Assessment of left ventricular function by real-time 3-dimensional echocardiography compared with conventional noninvasive methods

被引:53
作者
Takuma, S [1 ]
Ota, T [1 ]
Muro, T [1 ]
Hozumi, T [1 ]
Sciacca, R [1 ]
Di Tullio, MR [1 ]
Blood, DK [1 ]
Yoshikawa, J [1 ]
Homma, S [1 ]
机构
[1] Columbia Univ, Dept Med, Div Cardiol, New York, NY USA
关键词
D O I
10.1067/mje.2001.111158
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Quantitative assessment of left ventricular ejection fraction is an essential component of cardiac evaluation. We performed real-time 3-dimensional echocardiography In 56 consecutive patients who underwent multigated radionuclide angiography. Thirteen patients were excluded for the following reasons: 5 for large size of left ventricle required for image acquisition, 5 for suboptimal image quality in realtime 3-dimensional echocardiography, and 3 for atrial fibrillation. Finally, we compared left ventricular ejection fraction assessed by real-time 3-dimensional echocardiography and conventional 2-dimensional echocardiography with that obtained by multigated radionuclide angiography in 43 patients. Left ventricular ejection fraction was determined by real-time 3-dimensional echocardiography with the use of parallel plane-disks and sector plane-disks summation methods. A good correlation was obtained between both real-time 3-dimensional echocardiography methods and multigated radionuclide angiography (r = 0.87 and 0.90, standard error of estimate = 3.7% and 4.2%), whereas the relation between the 2-dimensional echocardiography method and radionuclide angiography demonstrated a significant departure from the line of identity (P <.001). In addition, interobserver variability was significantly lower (P <.05) for the real-time 3-dimensional echocardiography methods than that by the 2-dimensional echocardiography method. Real-time 3-dimensional echocardiography may be used for quantification of left ventricular function as an alternative to conventional methods in patients with adequate image quality.
引用
收藏
页码:275 / 284
页数:10
相关论文
共 41 条
[1]   RESULTS OF CORONARY-ARTERY SURGERY IN PATIENTS WITH POOR LEFT-VENTRICULAR FUNCTION (CASS) [J].
ALDERMAN, EL ;
FISHER, LD ;
LITWIN, P ;
KAISER, GC ;
MYERS, WO ;
MAYNARD, C ;
LEVINE, F ;
SCHLOSS, M .
CIRCULATION, 1983, 68 (04) :785-795
[2]   MEASUREMENT IN MEDICINE - THE ANALYSIS OF METHOD COMPARISON STUDIES [J].
ALTMAN, DG ;
BLAND, JM .
JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES D-THE STATISTICIAN, 1983, 32 (03) :307-317
[3]   COMPARISON OF EARLY TL-201 SCINTIGRAPHY AND GATED BLOOD POOL IMAGING FOR PREDICTING MORTALITY IN PATIENTS WITH ACUTE MYOCARDIAL-INFARCTION [J].
BECKER, LC ;
SILVERMAN, KJ ;
BULKLEY, BH ;
KALLMAN, CH ;
MELLITS, ED ;
WEISFELDT, M .
CIRCULATION, 1983, 67 (06) :1272-1282
[4]   ANALYSIS OF LEFT-VENTRICULAR FUNCTION FROM MULTIPLE GATED ACQUISITION CARDIAC BLOOD POOL IMAGING - COMPARISON TO CONTRAST ANGIOGRAPHY [J].
BUROW, RD ;
STRAUSS, HW ;
SINGLETON, R ;
POND, M ;
REHN, T ;
BAILEY, IK ;
GRIFFITH, LC ;
NICKOLOFF, E ;
PITT, B .
CIRCULATION, 1977, 56 (06) :1024-1028
[5]  
CALLAHAN RJ, 1982, J NUCL MED, V23, P315
[6]   Assessment of regional wall motion abnormalities with real-time 3-dimensional echocardiography [J].
Collins, M ;
Hsieh, A ;
Ohazama, CJ ;
Ota, T ;
Stetten, G ;
Donovan, CL ;
Kisslo, J ;
Ryan, T .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 1999, 12 (01) :7-14
[7]  
FEIGENBAUM H, 1994, ECHOCARDIOGR-J CARD, P117
[8]   ASSESSMENT OF LEFT-VENTRICULAR EJECTION FRACTION AND VOLUMES BY REAL-TIME, 2-DIMENSIONAL ECHOCARDIOGRAPHY - COMPARISON OF CINEANGIOGRAPHIC AND RADIONUCLIDE TECHNIQUES [J].
FOLLAND, ED ;
PARISI, AF ;
MOYNIHAN, PF ;
JONES, DR ;
FELDMAN, CL ;
TOW, DE .
CIRCULATION, 1979, 60 (04) :760-766
[9]   COMPARISON OF LEFT-VENTRICULAR EJECTION FRACTION BY MAGNETIC-RESONANCE-IMAGING AND RADIONUCLIDE VENTRICULOGRAPHY IN IDIOPATHIC DILATED CARDIOMYOPATHY [J].
GAUDIO, C ;
TANZILLI, G ;
MAZZAROTTO, P ;
MOTOLESE, M ;
ROMEO, F ;
MARINO, B ;
REALE, A .
AMERICAN JOURNAL OF CARDIOLOGY, 1991, 67 (05) :411-415
[10]   ASSESSMENT OF CARDIAC-FUNCTION BY 3-DIMENSIONAL ECHOCARDIOGRAPHY COMPARED WITH CONVENTIONAL NONINVASIVE METHODS [J].
GOPAL, AS ;
SHEN, ZQ ;
SAPIN, PM ;
KELLER, AM ;
SCHNELLBAECHER, MJ ;
LEIBOWITZ, DW ;
AKINBOBOYE, OO ;
RODNEY, RA ;
BLOOD, DK ;
KING, DL .
CIRCULATION, 1995, 92 (04) :842-853