Calibration transfer for solving the signal instability in quantitative headspace-mass spectrometry

被引:40
作者
Pavón, JLP [1 ]
Sánchez, MD [1 ]
Pinto, CG [1 ]
Laespada, MEF [1 ]
Cordero, BM [1 ]
机构
[1] Univ Salamanca, Fac Ciencias Quim, Dept Quim Analit Nutr & Bromatol, Salamanca 37008, Spain
关键词
D O I
10.1021/ac034543d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
It is reported that calibration transfer is able to compensate the variations in sensitivity in direct coupling of a headspace sampler to a mass spectrometer when used for quantification purposes using multivariate calibration techniques. This strategy of signal stability compensation allows the use of models constructed from large calibration standard sets without having to repeat their measurement even though variations occur in sensitivity, which may or may not be constant along the mass range. This technique offers advantages over the use of internal standards in this methodology and only requires the measurement of a small number of transfer samples with each set of unknown samples. The results obtained in the determination of six volatile organic compounds-benzene, toluene, ethylbenzene, and m-xylene (BTEX), methyl tertbutyl ether (MTBE), and mesitylene-are reported. To obtain an appropriate calibration set, a Plackett-Burman design with five levels of concentration for each component was employed. A PLS multivariate calibration model was constructed with a group of 25 samples. For selection of the optimum number of principal components, an external validation set (5 samples) was used and the prediction capacity of this set was checked with an additional group of samples that had not been used either in the construction or in the validation of the model. The results obtained can be considered highly satisfactory, and the methodology was successfully tested with natural matrixes (river and tap water).
引用
收藏
页码:6361 / 6367
页数:7
相关论文
共 30 条
  • [1] Experimental design .3. Quantification
    Araujo, PW
    Brereton, RG
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1996, 15 (03) : 156 - 163
  • [2] Multilevel multifactor designs for multivariate calibration
    Brereton, RG
    [J]. ANALYST, 1997, 122 (12) : 1521 - 1529
  • [3] Introduction to multivariate calibration in analytical chemistry
    Brereton, RG
    [J]. ANALYST, 2000, 125 (11) : 2125 - 2154
  • [4] *CAM PROC AS, 2002, UNSCR V7 8
  • [5] Reversed-phase membrane inlet mass spectrometry applied to the real-time monitoring of low molecular weight alcohols in chloroform
    Creaser, CS
    Lamarca, DG
    Brum, J
    Werner, C
    New, AP
    dos Santos, LMF
    [J]. ANALYTICAL CHEMISTRY, 2002, 74 (01) : 300 - 304
  • [6] Use of a Plackett-Burman design with multivariate calibration for the analysis of polycyclic aromatic hydrocarbons in micellar media by synchronous fluorescence
    Devos, O
    Fanget, B
    Saber, AI
    Paturel, L
    Naffrechoux, E
    Jarosz, J
    [J]. ANALYTICAL CHEMISTRY, 2002, 74 (03) : 678 - 683
  • [7] Use of the MS-sensor to discriminate between different dosages of garlic flavoring in tomato sauce
    Dittmann, B
    Zimmermann, B
    Engelen, C
    Jany, G
    Nitz, S
    [J]. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2000, 48 (07) : 2887 - 2892
  • [8] DITTMANN B, 2000, SENSOR ACTUATOR, V69, P23
  • [9] Feundale RN, 2002, CHEMOMETR INTELL LAB, V64, P181
  • [10] An electronic nose system for monitoring the quality of potable water
    Gardner, JW
    Shin, HW
    Hines, EL
    Dow, CS
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2000, 69 (03) : 336 - 341