RELIABILITY OF PANORAMIC ULTRASOUND IMAGING IN SIMULTANEOUSLY EXAMINING MUSCLE SIZE AND QUALITY OF THE HAMSTRING MUSCLES IN YOUNG, HEALTHY MALES AND FEMALES

被引:62
作者
Palmer, Ty B. [1 ]
Akehi, Kazuma [2 ]
Thiele, Ryan M. [1 ]
Smith, Doug B. [1 ]
Thompson, Brennan J. [3 ]
机构
[1] Oklahoma State Univ, Dept Hlth & Human Performance, Appl Musculoskeletal & Human Physiol Res Lab, Stillwater, OK 74078 USA
[2] Univ Nebraska Kearney, Dept Kinesiol & Sport Sci, Kearney, NE USA
[3] Texas Tech Univ, Dept Hlth Exercise & Sport Sci, Human Performance Lab, Lubbock, TX 79409 USA
关键词
Cross-sectional area; Echo intensity; Muscle thickness; Gender; Biceps femoris; Semitendinosus; Semimembranosus; CROSS-SECTIONAL AREA; SKELETAL-MUSCLE; ECHO INTENSITY; MULTIFIDUS MUSCLE; VASTUS LATERALIS; BODY-COMPOSITION; UNTRAINED WOMEN; PENNATION ANGLE; TIME-COURSE; OLDER MEN;
D O I
10.1016/j.ultrasmedbio.2014.10.011
中图分类号
O42 [声学];
学科分类号
070206 [声学];
摘要
The purpose of this study was to examine the reliability of ultrasound (US) measures of cross-sectional area (CSA), muscle thickness (MT) and echo intensity (EI) of the hamstrings, with comparisons between males and females. In 20 healthy participants (10 males, 10 females), CSA, MT and EI were measured from panoramic US scans of the hamstrings on 2 separate days. The intra-class correlation coefficients and standard errors of measurement as a percentage of the mean for CSA, MT and EI ranged from 0.715 to 0.984 and from 3.145 to 12.541% in the males and from 0.724 to 0.977 and from 4.571 to 17.890% in the females, respectively. The males had greater CSAs and MTs and lower EIs than the females (p = 0.002-0.049), and significant relationships were observed between CSA and MT (r - 50.714-0.938, p <= 0.001-0.023). From an overall reliability standpoint, these findings suggest that panoramic US may be a reliable technique for examining muscle size and quality of the hamstrings in both males and females. (C) 2015 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:675 / 684
页数:10
相关论文
共 61 条
[1]
Abe T, 1997, J Gravit Physiol, V4, pS10
[2]
Abe T., 2005, Int J KAATSU Train Res, V1, P19, DOI 10.3806/ijktr.1.19
[3]
Panoramic ultrasonography is a valid method to measure changes in skeletal muscle cross-sectional area [J].
Ahtiainen, Juha P. ;
Hoffren, Merja ;
Hulmi, Juha J. ;
Pietikainen, Mikko ;
Mero, Antti A. ;
Avela, Janne ;
Hakkinen, Keijo .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2010, 108 (02) :273-279
[4]
NORMAL VALUES FOR QUANTITATIVE MUSCLE ULTRASONOGRAPHY IN ADULTS [J].
Arts, Ilse M. P. ;
Pillen, Sigrid ;
Schelhaas, H. Jurgen ;
Overeem, Sebastiaan ;
Zwarts, Machiel J. .
MUSCLE & NERVE, 2010, 41 (01) :32-41
[5]
CHANGES IN LOWER-LIMB MUSCLE CROSS-SECTIONAL AREA AND TISSUE-FLUID VOLUME AFTER TRANSITION FROM STANDING TO SUPINE [J].
BERG, HE ;
TEDNER, B ;
TESCH, PA .
ACTA PHYSIOLOGICA SCANDINAVICA, 1993, 148 (04) :379-385
[6]
Geometric and architectural contributions to hamstring musculotendinous stiffness [J].
Blackburn, J. Troy ;
Pamukoff, Derek N. .
CLINICAL BIOMECHANICS, 2014, 29 (01) :105-110
[7]
Sex comparison of hamstring structural and material properties [J].
Blackburn, J. Troy ;
Bell, David R. ;
Norcross, Marc F. ;
Hudson, Jeff D. ;
Kimsey, Megan H. .
CLINICAL BIOMECHANICS, 2009, 24 (01) :65-70
[8]
Muscle conduction velocity, strength, neural activity, and morphological changes after eccentric and concentric training [J].
Cadore, E. L. ;
Gonzalez-Izal, M. ;
Pallares, J. G. ;
Rodriguez-Falces, J. ;
Hakkinen, K. ;
Kraemer, W. J. ;
Pinto, R. S. ;
Izquierdo, M. .
SCANDINAVIAN JOURNAL OF MEDICINE & SCIENCE IN SPORTS, 2014, 24 (05) :E343-E352
[9]
Caresio C, 2014, CLIN PHYSL FUNCT IMA
[10]
Muscle damage protection by low-intensity eccentric contractions remains for 2 weeks but not 3 weeks [J].
Chen, Hsin-Lian ;
Nosaka, Kazunori ;
Chen, Trevor C. .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2012, 112 (02) :555-565