Influences of biofluid sample collection and handling procedures on GC-MS based metabolomic studies

被引:50
作者
Bando, Kiyoko [1 ,2 ]
Kawahara, Rui [1 ]
Kunimatsu, Takeshi [2 ]
Sakai, Jun [3 ]
Kimura, Juki [2 ]
Funabashi, Hitoshi [2 ]
Seki, Takaki [2 ]
Bamba, Takeshi [1 ]
Fukusaki, Eiichiro [1 ]
机构
[1] Osaka Univ, Grad Sch Engn, Dept Biotechnol, Osaka 5650871, Japan
[2] Dainippon Sumitomo Pharm Co Ltd, Safety Res Labs, Konohana Ku, Osaka 5540022, Japan
[3] Dainippon Sumitomo Pharm Co Ltd, Genom Sci Labs, Konohana Ku, Osaka 5540022, Japan
关键词
Metabolomics; Urine; Plasma; Sample collection; GC-MS; CLINICAL PATHOLOGY PARAMETERS; MASS-SPECTROMETRY; DIURNAL-VARIATION; FISCHER-344; RATS; SITE; ANTICOAGULANT; MAMMALS; HEPARIN; URINE; BLOOD;
D O I
10.1016/j.jbiosc.2010.04.010
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Sample collection procedures of pharmacology and toxicology studies might have a great impact on interpretation of metabolomic study results. Characterization of range variation among sample collection methods is necessary to prevent misinterpretation, as is use of optimal methods in animal experiments to minimize biological/technical variation. Here, we investigated the influence of urine and plasma sample collection and handling procedures on GC-MS based metabolomic studies as follows: for urine, pooling period and tube conditions during collection; for plasma, sampling sites, anesthesia and anticoagulants. Metabolic profiles of urine varied dramatically depending on urine pooling period and tube conditions, underscoring the importance of determining appropriate sampling periods in consideration of diurnal effects and targets of effect/toxicity, and suggesting it would be preferable to keep tubes in metabolic cages under iced conditions for urine sampling. Metabolic profiles of plasma differed depending on blood sampling sites. Anesthesia was not effective in reducing individual variation, although the anesthesia was beneficial in reducing discomfort in rats. In GC-MS based metabolomic studies, we recommend that EDTA be used as anticoagulant in plasma sample preparation, because peaks derived from heparin might overlap with endogenous metabolites, which may induce inter-sample variation. The present study demonstrated that biofluid sample collection and handling procedures provide great impact on metabolic profiles, at the very least for minimizing biological/technical variation, sampling period for urine collection should not be set as a short period, and the use of EDTA is recommended as anticoagulant in preparing plasma for analysis by GC-MS. (C) 2010, The Society for Biotechnology, Japan. All rights reserved.
引用
收藏
页码:491 / 499
页数:9
相关论文
共 29 条
[1]   EFFECT OF STRESS AND NEMBUTAL ON PLASMA LEVELS OF GONADOTROPINS AND PROLACTIN IN OVARIECTOMIZED RATS [J].
AJIKA, K ;
MCCANN, SM ;
KALRA, SP ;
FAWCETT, CP ;
KRULICH, L .
ENDOCRINOLOGY, 1972, 90 (03) :707-&
[2]   The role of ethylenedimine tetraacetic acid (EDTA) as in vitro anticoagulant for diagnostic purposes [J].
Banfi, Giuseppe ;
Salvagno, Gian Luca ;
Lippi, Giuseppe .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2007, 45 (05) :565-576
[3]   STRUCTURAL-ANALYSIS OF HEPARIN BY METHYLATION AND GLC-MS - PRELIMINARY-RESULTS [J].
BARKER, SA ;
HURST, RE ;
SETTINE, J ;
FISH, FP ;
SETTINE, RL .
CARBOHYDRATE RESEARCH, 1984, 125 (02) :291-300
[4]   EFFECT OF AGING AND DIET ON PROTON NMR-SPECTRA OF RAT URINE [J].
BELL, JD ;
SADLER, PJ ;
MORRIS, VC ;
LEVANDER, OA .
MAGNETIC RESONANCE IN MEDICINE, 1991, 17 (02) :414-422
[5]   Potential of metabolomics as a functional genomics tool [J].
Bino, RJ ;
Hall, RD ;
Fiehn, O ;
Kopka, J ;
Saito, K ;
Draper, J ;
Nikolau, BJ ;
Mendes, P ;
Roessner-Tunali, U ;
Beale, MH ;
Trethewey, RN ;
Lange, BM ;
Wurtele, ES ;
Sumner, LW .
TRENDS IN PLANT SCIENCE, 2004, 9 (09) :418-425
[6]   MECHANISM OF THE ANTICOAGULANT ACTION OF HEPARIN [J].
BJORK, I ;
LINDAHL, U .
MOLECULAR AND CELLULAR BIOCHEMISTRY, 1982, 48 (03) :161-182
[7]   NMR-based metabonomic approaches for evaluating physiological influences on biofluid composition [J].
Bollard, ME ;
Stanley, EG ;
Lindon, JC ;
Nicholson, JK ;
Holmes, E .
NMR IN BIOMEDICINE, 2005, 18 (03) :143-162
[8]   Investigations into biochemical changes due to diurnal variation and estrus cycle in female rats using high-resolution 1H NMR spectroscopy of urine and pattern recognition [J].
Bollard, ME ;
Holmes, E ;
Lindon, JC ;
Mitchell, SC ;
Branstetter, D ;
Zhang, W ;
Nicholson, JK .
ANALYTICAL BIOCHEMISTRY, 2001, 295 (02) :194-202
[9]   Mass spectrometry in the clinical laboratory [J].
Chace, DH .
CHEMICAL REVIEWS, 2001, 101 (02) :445-477
[10]  
DAMERON GW, 1992, LAB ANIM SCI, V42, P299