Prevention of pocket related complications with fibrin sealant in patients undergoing pacemaker implantation who are receiving anticoagulant treatment

被引:37
作者
Milic, DJ
Perisic, ZD
Zivic, SS
Stanojkovic, ZA
Stojkovic, AM
Karanovic, ND
Krstic, NH
Salinger, SS
机构
[1] Surg Clin, Ctr Clin, Vasc Dept, Nish 18000, Serbia Monteneg
[2] Ctr Clin, Clin Cardiovasc Dis, Pacemaker Ctr, Nish 18000, Serbia Monteneg
[3] Inst Blood Transfus, Nish 18000, Serbia Monteneg
来源
EUROPACE | 2005年 / 7卷 / 04期
关键词
fibrin sealant; pacemaker; implantation; complications; pocket haematoma;
D O I
10.1016/j.eupc.2005.03.007
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aim The aim of our study was to establish the efficiency of fibrin sealant in the prevention of pocket related complications in patients undergoing pacemaker implantation who are receiving anticoagulant treatment. Methods The study was performed on 40 and 41 patients prospectively randomized into treatment and control groups who underwent pacemaker implantation procedure between January 2002 and July 2004 at the Pacemaker Center - Clinical Centre Nis, Serbia. Both groups of patients were receiving anticoagulant treatment with either heparin or warfarin. Surgical procedures between the groups differed only in the application of fibrin sealant prior to wound closure in the treatment group. Results In the treatment group, there were no pocket related complications while in the control group six patients (14.63%) had minor haematomas that required no treatment. Four patients (9.76%) had significant haematomas (two patients were treated conservatively while the other two needed reintervention). The INR in the -,,treatment group was 2.76 +/- 0.85 and in the control group 2.65 +/- 0.79 (P = ns). In the follow-up period (2-27 months) no late complications were registered in either group. Conclusion Fibrin sealant is an effective haemostatic agent. The results obtained in our study show that the administration of fibrin sealant in 'patients receiving anticoagulant treatment eliminates postoperative haematomas after pacemaker implantation.(c) 2005 The European Society of Cardiology. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:374 / 379
页数:6
相关论文
共 25 条
[1]   Implantation of pacemakers and implantable cardioverter defibrillators in orally anticoagulated patients [J].
Al-Khadra, AS .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2003, 26 (01) :511-514
[2]   ANTITHROMBOTIC THERAPY - AN ABBREVIATED REFERENCE FOR CLINICIAN [J].
BECKER, RC ;
ANSELL, J .
ARCHIVES OF INTERNAL MEDICINE, 1995, 155 (02) :149-161
[3]   The effects of fibrin [J].
Bergel, S .
DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 1909, 35 :663-665
[4]   PACEMAKER INFECTIONS - A 2-YEAR FOLLOW-UP OF ANTIBIOTIC-PROPHYLAXIS [J].
BLUHM, GL .
SCANDINAVIAN JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1985, 19 (03) :231-235
[5]   Pacemaker infective endocarditis [J].
Cacoub, P ;
Leprince, P ;
Nataf, P ;
Hausfater, P ;
Dorent, R ;
Wechsler, B ;
Bors, V ;
Pavie, A ;
Piette, JC ;
Gandjbakhch, I .
AMERICAN JOURNAL OF CARDIOLOGY, 1998, 82 (04) :480-484
[6]   THROMBOEMBOLIC AND BLEEDING COMPLICATIONS IN PATIENTS WITH MECHANICAL HEART-VALVE PROSTHESES [J].
CANNEGIETER, SC ;
ROSENDAAL, FR ;
BRIET, E .
CIRCULATION, 1994, 89 (02) :635-641
[7]  
CASTBERG T, 1976, ACTA MED SCAND, P51
[8]   EARLY COMPLICATIONS AFTER DUAL-CHAMBER VERSUS SINGLE CHAMBER PACEMAKER IMPLANTATION [J].
CHAUHAN, A ;
GRACE, AA ;
NEWELL, SA ;
STONE, DL ;
SHAPIRO, LM ;
SCHOFIELD, PM ;
PETCH, MC .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1994, 17 (11) :2012-2015
[9]  
DRESDALE A, 1985, SURGERY, V97, P750
[10]  
Gdanietz K., 1991, ACTA CHIR AUSTRIACA, V23, P95