Randoms variance reduction in 3D PET

被引:54
作者
Badawi, RD
Miller, MP
Bailey, DL
Marsden, PK
机构
[1] Univ London Kings Coll, Div Radiol Sci & Med Engn, Guys & St Thomas Clin PET Ctr, London WC2R 2LS, England
[2] Hammersmith Hosp, MRC, Cyclotron Unit, London W12 0NN, England
关键词
D O I
10.1088/0031-9155/44/4/010
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In positron emission tomography (PET), random coincidence events must be removed from the measured signal in order to obtain quantitatively accurate data. The most widely implemented technique for estimating the number of random coincidences on a particular line of response is the delayed coincidence channel method. Estimates obtained in this way are subject to Poisson noise, which then propagates into the final image when the estimates are subtracted from the prompt signal. However, this noise may be reduced if variance reduction techniques similar to those used in normalization of PET detectors are applied to the randoms estimates prior to use. We have investigated the effects of randoms variance reduction on noise-equivalent count (NEC) rates on a whole-body PET camera operating in 3D mode. NEC rates were calculated using a range of phantoms representative of situations that might be encountered clinically. We have also investigated the properties of three randoms variance reduction methods (based on algorithms previously used for normalization) in terms of their systematic accuracy and their variance reduction efficacy, both in phantom studies and in vivo. Those algorithms investigated that do not make assumptions about the spatial distribution of random coincidences give the best estimates of the randoms distribution. With the camera used, which has a limited axial extent (10.8 cm) and a large ring diameter (102 cm), the gains in image signal-to-noise ratio obtained with this technique ranged from similar to 5% to similar to 15%, depending on object size, activity distribution and the amount of activity in the field of view. Larger gains would be expected if this technique were to be employed on cameras of greater axial extent and smaller ring diameter.
引用
收藏
页码:941 / 954
页数:14
相关论文
共 14 条
[1]   Algorithms for calculating detector efficiency normalization coefficients for true coincidences in 3D PET [J].
Badawi, RD ;
Lodge, MA ;
Marsden, PK .
PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (01) :189-205
[2]   Optimization of noise-equivalent count rates in 3D PET [J].
Badawi, RD ;
Marsden, PK ;
Cronin, BF ;
Sutcliffe, JL ;
Maisey, MN .
PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (09) :1755-1776
[3]   Experience with fully 3D PET and implications for future high-resolution 3D tomographs [J].
Bailey, DL ;
Miller, MP ;
Spinks, TJ ;
Bloomfield, PM ;
Livieratos, L ;
Young, HE ;
Jones, T .
PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (04) :777-786
[4]   QUANTITATION IN POSITRON EMISSION COMPUTED-TOMOGRAPHY .7. A TECHNIQUE TO REDUCE NOISE IN ACCIDENTAL COINCIDENCE MEASUREMENTS AND COINCIDENCE EFFICIENCY CALIBRATION [J].
CASEY, ME ;
HOFFMAN, EJ .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1986, 10 (05) :845-850
[5]  
GUZZARDI R, 1990, PERFORMANCE EVALUATI, pCH5
[6]   PET SYSTEM CALIBRATIONS AND CORRECTIONS FOR QUANTITATIVE AND SPATIALLY ACCURATE IMAGES [J].
HOFFMAN, EJ ;
GUERRERO, TM ;
GERMANO, G ;
DIGBY, WM ;
DAHLBOM, M .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1989, 36 (01) :1108-1112
[7]   QUANTITATION IN POSITRON EMISSION COMPUTED-TOMOGRAPHY .4. EFFECT OF ACCIDENTAL COINCIDENCES [J].
HOFFMAN, EJ ;
HUANG, SC ;
PHELPS, ME ;
KUHL, DE .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1981, 5 (03) :391-400
[8]  
Jones T., 1996, Journal of Nuclear Medicine, V37, p85P
[9]  
JORDAN K, 1990, PERFORMANCE EVALUATI
[10]   ANALYTIC 3D IMAGE-RECONSTRUCTION USING ALL DETECTED EVENTS [J].
KINAHAN, PE ;
ROGERS, JG .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1989, 36 (01) :964-968