two-dimensional chromatography; two-dimensional thin-layer chromatography; thin layer chromatography; one-dimensional chromatography;
D O I
10.1016/j.chroma.2008.01.086
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Today scientists must deal with complex samples that either cannot be adequately separated using one-dimensional chromatography or that require an inordinate amount of time for separation. For these cases we need two-dimensional chromatography because it takes far less time to generate a peak capacity n(c) twice in a row than to generate a peak capacity n(c)(2) once. Liquid chromatography has been carried out successfully on thin layers of adsorbents and along tubes filled with various adsorbents. The first type of separation sorts out the sample components in a physical separation space that is the layer of packing material. The analysis time is the same for all the components of the sample while their migration distance increases with decreasing retention. The resolution between two components having a certain separation factor (alpha) increases with increasing migration distance, i.e., from the strongly to the weakly retained compounds. In the second type of separation, the sample components are eluted from the column and separated in the time space, their migration distances are all the same while their retention times increase from the unretained to the strongly retained compounds. Separation efficiency varies little with retention, as long as the components are eluted from the column. We call these two types of separation the chromatographic separations in space (LCx) and the chromatographic separations in time (LC'), respectively. In principle, there are four ways to combine these two modes and do two-dimensional chromatographic separations, LC' x LC', LC' x LC', LC' x LC', and LC' x LC'. We review, discuss and compare the potential performance of these combinations, their advantages, drawbacks, problems, perspectives and results. Currently, column-based combinations (LC' x LC') are the most actively pursued. We suggest that the combination LC' x LC' shows exceptional promise because it permits the simultaneous second-dimension separations of all the fractions separated in the first-dimension, thus providing remarkable time saving. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:109 / 168
页数:60
相关论文
共 203 条
[1]   A multi-dimensional high performance liquid chromatographic method for fingerprinting polycyclic aromatic hydrocarbons and their alkyl-homologs in the heavy gas oil fraction of Alaskan North Slope crude [J].
Aravanabhavan, Gurusankar S. ;
Helferty, Anjali ;
Hodson, Peter V. ;
Brown, R. Stephen .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1156 (1-2) :124-133
[2]  
BEAVER LA, 1984, Patent No. 4469601
[3]   A theoretical basis for parameter selection and instrument design in comprehensive size-exclusion chromatography x liquid chromatography [J].
Bedani, Filippo ;
Kok, Wim Th. ;
Janssen, Hans-Gerd .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1133 (1-2) :126-134
[4]   THEORY OF THIN-LAYER CHROMATOGRAPHY - EFFECT OF STRUCTURE OF ADSORPTION LAYER ON SPREADING OF SPOTS [J].
BELENKII, BG ;
KOLEGOV, VI ;
NESTEROV, VV .
JOURNAL OF CHROMATOGRAPHY, 1975, 107 (02) :265-283
[5]   AUTOMATED INSTRUMENTATION FOR COMPREHENSIVE 2-DIMENSIONAL HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF PROTEINS [J].
BUSHEY, MM ;
JORGENSON, JW .
ANALYTICAL CHEMISTRY, 1990, 62 (02) :161-167
[6]   Visualising the onset of viscous fingering in chromatography columns [J].
Catchpoole, Heather J. ;
Shalliker, R. Andrew ;
Dennis, Gary R. ;
Guiochon, Georges .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1117 (02) :137-145
[7]   EFFECT OF PEAK SENSING AND RANDOM NOISE ON PRECISION AND ACCURACY OF STATISTICAL MOMENT ANALYSES FROM DIGITAL CHROMATOGRAPHIC DATA [J].
CHESLER, SN ;
CRAM, SP .
ANALYTICAL CHEMISTRY, 1971, 43 (14) :1922-&
[8]  
Churacek JP, 1985, GRADIENT ELUTION COL
[9]  
CHURACEK P, 1985, GRADIENT ELUTION COL
[10]  
Cohen SA, 2007, MULTIDIMENSIONAL LIQ