Development of a fluorescent ligand-binding assay using the AcroWell filter plate

被引:14
作者
Valenzano, KJ
Miller, W
Kravitz, JN
Samama, P
Fitzpatrick, D
Seeley, K
机构
[1] Pall Gelman Lab, Sci & Lab Serv, Ann Arbor, MI 48103 USA
[2] Pharmacopeia Inc, Princeton, NJ USA
关键词
D O I
10.1177/108705710000500608
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
One of the most powerful tools for receptor research and drug discovery is the use of receptor-ligand affinity screening of combinatorial libraries. Early work involved the use of radioactive ligands to identify a binding event; however, there are numerous limitations involved in the use of radioactivity for high throughput screening, These limitations have led to the creation of highly sensitive, nonradioactive alternatives to investigate receptor-ligand interactions. Pall Gelman Laboratory has introduced the AcroWell, a patented low-fluorescent-background membrane and sealing process together with a filter plate design that is compatible with robotic systems. Taken together, these allow the AcroWell 96-well filter plate to detect trace quantities of lanthanide-labeled ligands for cell-, bead-, or membrane-based assays using time-resolved fluorescence, Using europium-labeled galanin, we have demonstrated that saturation binding experiments can be performed with low-background fluorescence and signal-to-noise ratios that rival traditional radioisotopic techniques while maintaining biological integrity of the receptor-ligand interaction, In addition, the ability to discriminate between active and inactive compounds in a mock galanin screen is demonstrated with low well-to-well variability, allowing reliable determination of positive hits even for low-affinity interactions.
引用
收藏
页码:455 / 461
页数:7
相关论文
共 8 条
[1]   Biological characterization of neurokinin antagonists discovered through screening of a combinatorial library [J].
Appell, KC ;
Chung, TDY ;
Solly, KJ ;
Chelsky, D .
JOURNAL OF BIOMOLECULAR SCREENING, 1998, 3 (01) :19-27
[2]   MOLECULAR-CLONING OF A FUNCTIONAL HUMAN GALANIN RECEPTOR [J].
HABERTORTOLI, E ;
AMIRANOFF, B ;
LOQUET, I ;
LABURTHE, M ;
MAYAUX, JF .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1994, 91 (21) :9780-9783
[3]   Time-resolved fluorometry: an overview of the labels and core technologies for drug screening applications [J].
Hemmila, I ;
Webb, S .
DRUG DISCOVERY TODAY, 1997, 2 (09) :373-381
[4]   THE HUMAN GALANIN RECEPTOR - LIGAND-BINDING AND FUNCTIONAL-CHARACTERISTICS IN THE BOWES MELANOMA CELL-LINE [J].
HEUILLET, E ;
BOUAICHE, Z ;
MENAGER, J ;
DUGAY, P ;
MUNOZ, N ;
DUBOIS, H ;
AMIRANOFF, B ;
CRESPO, A ;
LAVAYRE, J ;
BLANCHARD, JC ;
DOBLE, A .
EUROPEAN JOURNAL OF PHARMACOLOGY-MOLECULAR PHARMACOLOGY SECTION, 1994, 269 (02) :139-147
[5]   Chemokine receptor-ligand interactions measured using time-resolved fluorescence [J].
Inglese, J ;
Samama, P ;
Patel, S ;
Burbaum, J ;
Stroke, IL ;
Appell, KC .
BIOCHEMISTRY, 1998, 37 (08) :2372-2377
[6]   A time-resolved fluorometric assay for galanin receptors [J].
Liu, J ;
Gallagher, M ;
Horlick, RA ;
Robbins, AK ;
Webb, ML .
JOURNAL OF BIOMOLECULAR SCREENING, 1998, 3 (03) :199-206
[7]   Light on high-throughput screening: Fluorescence-based assay technologies [J].
Rogers, MV .
DRUG DISCOVERY TODAY, 1997, 2 (04) :156-160
[8]   A simple statistical parameter for use in evaluation and validation of high throughput screening assays [J].
Zhang, JH ;
Chung, TDY ;
Oldenburg, KR .
JOURNAL OF BIOMOLECULAR SCREENING, 1999, 4 (02) :67-73