Quantification of renal blood flow with contrast-enhanced ultrasound

被引:242
作者
Wei, K
Le, E
Bin, JP
Coggins, M
Thorpe, J
Kaul, S
机构
[1] Univ Virginia, Sch Med, Div Cardiovasc, Charlottesville, VA 22908 USA
[2] Univ Virginia, Sch Med, Cardiac Imaging Ctr, Charlottesville, VA 22908 USA
关键词
D O I
10.1016/S0735-1097(00)01210-9
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES The goal of this study was to determine the ability of contrast-enhanced ultrasound (CEU) to quantify renal tissue perfusion. BACKGROUND The kinetics of tracers used to assess renal perfusion are often complicated by countercurrent exchange, tubular transport or glomerular filtration. We hypothesized that, because gas-filled microbubbles are pure intravascular tracers with a rheology similar to that of red blood cells, CEU could be used to quantify renal tissue perfusion. METHODS During a continuous venous infusion of microbubbles (SonoVue), regional renal perfusion was quantified in nine dogs using CEU by destroying microbubbles and measuring their tissue replenishment with intermittent harmonic imaging. Both renal blood volume fraction and microbubble velocity were derived from pulsing interval versus video-intensity plots. The product of the two was used to calculate renal nutrient blood flow. Renal arterial blood flow was independently measured with ultrasonic flow probes placed directly on the renal artery and was increased using dopamine and decreased by placement of a renal artery stenosis. RESULTS An excellent correlation was found between cortical nutrient blood flow using microbubbles and ultrasonic flow probe-derived renal blood flow (r = 0.82, p < 0.001) over a wide range (2.5 fold) of flows. CONCLUSIONS Ultrasound examination during microbubble infusion can be used to quantify total organ as well as regional nutrient blood flow to the kidney. (J Am Coll Cardiol 2001;37:1135-40) (C) 2001 by the American College of Cardiology.
引用
收藏
页码:1135 / 1140
页数:6
相关论文
共 18 条
  • [1] ARONSON S, 1993, ANESTH ANALG, V76, P964
  • [2] METHODS FOR MEASURING RENAL BLOOD-FLOW - TOTAL FLOW AND REGIONAL DISTRIBUTION
    AUKLAND, K
    [J]. ANNUAL REVIEW OF PHYSIOLOGY, 1980, 42 : 543 - 555
  • [3] MEASUREMENT OF GLOMERULAR BLOOD-FLOW IN RABBITS AND RATS - ERRONEOUS FINDINGS WITH 15-MU-M MICROSPHERES
    BANKIR, L
    TRINHTRANGTAN, MM
    GRUNFELD, JP
    [J]. KIDNEY INTERNATIONAL, 1979, 15 (02) : 126 - 133
  • [4] MEASUREMENT OF RENAL PERFUSION AND BLOOD-FLOW WITH FAST COMPUTED-TOMOGRAPHY
    BENTLEY, MD
    LERMAN, LO
    HOFFMAN, EA
    FIKSENOLSEN, MJ
    RITMAN, EL
    ROMERO, JC
    [J]. CIRCULATION RESEARCH, 1994, 74 (05) : 945 - 951
  • [5] Renovascular disease and renal in sufficiency - Diagnosis and treatment
    Christensson, A
    [J]. SCANDINAVIAN JOURNAL OF UROLOGY AND NEPHROLOGY, 1999, 33 (06): : 400 - 405
  • [6] Fernandez P, 1999, J NUCL MED, V40, P412
  • [7] IN-VIVO MYOCARDIAL KINETICS OF AIR-FILLED ALBUMIN MICROBUBBLES DURING MYOCARDIAL CONTRAST ECHOCARDIOGRAPHY - COMPARISON WITH RADIOLABELED RED-BLOOD-CELLS
    JAYAWEERA, AR
    EDWARDS, N
    GLASHEEN, WP
    VILLANUEVA, FS
    ABBOTT, RD
    KAUL, S
    [J]. CIRCULATION RESEARCH, 1994, 74 (06) : 1157 - 1165
  • [8] THE BEHAVIOR OF SONICATED ALBUMIN MICROBUBBLES WITHIN THE MICROCIRCULATION - A BASIS FOR THEIR USE DURING MYOCARDIAL CONTRAST ECHOCARDIOGRAPHY
    KELLER, MW
    SEGAL, SS
    KAUL, S
    DULING, B
    [J]. CIRCULATION RESEARCH, 1989, 65 (02) : 458 - 467
  • [9] CONTRAST ULTRASONOGRAPHY OF THE KIDNEY - A NEW METHOD FOR EVALUATION OF RENAL PERFUSION INVIVO
    LANG, RM
    FEINSTEIN, SB
    POWSNER, SM
    MCCOY, CE
    FREDERICKSON, ED
    NEUMANN, A
    GOLDBERG, LI
    BOROW, KM
    [J]. CIRCULATION, 1987, 75 (01) : 229 - 234
  • [10] CARDIOVASCULAR AND RENAL HEMODYNAMIC-EFFECTS OF INTRAVENOUS INFUSIONS OF THE SELECTIVE DA1 AGONIST, FENOLDOPAM, USED ALONE OR IN COMBINATION WITH DOPAMINE AND DOBUTAMINE
    LASS, NA
    GLOCK, D
    GOLDBERG, LI
    [J]. CIRCULATION, 1988, 78 (05) : 1310 - 1315