Smart suction device for less blood trauma: a comparison with Cell Saver

被引:18
作者
Mueller, XH [1 ]
Tevaearai, HT
Horisberger, J
Augstburger, M
Boone, Y
von Segesser, LK
机构
[1] CHU Vaudois, Cardiovasc Surg Clin, CH-1011 Lausanne, Switzerland
[2] CHU Vaudois, Surg Intens Care Unit, CH-1011 Lausanne, Switzerland
关键词
cardiopulmonary bypass; hemolysis; blood; suction;
D O I
10.1016/S1010-7940(01)00630-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective. The major source of hemolysis during cardiopulmonary bypass remains the cardiotomy suction and is primarily due to the interaction between air and blood. The Smart suction system involves an automatically controlled aspiration designed to avoid the mixture of blood with air. This study was set-tip to compare this recently designed suction system to a Cell Saver system in order to investigate their effects on blood elements during prolonged intrathoracic aspiration. Methods: In a calf model (n = 10; mean weight, 69.3 +/- 4.5 kg), a standardized hole was created in the right atrium allowing a blood loss of 100 ml/min, with a suction cannula placed into the chest cavity into a fixed position during 6 h. The blond was continuously aspirated either with the Smart suction system (five animals) or the Cell Saver system (five animals). Blood samples were taken hourly for blood cell counts and biochemistry. Results: In the Smart suction group, red cell count, plasma protein and free hemoglobin levers remained stable, while platelet count exhibited a significant drop from the fifth hour onwards (prebypass: 683 +/- 201*10(9)/l. 5 h: 230 +/- I42*10(9)/l, P = 0.046). In the Cell Saver group, there was a significant drop of the red cell count from the third hour onwards (prebypass: 8.6 +/- 0.9*10(12)/l, 6 h: 6.3 +/- 0.4*10(12)/l, P = 0.02), of the platelet count from the first hom onwards (prebypass: 630 +/- 97*10(9)/l, 1 h: 224 +/- 75*10(9)/l, P < 0.01), and of the plasma protein level from the first hour onwards (prebypass: 61.7 +/- 0.6 g/l, 1 h: 29.3 +/- 9.1 g/l, P < 0.01). Conclusions: In this experimental set-up, the Smart suction system avoids damage to red cells and affects platelet count less than the Cell Saver system which induces important blood cell destruction, as any suction device mixing air and blood, as well as severe hypoproteinemia with its metabolic, clotting and hemodynamic consequences. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:507 / 511
页数:5
相关论文
共 19 条
[1]  
*AM ASS BLOOD BANK, 1993, GUID BLOOD SALV REIN
[2]  
ANSELL J, 1982, J THORAC CARDIOV SUR, V84, P387
[3]  
BOONSTRA PW, 1985, J THORAC CARDIOV SUR, V89, P900
[4]  
DEJONG JCF, 1980, J THORAC CARDIOV SUR, V79, P227
[5]   ROLE OF AUTOGENOUS TISSUE FACTORS IN HEMOLYSIS DURING CARDIOPULMONARY BYPASS OPERATIONS [J].
FORD, EG ;
PICONE, AL ;
BAISDEN, CE .
ANNALS OF THORACIC SURGERY, 1993, 55 (02) :410-412
[6]   Suction-induced hemolysis at various vacuum pressures: Implications for intraoperative blood salvage [J].
Gregoretti, S .
TRANSFUSION, 1996, 36 (01) :57-60
[7]   Cell saver autologous transfusion: Metabolic consequences of washing blood with normal saline [J].
Halpern, NA ;
Alicea, M ;
Seabrook, B ;
Spungen, AM ;
McElhinney, AJ ;
Greenstein, RJ .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1996, 41 (03) :407-415
[8]  
INDEGLIA RA, 1967, SURGERY, V62, P47
[9]  
KEITH HB, 1981, J THORAC SURG, V41, P404
[10]   24-HOUR SURVIVAL OF AUTOTRANSFUSED RED-CELLS IN ELECTIVE AORTIC-SURGERY - A COMPARISON OF 2 INTRAOPERATIVE AUTOTRANSFUSION SYSTEMS [J].
KENT, P ;
ASHLEY, S ;
THORLEY, PJ ;
SHAW, A ;
PARKIN, A ;
KESTER, RC .
BRITISH JOURNAL OF SURGERY, 1991, 78 (12) :1473-1475