MRI-Based Attenuation Correction for Whole-Body PET/MRI: Quantitative Evaluation of Segmentation- and Atlas-Based Methods

被引:230
作者
Hofmann, Matthias [1 ,2 ,3 ]
Bezrukov, Ilja [1 ,2 ]
Mantlik, Frederic [1 ,2 ]
Aschoff, Philip [4 ]
Steinke, Florian [2 ]
Beyer, Thomas [5 ]
Pichler, Bernd J. [1 ]
Schoelkopf, Bernhard [2 ]
机构
[1] Univ Tubingen, Dept Preclin Imaging & Radiopharm, Lab Preclin Imaging & Imaging Technol, Werner Siemens Fdn, D-72076 Tubingen, Germany
[2] Max Planck Inst Intelligent Syst, Dept Empir Inference, Tubingen, Germany
[3] Univ Oxford, Dept Engn Sci, Oxford OX1 3PJ, England
[4] Univ Tubingen, Dept Diagnost & Intervent Radiol, D-72076 Tubingen, Germany
[5] Imaging Sci Inst, Tubingen, Germany
关键词
attenuation correction; PET/MRI; quantitative imaging; segmentation; atlas; LUNG; PET/CT;
D O I
10.2967/jnumed.110.078949
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PET/MRI is an emerging dual-modality imaging technology that requires new approaches to PET attenuation correction (AC). We assessed 2 algorithms for whole-body MRI-based AC (MRAC): a basic MR image segmentation algorithm and a method based on atlas registration and pattern recognition (AT&PR). Methods: Eleven patients each underwent a whole-body PET/CT study and a separate multibed whole-body MRI study. The MR image segmentation algorithm uses a combination of image thresholds, Dixon fat-water segmentation, and component analysis to detect the lungs. MR images are segmented into 5 tissue classes (not including bone), and each class is assigned a default linear attenuation value. The AT&PR algorithm uses a database of previously aligned pairs of MRI/CT image volumes. For each patient, these pairs are registered to the patient MRI volume, and machine-learning techniques are used to predict attenuation values on a continuous scale. MRAC methods are compared via the quantitative analysis of AC PET images using volumes of interest in normal organs and on lesions. We assume the PET/CT values after CT-based AC to be the reference standard. Results: In regions of normal physiologic uptake, the average error of the mean standardized uptake value was 14.1% +/- 10.2% and 7.7% +/- 8.4% for the segmentation and the AT&PR methods, respectively. Lesion-based errors were 7.5% +/- 7.9% for the segmentation method and 5.7% +/- 4.7% for the AT&PR method. Conclusion: The MRAC method using AT&PR provided better overall PET quantification accuracy than the basic MR image segmentation approach. This better quantification was due to the significantly reduced volume of errors made regarding volumes of interest within or near bones and the slightly reduced volume of errors made regarding areas outside the lungs.
引用
收藏
页码:1392 / 1399
页数:8
相关论文
共 29 条
[1]   MULTISLICE, BREATHHOLD IMAGING OF THE LUNG WITH SUBMILLISECOND ECHO TIMES [J].
ALSOP, DC ;
HATABU, H ;
BONNET, M ;
LISTERUD, J ;
GEFTER, W .
MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (05) :678-682
[2]   Combined PET/MRI: a new dimension in whole-body oncology imaging? [J].
Antoch, Gerald ;
Bockisch, Andreas .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2009, 36 :113-120
[3]   MR-based attenuation correction for torso-PET/MR imaging:: pitfalls in mapping MR to CT data [J].
Beyer, Thomas ;
Weigert, Markus ;
Quick, Harald H. ;
Pietrzyk, Uwe ;
Vogt, Florian ;
Palm, Christoph ;
Antoch, Gerald ;
Mueller, Stefan P. ;
Bockisch, Andreas .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2008, 35 (06) :1142-1146
[4]  
Brechtel K, 2006, J NUCL MED, V47, P470
[5]   Toward Implementing an MRI-Based PET Attenuation-Correction Method for Neurologic Studies on the MR-PET Brain Prototype [J].
Catana, Ciprian ;
van der Kouwe, Andre ;
Benner, Thomas ;
Michel, Christian J. ;
Hamm, Michael ;
Fenchel, Matthias ;
Fischl, Bruce ;
Rosen, Bruce ;
Schmand, Matthias ;
Sorensen, A. Gregory .
JOURNAL OF NUCLEAR MEDICINE, 2010, 51 (09) :1431-1438
[6]  
Chefd'hotel C, 2002, 2002 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING, PROCEEDINGS, P753
[7]   Evaluation of the attenuation properties of MR equipment for its use in a whole-body PET/MR scanner [J].
Delso, G. ;
Martinez-Moeller, A. ;
Bundschuh, R. A. ;
Ladebeck, R. ;
Candidus, Y. ;
Faul, D. ;
Ziegler, S. I. .
PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (15) :4361-4374
[8]   SIMPLE PROTON SPECTROSCOPIC IMAGING [J].
DIXON, WT .
RADIOLOGY, 1984, 153 (01) :189-194
[9]  
Halpern BS, 2004, J NUCL MED, V45, P290
[10]   MRI-Based Attenuation Correction for PET/MRI: A Novel Approach Combining Pattern Recognition and Atlas Registration [J].
Hofmann, Matthias ;
Steinke, Florian ;
Scheel, Verena ;
Charpiat, Guillaume ;
Farquhar, Jason ;
Aschoff, Philip ;
Brady, Michael ;
Schoelkopf, Bernhard ;
Pichler, Bernd J. .
JOURNAL OF NUCLEAR MEDICINE, 2008, 49 (11) :1875-1883