Evaluation of the effect of three surface treatments on the biocompatibility of 316L stainless steel using human differentiated cells

被引:132
作者
Bordji, K
Jouzeau, EY
Mainard, D
Payan, E
Delagoutte, JP
Netter, P
机构
[1] FAC MED NANCY,PHARMACOL LAB,CNRS,URA 1288,F-54505 VANDOEUVRE NANCY,FRANCE
[2] CHU NANCY BRABOIS,INST EUROPEEN BIOMAT MICROCHIRURG,F-54511 VANDOEUVRE NANCY,FRANCE
关键词
orthopaedic prostheses; 316L stainless steel; surface treatments; biocompatibility; cell culture;
D O I
10.1016/0142-9612(96)82723-2
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
AISI 316L stainless steel (SS) is widely used in orthopaedic implantology, although biological complications may result from its insufficient mechanical and tribological properties. In order to improve the wear and corrosion resistance as well as the hardness of 316L SS, three surface treatments, derived from those applied in mechanical engineering industries, were investigated: (1) glow discharge nitrogen implantation, (2) carbon-doped stainless steel coating sputtering and (3) low temperature plasma nitriding. Surface characterization according to the different heat treatments showed that corrosion and wear resistance were strongly improved, especially by ion implantation or carbon-doped SS coating sputtering. In the same way, microhardness was significantly increased after the three treatments. The effect of such treatments on the biocompatibility of 316L SS was studied with human osteoblast and fibroblast cultures. Basic and specific features of the cells showed that ion-implanted and carbon-doped stainless steels were biocompatible, whereas dramatic cellular reactions were noted when contacted with nitrided stainless steel. A hypothesis is given to explain this observation but further experiments are needed to optimize the nitriding process. Nitrogen implantation and carbon-doped layer deposition could be efficient means for improving the physical properties of stainless steel without affecting its biocompatibility. Such surface treatments may have relevance for increasing the life time of 316L SS biomedical devices.
引用
收藏
页码:491 / 500
页数:10
相关论文
共 38 条
[1]  
BARBEE TW, 1979, THIN SOLID FILMS, V63, P143, DOI 10.1016/0040-6090(79)90115-9
[2]  
BESSEY OA, 1946, J BIOL CHEM, V164, P321
[3]   MECHANISMS OF CHROMIUM TOXICITY IN MAMMALIAN-CELL CULTURES [J].
BIANCHI, V ;
DALTOSO, R ;
DEBETTO, P ;
LEVIS, AG ;
LUCIANI, S ;
MAJONE, F ;
TAMINO, G .
TOXICOLOGY, 1980, 17 (02) :219-224
[4]  
BILLARD A, 1990, P 8 INT C THIN FILMS
[5]  
BORDSI K, UNPUB
[6]  
BRUNETTE D M, 1986, Critical Reviews in Biocompatibility, V1, P323
[8]  
COLEMAN RF, 1973, J BONE JOINT SURG BR, V55, P422
[9]   THE BONE TITANIUM INTERFACE INVITRO [J].
DAVIES, JE ;
LOWENBERG, B ;
SHIGA, A .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1990, 24 (10) :1289-1306
[10]   ION-IMPLANTATION AND ION ASSISTED COATING OF METALS [J].
DEARNALEY, G ;
GOODE, PD ;
MINTER, FJ ;
PEACOCK, AT ;
WADDELL, CN .
JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A-VACUUM SURFACES AND FILMS, 1985, 3 (06) :2684-2689