High-resolution gamma-ray spectrometers using bulk absorbers coupled to Mo/Cu multilayer superconducting transition-edge sensors

被引:12
作者
Chow, DT [1 ]
Loshak, A [1 ]
van den Berg, ML [1 ]
Frank, M [1 ]
Barbee, TW [1 ]
Labov, SE [1 ]
机构
[1] Univ Calif Davis, Dept Appl Sci, Davis, CA 95616 USA
来源
HARD X-RAY GAMMA-RAY AND NEUTRON DETECTOR PHYSICS II | 2000年 / 4141卷
关键词
microcalorimeter; cryogenic detector; gamma-ray spectroscopy;
D O I
10.1117/12.407605
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In x-ray and gamma-ray spectroscopy, it is desirable to have detectors with high energy resolution and high absorption efficiency. At LLNL, we have developed superconducting tunnel junction-based single photon x-ray detectors with thin film absorbers that have achieved these goals for photon energies up to 1 keV. However, for energies above 1 keV, the absorption efficiency of these thin-film detectors decreases drastically. We are developing the use of high-purity superconducting bulk materials as microcalorimeter absorbers for high-energy x-rays and gamma rays. The increase in absorber temperature due to incident photons is sensed by a superconducting transition-edge sensor (TES) composed of a Mo/Cu multilayer thin film. Films of Mo and Cu are mutually insoluble and therefore very stable and can be annealed. The multilayer structure allows scaling in thickness to optimize heat capacity and normal state resistance. We measured an energy resolution of 70 eV for 60 keV incident gamma-rays with a 1 x 1 x 0.25 mm(3) Sn absorber. We present x-ray and gamma-ray results from this detector design with a Sn absorber. We also propose the use of an active negative feedback voltage bias to improve the performance of our detector and show preliminary results.
引用
收藏
页码:67 / 75
页数:9
相关论文
共 15 条
[1]   High energy resolution bolometers for nuclear physics and x-ray spectroscopy [J].
Alessandrello, A ;
Beeman, JW ;
Brofferio, C ;
Cremonesi, O ;
Fiorini, E ;
Giuliani, A ;
Haller, EE ;
Monfardini, A ;
Nucciotti, A ;
Pavan, M ;
Pessina, G ;
Previtali, E ;
Zanotti, L .
PHYSICAL REVIEW LETTERS, 1999, 82 (03) :513-515
[2]   Low-temperature X-ray detectors for precise Lamb shift measurements on hydrogen-like heavy ions [J].
Bleile, A ;
Egelhof, P ;
Kluge, HJ ;
Liebisch, U ;
McCammon, D ;
Meier, HJ ;
Sebastián, O ;
Stahle, CK ;
Weber, M .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 444 (1-2) :488-491
[3]   Gamma-ray spectrometers using a bulk Sn absorber coupled to a Mo/Cu multilayer superconducting transition edge sensor [J].
Chow, DT ;
Lindeman, MA ;
Cunningham, MF ;
Frank, M ;
Barbee, TW ;
Labov, SE .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 444 (1-2) :196-200
[4]   Energy resolution and high count rate performance of superconducting tunnel junction x-ray spectrometers [J].
Frank, M ;
Hiller, LJ ;
le Grand, JB ;
Mears, CA ;
Labov, SE ;
Lindeman, MA ;
Netel, H ;
Chow, D ;
Barfknecht, AT .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1998, 69 (01) :25-31
[5]   Measurements of thermal transport in low stress silicon nitride films [J].
Holmes, W ;
Gildemeister, JM ;
Richards, PL ;
Kotsubo, V .
APPLIED PHYSICS LETTERS, 1998, 72 (18) :2250-2252
[6]  
Irwin K, 1995, THESIS STANFORD U
[7]   X-ray detection using a superconducting transition-edge sensor microcalorimeter with electrothermal feedback [J].
Irwin, KD ;
Hilton, GC ;
Wollman, DA ;
Martinis, JM .
APPLIED PHYSICS LETTERS, 1996, 69 (13) :1945-1947
[8]  
Knoll G. F, 1999, Radiation detection and measurement, V2nd
[9]  
LINDEMAN M, 2000, THESIS U CALIF DAVIS
[10]   Analysis of pulse shape from a high-resolution superconducting tunnel junction X-ray spectrometer [J].
Mears, CA ;
Labov, SE ;
Frank, M ;
Lindeman, MA ;
Hiller, LJ ;
Netel, H ;
Barfknecht, AT .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 370 (01) :53-56