Direct electron transfer between cytochrome P450scc and gold nanoparticles on screen-printed rhodium-graphite electrodes

被引:87
作者
Shumyantseva, VV
Carrara, S
Bavastrello, V
Riley, DJ
Bulko, TV
Skryabin, KG
Archakov, AI
Nicolini, C
机构
[1] Univ Genoa, Dep DISTBIMO, I-16132 Genoa, Italy
[2] Inst Biomed Chem, Moscow 119121, Russia
[3] Fdn ELBA, Rome, Italy
[4] Univ Genoa, CIRNNOB, Nanoworld Inst, I-16132 Genoa, Italy
[5] Univ Bristol, Sch Chem, Bristol BS8 1TS, Avon, England
[6] Ctr Bioengn, Moscow 117312, Russia
关键词
electron transfer; cytochrome; gold nanoparticles; cholesterol; biosensors; screen-printed;
D O I
10.1016/j.bios.2004.10.008
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
This paper is concerned with an investigation of electron transfer between cytochrome P450scc (CYP11A1) and gold nanoparticles immobilised on rhodium-graphite electrodes. Thin films of gold nanoparticles were deposited onto the rhodium-graphite electrodes by drop casting. Cytochrome P450scc was deposited onto both gold nanoparticle modified and bare rhodium-graphite electrodes. Cyclic voltammetry indicated enhanced activity of the enzyme at the gold naroparticle modified surface. The role of the nanoparticles in mediating electron transfer to the cytochrome P450scc was verified using ac impedance spectroscopy. Equivalent circuit analysis of the impedance spectra was performed and the values of the individual components estimated. On addition of aliquots of cholesterol to the electrolyte bioelectrocatalytic reduction currents were obtained. The sensitivity of the nanoparticle modified biosensor to cholesterol was 0. 13 mu A mu M-1 in a detection range between 10 and 70 mu M of cholesterol. This confirms that gold nanoparticles enhance electron transfer to the P450scc when present on the rhodium-graphite electrodes. (c) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:217 / 222
页数:6
相关论文
共 29 条
[1]   Recent developments in faradaic bioelectrochemistry [J].
Armstrong, FA ;
Wilson, GS .
ELECTROCHIMICA ACTA, 2000, 45 (15-16) :2623-2645
[2]   A disposable multielectrode biosensor for rapid simultaneous detection of the insecticides paraoxon and carbofuran at high resolution [J].
Bachmann, TT ;
Schmid, RD .
ANALYTICA CHIMICA ACTA, 1999, 401 (1-2) :95-103
[3]   Improved multianalyte detection of organophosphates and carbamates with disposable multielectrode biosensors using recombinant mutants of Drosophila acetylcholinesterase and artificial neural networks [J].
Bachmann, TT ;
Leca, B ;
Vilatte, F ;
Marty, JL ;
Fournier, D ;
Schmid, RD .
BIOSENSORS & BIOELECTRONICS, 2000, 15 (3-4) :193-201
[4]  
Berthell D., 1996, J ELECTROANAL CHEM, V409, P137
[5]   Morphology-dependent electrochemistry of cytochrome c at Au colloid-modified SnO2 electrodes [J].
Brown, KR ;
Fox, AP ;
Natan, MJ .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1996, 118 (05) :1154-1157
[6]   A new way of using ac voltammetry to study redox kinetics in electroactive monolayers [J].
Creager, SE ;
Wooster, TT .
ANALYTICAL CHEMISTRY, 1998, 70 (20) :4257-4263
[7]   Application of electrochemistry for P450-catalyzed reactions [J].
Estabrook, RW ;
Faulkner, KM ;
Shet, MS ;
Fisher, CW .
CYTOCHROME P450, PT B, 1996, 272 :44-51
[8]   Roughened silver electrodes for use in metal-enhanced fluorescence [J].
Geddes, CD ;
Parfenov, A ;
Roll, D ;
Gryezynski, I ;
Malicka, J ;
Lakowicz, JR .
SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2004, 60 (8-9) :1977-1983
[9]   A 1.4-NM GOLD CLUSTER COVALENTLY ATTACHED TO ANTIBODIES IMPROVES IMMUNOLABELING [J].
HAINFELD, JF ;
FURUYA, FR .
JOURNAL OF HISTOCHEMISTRY & CYTOCHEMISTRY, 1992, 40 (02) :177-184
[10]   Direct electron transfer between hemoglobin and a glassy carbon electrode facilitated by lipid-protected gold nanoparticles [J].
Han, XJ ;
Cheng, WL ;
Zhang, ZL ;
Dong, SJ ;
Wang, EK .
BIOCHIMICA ET BIOPHYSICA ACTA-BIOENERGETICS, 2002, 1556 (2-3) :273-277