Multimodality imaging in transcatheter aortic valve implantation: key steps to assess procedural feasibility

被引:48
作者
Delgado, Victoria [1 ]
Ewe, See Hooi [1 ]
Ng, Arnold C. T. [1 ]
van der Kley, Frank [1 ]
Marsan, Nina Ajmone [1 ]
Schuijf, Joanne D. [1 ]
Schalij, Martin J. [1 ]
Bax, Jeroen J. [1 ]
机构
[1] Leiden Univ, Med Ctr, Dept Cardiol, NL-2333 ZA Leiden, Netherlands
关键词
Transcatheter aortic valve implantation; multi-detector row computed tomography; aortic stenosis; MULTISLICE COMPUTED-TOMOGRAPHY; EXPANDING COREVALVE PROSTHESIS; MAGNETIC-RESONANCE; NONINVASIVE EVALUATION; ARTERY-DISEASE; STENOSIS; ROOT; REPLACEMENT; ECHOCARDIOGRAPHY; ANGIOGRAPHY;
D O I
10.4244/EIJV6I5A107
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Transcatheter aortic valve implantation (TAVI) has been an important breakthrough in the treatment of patients with symptomatic, severe aortic stenosis and contraindications for surgical aortic valve replacement. Accurate aortic root measurements and evaluation of spatial relationships with the coronary ostia are crucial in pre-operative TAVI assessment. In addition, characterisation of the peripheral artery anatomy and aorta is an important key step in the procedural feasibility evaluation. The present review article provides a practical approach, based on multimodality imaging, to select candidates for TAVI and to evaluate the procedural feasibility.
引用
收藏
页码:643 / 652
页数:10
相关论文
共 37 条
[1]   Aortic root morphology in patients undergoing percutaneous aortic valve replacement: Evidence of aortic root remodeling [J].
Akhtar, Mateen ;
Tuzcu, E. Murat ;
Kapadia, Samir R. ;
Svensson, Lars G. ;
Greenberg, Roy K. ;
Roselli, Eric E. ;
Halliburton, Sandra ;
Kurra, Vikram ;
Schoenhagen, Paul ;
Sola, Srikanth .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2009, 137 (04) :950-956
[2]   Aortic Root Measurement by Cardiovascular Magnetic Resonance Specification of Planes and Lines of Measurement and Corresponding Normal Values [J].
Burman, Elisabeth D. ;
Keegan, Jennifer ;
Kilner, Philip J. .
CIRCULATION-CARDIOVASCULAR IMAGING, 2008, 1 (02) :104-113
[3]   Echocardiography for transcatheter aortic valve implantation [J].
Chin, Derek .
EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2009, 10 (01) :I21-I29
[4]   Comparison of the Hemodynamic Performance of Percutaneous and Surgical Bioprostheses for the Treatment of Severe Aortic Stenosis [J].
Clavel, Marie-Annick ;
Webb, John G. ;
Pibarot, Philippe ;
Altwegg, Lukas ;
Dumont, Eric ;
Thompson, Chris ;
De Larochelliere, Robert ;
Doyle, Daniel ;
Masson, Jean-Bernard ;
Bergeron, Sebastien ;
Bertrand, Olivier F. ;
Rodes-Cabau, Josep .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 53 (20) :1883-1891
[5]   Early experience with percutaneous transcatheter implantation of heart valve prosthesis for the treatment of end-stage inoperable patients with calcific aortic stenosis [J].
Cribier, A ;
Eltchaninoff, H ;
Tron, C ;
Bauer, F ;
Agatiello, C ;
Sebagh, L ;
Bash, A ;
Nusimovici, D ;
Litzler, PY ;
Bessou, JP ;
Leon, MB .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (04) :698-703
[6]  
Delgado Victoria, 2010, Expert Rev Cardiovasc Ther, V8, P113, DOI 10.1586/erc.09.135
[7]  
Delgado Victoria, 2009, Circ Cardiovasc Imaging, V2, pe12, DOI 10.1161/CIRCIMAGING.108.809434
[8]   Transcatheter aortic valve implantation: role of multi-detector row computed tomography to evaluate prosthesis positioning and deployment in relation to valve function [J].
Delgado, Victoria ;
Ng, Arnold C. T. ;
van de Veire, Nico R. ;
van der Kley, Frank ;
Schuijf, Joanne D. ;
Tops, Laurens F. ;
de Weger, Arend ;
Tavilla, Giuseppe ;
de Roos, Albert ;
Kroft, Lucia J. ;
Schalij, Martin J. ;
Bax, Jeroen J. .
EUROPEAN HEART JOURNAL, 2010, 31 (09) :1114-1123
[9]   Aorto-iliac angiography as a screening tool in selecting patients for transfemoral aortic valve implantation with the Edwards SAPIEN bioprosthesis [J].
Eltchaninoff, Helene ;
Kerkeni, Mehdi ;
Zajarias, Alan ;
Tron, Christophe ;
Godin, Matthieu ;
Giron, Carlos Sanchez ;
Baala, Brahim ;
Cribier, Alain .
EUROINTERVENTION, 2009, 5 (04) :438-442
[10]   Percutaneous aortic valve replacement for severe aortic stenosis in high-rick patients using the second- and current third-generation self-expanding CoreValve prosthesis - Device success and 30-day clinical outcome [J].
Grube, Eberhard ;
Schuler, Gerhard ;
Buellesfeld, Lutz ;
Gerckens, Ulrich ;
Linke, Axel ;
Wenaweser, Peter ;
Sauren, Barthel ;
Mohr, Friedrich-Wilhelm ;
Walther, Thomas ;
Zickmann, Bernfried ;
Iversen, Stein ;
Felderhoff, Thomas ;
Cartier, Raymond ;
Bonan, Raoul .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 50 (01) :69-76