The use of mass spectrometric immunoassay (MSIA) in analyzing beta -2-microglobulin (beta (2)m) present in human biological fluids (tears, saliva, plasma, and urine) is described, Pipettor tips containing porous affinity frits, derivatized with polyclonal anti-beta (2)m immunoglobulin, mere manufactured and used to selectively isolate and concentrate beta (2)m from the biofluids, after which matrix-assisted laser desorption/ionization time-of-flight. mass spectrometry was used to detect beta (2)m unambiguously at its characteristic molecular mass. The affinity tips were found rapid to use, requiring approximately 15 min per analysis, and exhibited low nonspecific binding properties that yielded essentially interference-free analyses. The beta (2)m MSIA was made quantitative by inclusion of an internal standard into the analysis for signal normalization. The resulting assay had a Linear dynamic range (R-2 = 0.983) covering a beta (2)m concentration range of 0.010-1.0 mg/L with a standard error of approximately 5%. In application, urine samples from healthy individuals were screened and compared with sample from an individual suffering from renal infection. Results indicated an approximately 30-fold increase in beta (2)m levels in samples taken from the infected individual. During the screening, MSIA was able to distinguish between wild-type and glycosylated forms of beta (2)m, which made possible the accurate quantification of mild-type beta (2)m without interference from glycosylated versions of the protein. These results demonstrate a new approach to the rapid and accurate detection/quantification of beta (2)m present in biological fluids. (C) 2001 Academic Press.
引用
收藏
页码:26 / 35
页数:10
相关论文
共 25 条
[1]  
AULBERT E, 1990, MED KLIN, V85, P13
[2]  
COTTER RJ, 1997, TIME OF FLIGHT MASS
[3]  
DURIE BGM, 1990, BLOOD, V75, P823
[4]   ELECTROSPRAY IONIZATION FOR MASS-SPECTROMETRY OF LARGE BIOMOLECULES [J].
FENN, JB ;
MANN, M ;
MENG, CK ;
WONG, SF ;
WHITEHOUSE, CM .
SCIENCE, 1989, 246 (4926) :64-71
[5]  
HILLENKAMP F, 1991, ANAL CHEM, V63, pA1193
[6]   LASER DESORPTION IONIZATION OF PROTEINS WITH MOLECULAR MASSES EXCEEDING 10000 DALTONS [J].
KARAS, M ;
HILLENKAMP, F .
ANALYTICAL CHEMISTRY, 1988, 60 (20) :2299-2301
[7]   Mass spectrometric immunoassay [J].
Krone, JR ;
Nelson, RW ;
Williams, P .
ULTRASENSITIVE BIOCHEMICAL DIAGNOSTICS, PROCEEDINGS OF, 1996, 2680 :415-421
[8]   Measurement of beta(2)-microglobulin in bovine serum and urine by radioimmunoassay [J].
Kunugiyama, I ;
Ito, N ;
Takagaki, Y ;
Hayashi, S ;
Sone, K ;
Gotoh, H ;
Saitoh, T ;
Furukawa, Y ;
Yamaguchi, T .
JOURNAL OF VETERINARY MEDICAL SCIENCE, 1996, 58 (07) :617-622
[9]   Bactericidal domain of lactoferrin: Detection, quantitation, and characterization of lactoferricin in serum by SELDI affinity mass spectrometry [J].
Kuwata, H ;
Yip, TT ;
Yip, CL ;
Tomita, M ;
Hutchens, TW .
BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 1998, 245 (03) :764-773
[10]   SERUM BETA-2-MICROGLOBULIN AND PREDICTION OF PROGRESSION TO AIDS IN HIV-INFECTION [J].
LIFSON, AR ;
HESSOL, NA ;
BUCHBINDER, SP ;
OMALLEY, PM ;
BARNHART, L ;
SEGAL, M ;
KATZ, MH ;
HOLMBERG, SD .
LANCET, 1992, 339 (8807) :1436-1440