Assessment of problems in diagnostic and research immunohistochemistry associated with epitope instability in stored paraffin sections

被引:56
作者
van den Broek, LJCM
van de Vijver, MJ
机构
[1] Leiden Univ, Med Ctr, Dept Pathol, NL-2300 RC Leiden, Netherlands
[2] Netherlands Canc Inst, Dept Pathol, NL-1066 CX Amsterdam, Netherlands
来源
APPLIED IMMUNOHISTOCHEMISTRY & MOLECULAR MORPHOLOGY | 2000年 / 8卷 / 04期
关键词
epitope instability-antigenicity; paraffin sections; immunohistochemistry;
D O I
10.1097/00022744-200012000-00009
中图分类号
R602 [外科病理学、解剖学]; R32 [人体形态学];
学科分类号
100101 ;
摘要
Loss of antigenicity or epitope instability, especially after tissue sections have been prepared, may affect immunohistochemical staining results. To obtain insight into the magnitude of this problem, we conducted a systematic investigation. A total of 20 monoclonal and 12 polyclonal antibodies were used for immunohistochemistry using formalin-fixed, paraffin-embedded sections that were stored for periods ranging from 15 to 360 days at temperatures of 4 degreesC, 21 degreesC, and 37 degreesC. After 1 year of storage, immunohistochemical results appeared to be impaired with four antibodies at 4 degreesC, 11 antibodies at 21 degrees, and 16 antibodies at 37 degreesC. It was found that staining results using polyclonal antisera are affected to the same extent by this phenomenon compared to antibodies of monoclonal origin. No indication was found that antigen retrieval could restore the effect of epitope instability. An additional experiment, in which the influence of section adhesives on epitope instability was investigated, revealed that none of the applied adhesives hampers immunohistochemical reactivity for a storage time of up to 6 months.
引用
收藏
页码:316 / 321
页数:6
相关论文
共 13 条
[1]   Variability of immunohistochemical reactivity on stored paraffin slides [J].
Bertheau, P ;
Cazals-Hatem, D ;
Meignin, V ;
de Roquancourt, A ;
Vérola, O ;
Lesourd, A ;
Séné, C ;
Brocheriou, C ;
Janin, A .
JOURNAL OF CLINICAL PATHOLOGY, 1998, 51 (05) :370-374
[2]   PRESERVATION OF ESTROGEN-RECEPTOR IN PARAFFIN SECTIONS [J].
BROMLEY, CM ;
PALECHEK, PL ;
BENDA, JA .
JOURNAL OF HISTOTECHNOLOGY, 1994, 17 (02) :115-118
[3]   Influence of storage temperature and high-temperature antigen retrieval buffers on results of immunohistochemical staining in sections stored for long periods [J].
Grabau, DA ;
Nielsen, O ;
Hansen, S ;
Nielsen, MM ;
Laenkholm, AV ;
Knoop, A ;
Pfeiffer, P .
APPLIED IMMUNOHISTOCHEMISTRY, 1998, 6 (04) :209-213
[4]  
Hendricks JB, 1996, J HISTOTECHNOL, V19, P23
[5]   Loss of p53-immunostaining intensity in breast cancer [J].
Henson, DE .
JOURNAL OF THE NATIONAL CANCER INSTITUTE, 1996, 88 (15) :1015-1016
[6]   Loss of tumor marker-immunostaining intensity on stored paraffin slides of breast cancer [J].
Jacobs, TW ;
Prioleau, JE ;
Stillman, IE ;
Schnitt, SJ .
JOURNAL OF THE NATIONAL CANCER INSTITUTE, 1996, 88 (15) :1054-1059
[7]  
KATO J, 1995, NEW ENGL J MED, V333, P1507
[8]   P53 ANTIGEN LOSS IN STORED PARAFFIN SLIDES [J].
PRIOLEAU, J ;
SCHNITT, SJ .
NEW ENGLAND JOURNAL OF MEDICINE, 1995, 332 (22) :1521-1522
[9]   ESTROGEN-RECEPTOR STAINING OF PARAFFIN-EMBEDDED BREAST CARCINOMAS FOLLOWING SHORT FIXATION IN FORMALIN - A COMPARISON WITH CYTOSOLIC AND FROZEN SECTION RECEPTOR ANALYSES [J].
RAYMOND, WA ;
LEONG, ASY .
JOURNAL OF PATHOLOGY, 1990, 160 (04) :295-303
[10]  
Shin HJC, 1997, MODERN PATHOL, V10, P224