Evaluation of linear and nonlinear tomosynthetic reconstruction methods in digital mammography

被引:76
作者
Suryanarayanan, S
Karellas, A
Vedantham, S
Baker, SP
Glick, SJ
D'Orsi, CJ
Webber, RL
机构
[1] Univ Massachusetts, Sch Med, Dept Radiol, Worcester, MA 01655 USA
[2] Univ Massachusetts, Sch Med, Div Nucl Med, Worcester, MA 01655 USA
[3] Univ Massachusetts, Sch Med, Dept Acad Comp, Worcester, MA 01655 USA
[4] Univ Massachusetts, Mem Med Ctr, Worcester, MA 01605 USA
[5] Wake Forest Univ, Div Radiol Sci, Winston Salem, NC 27109 USA
关键词
breast cancer; digital imaging; mammography; TACT; tomosynthesis;
D O I
10.1016/S1076-6332(03)80530-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives. The purpose of this study was to comparatively evaluate digital planar mammography and both linear and nonlinear tomosynthetic reconstruction methods. Materials and Methods, A "disk" tie. target) identification study was conducted to compare planar and reconstruction methods, Projective data using a composite phantom with circular disks were acquired in both planar and tomographic modes by using a full-field, digital mammographic system. Two-dimensional projections were reconstructed with both linear tie, backprojection) and nonlinear tie. maximization and minimization) tuned-aperture computed tomographic (TACT) methods to produce three-dimensional data sets. Four board-certified radiologists and one 4th-year radiology resident participated as observers. All images were compared by these observers in terms of the number of disks identified. Results. Significant differences (P < .05, Bonferroni adjusted) were observed between all reconstruction and planar methods. No significant difference, however, was observed between the planar methods, and only a marginally significant difference (P < .054, Bonferroni adjusted) was observed between TACT-backprojection and TACT-minimization. Conclusion. A combination of linear and nonlinear reconstruction schemes may have potential implications in terms of enhancing image visualization to provide radiologists with valuable diagnostic information.
引用
收藏
页码:219 / 224
页数:6
相关论文
共 27 条
[1]  
Armitage P, 1987, Statistical methods in medical research, V2nd
[2]   DIGITIZED LONGITUDINAL TOMOGRAPHY [J].
BAILY, NA ;
KAMPP, TD .
INVESTIGATIVE RADIOLOGY, 1981, 16 (02) :126-132
[3]   Analysis of clustered microcalcifications by using a single numeric classifier extracted from mammographic digital images [J].
Buchbinder, SS ;
Leichter, IS ;
Bamberger, PN ;
Novak, B ;
Lederman, R ;
Fields, S ;
Behar, DJ .
ACADEMIC RADIOLOGY, 1998, 5 (11) :779-784
[4]   AN ANALYTIC APPROXIMATION TO THE DISTRIBUTION OF LILLIEFORS TEST STATISTIC FOR NORMALITY [J].
DALLAL, GE ;
WILKINSON, L .
AMERICAN STATISTICIAN, 1986, 40 (04) :294-296
[5]   3 DIMENSIONAL ROENTGENOGRAPHY [J].
GARRISON, JB ;
GRANT, DG ;
GUIER, WH ;
JOHNS, RJ .
AMERICAN JOURNAL OF ROENTGENOLOGY RADIUM THERAPY AND NUCLEAR MEDICINE, 1969, 105 (04) :903-&
[7]   Cancer statistics, 2000 [J].
Greenlee, RT ;
Murray, T ;
Bolden, S ;
Wingo, PA .
CA-A CANCER JOURNAL FOR CLINICIANS, 2000, 50 (01) :7-33
[8]   THE BACKPROJECTION METHOD APPLIED TO CLASSICAL TOMOGRAPHY [J].
KAMPP, TD .
MEDICAL PHYSICS, 1986, 13 (03) :329-333
[9]   CHARGE-COUPLED DEVICE DETECTOR - PERFORMANCE CONSIDERATIONS AND POTENTIAL FOR SMALL-FIELD MAMMOGRAPHIC IMAGING APPLICATIONS [J].
KARELLAS, A ;
HARRIS, LJ ;
LIU, H ;
DAVIS, MA ;
DORSI, CJ .
MEDICAL PHYSICS, 1992, 19 (04) :1015-1023
[10]  
Kirk R.E., 2012, EXPT DESIGN PROCEDUR, V4th