Diaphragm pacing with a quadripolar phrenic nerve electrode: An international study

被引:56
作者
WeeseMayer, DE
Silvestri, JM
Kenny, AS
Ilbawi, MN
Hauptman, SA
Lipton, JW
Talonen, PP
Garcia, HG
Watt, JW
Exner, G
Baer, GA
Elefteriades, JA
Peruzzi, WT
Alex, CG
Harlid, R
Vincken, W
Davis, GM
Decramer, M
Kuenzle, C
Saeterhaug, A
Schober, JG
机构
[1] TAMPERE UNIV TECHNOL,SIGNAL PROC LAB,FIN-33101 TAMPERE,FINLAND
[2] UNIV AUTONOMA MADRID,CATEDRAT CIRUGIA,MADRID,SPAIN
[3] DIST GEN HOSP,SOUTHPORT,ENGLAND
[4] WORKMENS COMPENSAT HOSP,HAMBURG,GERMANY
[5] TAMPERE UNIV HOSP,TAMPERE,FINLAND
[6] YALE UNIV,MED CTR,NEW HAVEN,CT
[7] NORTHWESTERN MEM HOSP,CHICAGO,IL
[8] EDWARD HINES JR VET ADM HOSP,HINES,IL 60141
[9] DANDERYD HOSP,S-18288 DANDERYD,SWEDEN
[10] UNIV BRUSSELS,ACAD HOSP,BRUSSELS,BELGIUM
[11] MONTREAL CHILDRENS HOSP,MONTREAL,PQ H3H 1P3,CANADA
[12] LEUVEN UNIV HOSP,LOUVAIN,BELGIUM
[13] TRONDHEIM REG & UNIV HOSP,TRONDHEIM,NORWAY
[14] KINDERKLIN LACHNERSTR,MUNICH,GERMANY
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 1996年 / 19卷 / 09期
关键词
Congenital Central Hypoventilation syndrome; tetraplegia; pediatric; adult;
D O I
10.1111/j.1540-8159.1996.tb04209.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We sought to determine the international experience with the quadripolar diaphragm pacer system and to test two hypotheses: the incidence of pacer complications would be (1) increased among pediatric as compared to adult patients; and (2) highest among active pediatric patients with idiopathic congenital central hypoventilation syndrome (CCHS). Data were collected via a questionnaire coupled with the Atrotech Registry data for a total of 64 patients (35 children and 29 adults) from 14 countries. Thoracic implantation of electrodes and bilateral pacer use each occurred in 94% of all subjects. Tetraplegic (vs pediatric CCHS) patients were more typically paced 24 hours/day (P = 0.001). Pacing duration averaged 2.0 +/- 1.0 years among children and 2.2 +/- 1.1 years among adults. Infections occurred among 2.9% of surgical procedures, all in pediatric CCHS patients (vs pediatric tetraplegic patients, P = 0.01). The incidence of mechanical trauma was 3.8%, without significant differences among patient groups. The incidence of presumed electrode and receiver failure were 3.1% and 5.9%, respectively with infernal component failure greater among pediatric CCHS than pediatric tetraplegic patients (P < 0.01). Intermittent or absent function of 0-4 electrode combinations occurred among 19% of all patients, with increased frequency among pediatric CCHS than pediatric tetraplegic patients (P < 0.03). Complication-free successful pacing occurred in 60% of pediatric and 52% of adult patients. In all, 94% of the pediatric and 86% of the adult patients paced successfully after the necessary intervention. Although pacer complications were not increased among pediatric as compared to adult patients, the incidence of complications was highest among the active pediatric patients with CCHS. Longitudinal study of these patients will provide invaluable information for modification and improvement of the quadripolar system.
引用
收藏
页码:1311 / 1319
页数:9
相关论文
共 8 条
[1]   FUNDAMENTAL CONSIDERATIONS IN PACING OF THE DIAPHRAGM FOR CHRONIC VENTILATORY INSUFFICIENCY - A MULTI-CENTER STUDY [J].
GLENN, WWL ;
BROUILLETTE, RT ;
DENTZ, B ;
FODSTAD, H ;
HUNT, CE ;
KEENS, TG ;
MARSH, HM ;
PANDE, S ;
PIEPGRAS, DG ;
VANDERLINDEN, RG .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1988, 11 (11) :2121-2127
[2]   20 YEARS OF EXPERIENCE IN PHRENIC-NERVE STIMULATION TO PACE THE DIAPHRAGM [J].
GLENN, WWL ;
PHELPS, ML ;
ELEFTERIADES, JA ;
DENTZ, B ;
HOGAN, JF .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1986, 9 (06) :780-784
[3]  
GLENN WWL, 1964, ANN SURG, V160, P338
[4]   RADIO-FREQUENCY ELECTROPHRENIC RESPIRATION - LONG-TERM APPLICATION TO A PATIENT WITH PRIMARY HYPOVENTILATION [J].
JUDSON, JP ;
GLENN, WWL .
JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1968, 203 (12) :1033-&
[5]   NEUROPHYSIOLOGICAL AND TECHNICAL CONSIDERATIONS FOR THE DESIGN OF AN IMPLANTABLE PHRENIC-NERVE STIMULATOR [J].
TALONEN, PP ;
BAER, GA ;
HAKKINEN, V ;
OJALA, JK .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1990, 28 (01) :31-37
[6]   ELECTROPHRENIC RESPIRATION BY RADIOFREQUENCY INDUCTION [J].
VANHEECKEREN, DW ;
GLENN, WWL .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1966, 52 (05) :655-+
[7]   DIAPHRAGM PACING IN INFANTS AND CHILDREN [J].
WEESEMAYER, DE ;
HUNT, CE ;
BROUILLETTE, RT ;
SILVESTRI, JM .
JOURNAL OF PEDIATRICS, 1992, 120 (01) :1-8
[8]   DIAPHRAGM PACING IN INFANTS AND CHILDREN - A LIFE-TABLE ANALYSIS OF IMPLANTED COMPONENTS [J].
WEESEMAYER, DE ;
MORROW, AS ;
BROUILLETTE, RT ;
ILBAWI, MN ;
HUNT, CE .
AMERICAN REVIEW OF RESPIRATORY DISEASE, 1989, 139 (04) :974-979