Synthesis, characterization and applications of pyrocatechol modified amberlite XAD-2 resin for preconcentration and determination of metal ions in water samples by flame atomic absorption spectrometry (FAAS)

被引:174
作者
Tewari, PK [1 ]
Singh, AK [1 ]
机构
[1] Indian Inst Technol, Dept Chem, New Delhi 110016, India
关键词
amberlite XAD-2; atomic absorption spectrometry; chelating resin; extraction; metal ions; pyrocatechol; water analysis;
D O I
10.1016/S0039-9140(00)00572-5
中图分类号
O65 [分析化学];
学科分类号
070302 [分析化学]; 081704 [应用化学];
摘要
A new chelating resin is prepared by coupling Amberlite XAD-2 with pyrocatechol through an azo spacer, characterized (by elemental analysis, IR and TGA) and studied for preconcentrating Cd(II), Co(II), Cu(II), Fe(III), Ni(II) and Zn(II) using flame atomic absorption spectrometry (FAAS) for metal monitoring. The sorption is quantitative in the pH range 3.0-6.5, whereas quantitative desorption occurs instantaneously with 2 M HCl or HNO3 The sorption capacity has been found to be in the range 0.023-0.092 mmol g(-1) of resin. The loading half time (t(1/2)) is 1.4, 4.8, 1.6, 3.2, 2.3 and 1.8 min, respectively for Cd, Co, Cu, Fe, Ni and Zn. The tolerance limits of electrolytes NaCl, NaBr, NaNO3, Na2SO4 and Na3PO4 in the sorption of all the six metal ions (0.2 mug ml(-1)) are reported. The Mg(II) and Ca(II) are tolerable with each of them (0.2 mug ml(-1)) up to a concentration level of 0.01-1.0 M. The enrichment factor has been found to be 200 except for Fe and Cu for which the values are 80 and 100, respectively. The lowest concentration of metal ion for quantitative recovery is 5, 10, 20, 25, 10 and 10 mug l(-1) for Cd, Co, Cu, Fe, Ni and Zn, respectively. The simultaneous determination of all these metal ions is possible and the method has been applied to determine all the six metal ions in tap and river water samples (RSD 13.9 and 7.3%, respectively). The cobalt content of pharmaceutical vitamin tablets is estimated by FAAS (RSD similar to 2%) after its preconcentration with the present chelating resin. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:823 / 833
页数:11
相关论文
共 45 条
[1]
Determination of metals in highly saline matrices by solid-phase extraction and slurry-sampling inductively coupled plasma-atomic emission spectrometry [J].
Abollino, O ;
Aceto, M ;
Bruzzoniti, MC ;
Mentasti, E ;
Sarzanini, C .
ANALYTICA CHIMICA ACTA, 1998, 375 (03) :293-298
[2]
Effect of salicylic acid upon trace-metal sorption (CdII, ZnII, CoII, and MnII) onto alumina, silica, and kaolinite as a function of pH [J].
Benyahya, L ;
Garnier, JM .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1999, 33 (09) :1398-1407
[3]
Bilba D, 1998, CROAT CHEM ACTA, V71, P155
[4]
Selective determination of cobalt using polyurethane foam and 2-(2-benzothiazolylazo)-2-p-cresol as a spectrophotometric reagent [J].
Carvalho, MS ;
Fraga, ICS ;
Neto, KCM ;
Silva, EQ .
TALANTA, 1996, 43 (10) :1675-1680
[5]
SYNTHESIS AND EFFICIENCY OF A POLYACRYLACYLISOTHIOUREA CHELATING FIBER FOR THE PRECONCENTRATION AND SEPARATION OF TRACE AMOUNTS OF GOLD, PALLADIUM AND RUTHENIUM FROM SOLUTION SAMPLES [J].
CHANG, XJ ;
SU, ZX ;
ZHAN, GY ;
LUO, XY ;
GAO, WY .
ANALYST, 1994, 119 (07) :1445-1449
[6]
SPECTROFLUOROMETRIC DETECTION-OF ZINC AND CADMIUM WITH 8-(BENZENESULFONAMIDO)-QUINOLINE IMMOBILIZED ON A POLYMERIC MATRIX [J].
COMPANO, R ;
FERRER, R ;
GUITERAS, J ;
PRAT, MD .
ANALYST, 1994, 119 (06) :1225-1228
[7]
Synthetic zeolites as sorbent material for on-line preconcentration of copper traces and its determination using flame atomic absorption spectrometry [J].
de Peña, YP ;
López, W ;
Burguera, JL ;
Burguera, M ;
Gallignani, M ;
Brunetto, R ;
Carrero, P ;
Rondon, C ;
Imbert, F .
ANALYTICA CHIMICA ACTA, 2000, 403 (1-2) :249-258
[8]
Poly(amidoamine) dendrimers: A new class of high capacity chelating agents for Cu(II) ions [J].
Diallo, MS ;
Balogh, L ;
Shafagati, A ;
Johnson, JH ;
Goddard, WA ;
Tomalia, DA .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1999, 33 (05) :820-824
[9]
Erk Ç, 1999, MIKROCHIM ACTA, V132, P79
[10]
Copper determination in natural water samples by using FAAS after preconcentration onto amberlite XAD-2 loaded with calmagite [J].
Ferreira, SLC ;
Ferreira, JR ;
Dantas, AF ;
Lemos, VA ;
Araújo, NML ;
Costa, ACS .
TALANTA, 2000, 50 (06) :1253-1259