Desorption electrospray ionization mass spectrometry for high-throughput analysis of pharmaceutical samples in the ambient environment

被引:304
作者
Chen, HW [1 ]
Talaty, NN [1 ]
Takáts, Z [1 ]
Cooks, RG [1 ]
机构
[1] Purdue Univ, Dept Chem, W Lafayette, IN 47907 USA
关键词
D O I
10.1021/ac050989d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Desorption electrospray ionization (DESI) allows mass spectrometry to be used for on-line high-throughput monitoring of pharmaceutical samples in the ambient environment, without prior sample preparation. Positive and negative ion DESI are used to characterize the active ingredients in pharmaceutical samples formulated as tablets, ointments, and liquids. Compounds of a wide variety of chemical types are detected in these complex matrices. The effects on analytical performance of operating parameters, including the electrospray high voltage, heated capillary temperature, solvent infusion rate, and solvent composition, are evaluated and optimized. In addition to experiments in which a simple solvent is sprayed onto the solid analyte samples, reactive desorption is performed by adding reagents to the solvent spray to generate particularly stable or characteristic ions with the analytes of interest. A variable-speed moving belt was built for high-throughput sampling and used to provide rapid qualitative and semiquantitative information on drug constituents in tablets. Sampling rates as high as 3 samples/s are achieved in the ambient environment. Relative standard deviations of the relative ion abundances for major components in the mass spectra are in the range of 2-8%. Impurities and components present at levels as low as similar to 0.1% are identified and carryover effects are minimized in high-throughput on-line analysis of pharmaceutical samples.
引用
收藏
页码:6915 / 6927
页数:13
相关论文
共 53 条
  • [1] Ackermann Bradley L., 2002, Current Topics in Medicinal Chemistry, V2, P53, DOI 10.2174/1568026023394605
  • [2] A miniature cylindrical quadrupole ion trap: Simulation and experiment
    Badman, ER
    Johnson, RC
    Plass, WR
    Cooks, RG
    [J]. ANALYTICAL CHEMISTRY, 1998, 70 (23) : 4896 - 4901
  • [3] Development of sampling methods for Raman analysis of solid dosage forms of therapeutic and illicit drugs
    Bell, SEJ
    Beattie, JR
    McGarvey, JJ
    Peters, KL
    Sirimuthu, NMS
    Speers, SJ
    [J]. JOURNAL OF RAMAN SPECTROSCOPY, 2004, 35 (05) : 409 - 417
  • [4] BRYDEN WA, 1995, J HOPKINS APL TECH D, V16, P296
  • [5] Rapid simultaneous quantification of immunosuppressants in transplant patients by turbulent flow chromatography combined with tandem mass spectrometry
    Ceglarek, U
    Lembcke, J
    Fiedler, GM
    Werner, M
    Witzigmann, H
    Hauss, JP
    Thiery, J
    [J]. CLINICA CHIMICA ACTA, 2004, 346 (02) : 181 - 190
  • [6] Versatile new ion source for the analysis of materials in open air under ambient conditions
    Cody, RB
    Laramée, JA
    Durst, HD
    [J]. ANALYTICAL CHEMISTRY, 2005, 77 (08) : 2297 - 2302
  • [7] COLLISIONS OF POLYATOMIC IONS WITH SURFACES
    COOKS, RG
    AST, T
    MABUD, A
    [J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 1990, 100 : 209 - 265
  • [8] Cotter RJ, 1999, J MASS SPECTROM, V34, P1368, DOI 10.1002/(SICI)1096-9888(199912)34:12<1368::AID-JMS905>3.0.CO
  • [9] 2-S
  • [10] On-line coupling of high-performance liquid chromatography to a continuous-flow enzyme assay based on electrospray ionization mass spectrometry
    de Boer, AR
    Letzel, T
    van Elswijk, DA
    Lingeman, H
    Niessen, WMA
    Irth, H
    [J]. ANALYTICAL CHEMISTRY, 2004, 76 (11) : 3155 - 3161