Suspected pediatric ingestions: Effectiveness of immunoassay screens vs. gas chromatography/mass spectroscopy in the detection of drugs and chemicals

被引:14
作者
Kyle, PB [1 ]
Spencer, JL [1 ]
Purser, CM [1 ]
Eddleman, KC [1 ]
Hume, AS [1 ]
机构
[1] Univ Mississippi, Med Ctr, Dept Pharmacol & Toxicol, Jackson, MS 39216 USA
来源
JOURNAL OF TOXICOLOGY-CLINICAL TOXICOLOGY | 2003年 / 41卷 / 07期
关键词
drugs; pediatrics; GC/MS; immunoassay;
D O I
10.1081/CLT-120026511
中图分类号
R99 [毒物学(毒理学)];
学科分类号
100405 ;
摘要
Rapid and accurate analytical testing can be of great value when determining treatment for pediatric patients suspected of ingesting an unknown chemical. Though often overlooked, gas chromatography/mass spectroscopy (GC/MS) can be a valuable resource in emergency toxicology testing. In a recent 24-month period (July 1999-June 2001), the Analytical Toxicology Laboratory at the University of Mississippi Medical Center, Jackson, MS, compared the results of GC/MS analysis to results obtained by immunoassay testing. The laboratory tested 139 urine samples referred for STAT toxicology testing from the hospital's Pediatric Emergency Department. All samples were tested in parallel using an immunoassay technique (EMIT(R)) and GC/MS. With analysis by immunoassay, 17.3% of the samples were positive for a drug of abuse. The number of positive drug classes ranged from 0 to 2 per sample (mean 0.17 +/- 0.43) using immunoassay. With analysis by GC/MS, drugs were detected in 88.5% of the samples. The number of drugs detected ranged from 0 to I I per sample (mean 2.2 +/- 1.8) with GC/MS. A total of 64 different pharmaceuticals were identified by GC/MS. This study shows that analysis by GC/MS offers the clinician a more comprehensive view into the exposure of the pediatric patient presenting with an unknown chemical ingestion.
引用
收藏
页码:919 / 925
页数:7
相关论文
共 27 条
[1]  
Bailey DN, 1996, AM J CLIN PATHOL, V105, P572
[2]   ANALYSIS OF URINARY BENZODIAZEPINES USING SOLID-PHASE EXTRACTION AND GAS-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
BLACK, DA ;
CLARK, GD ;
HAVER, VM ;
GARBIN, JA ;
SAXON, AJ .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1994, 18 (04) :185-188
[3]  
Bond G. Randall, 1995, Emergency Medicine Clinics of North America, V13, P343
[4]  
CANTROU PG, 1996, AM J CLIN PATHOL, V105, P527
[5]  
CHEN XH, 1992, J FORENSIC SCI, V37, P61
[6]  
FAZEN LE, 1986, PEDIATRICS, V77, P144
[7]  
FLANAGAN RJ, 1981, LANCET SEP, P682
[8]   Toxicity of over-the-counter cough and cold medications [J].
Gunn, VL ;
Taha, SH ;
Liebelt, EL ;
Serwint, JR .
PEDIATRICS, 2001, 108 (03) :E52
[9]  
HEPLER B, 1986, PEDIATR CLIN N AM, V33, P245
[10]   THE DECOMPOSITION OF BENZODIAZEPINES DURING ANALYSIS BY CAPILLARY GAS-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
JOYCE, JR ;
BAL, TS ;
ARDREY, RE ;
STEVENS, HM ;
MOFFAT, AC .
BIOMEDICAL MASS SPECTROMETRY, 1984, 11 (06) :284-289