Three-dimensional computational fluid dynamics modeling of alterations in coronary wall shear stress produced by stent implantation

被引:146
作者
LaDisa, JF
Guler, I
Olson, LE
Hettrick, DA
Kersten, JR
Warltier, DC
Pagel, PS
机构
[1] Med Coll Wisconsin, Dept Anesthesiol, Milwaukee, WI 53226 USA
[2] Med Coll Wisconsin, Dept Med, Div Cardiovasc Dis, Milwaukee, WI 53226 USA
[3] Med Coll Wisconsin, Dept Pharmacol & Toxicol, Milwaukee, WI 53226 USA
[4] Clement J Zablocki Vet Affairs Med Ctr, Milwaukee, WI USA
[5] Marquette Univ, Dept Biomed Engn, Milwaukee, WI 53233 USA
[6] Boston Sci Scimed, Maple Grove, MN USA
关键词
shear stress; coronary hemodynamics; slotted-tube endovascular stents; vascular prosthesis; coronary artery disease; numerical modeling; intimal hyperplasia; restenosis;
D O I
10.1114/1.1588654
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Rates of coronary restenosis after stent implantation vary with stent design. Recent evidence suggests that alterations in wall shear stress associated with different stent types and changes in local vessel geometry after implantation may account for this disparity. We tested the hypothesis that wall shear stress is altered in a three-dimensional computational fluid dynamics (CFD) model after coronary implantation of a 16 mm slotted-tube stent during simulations of resting blood flow and maximal vasodilation. Canine left anterior descending coronary artery blood flow velocity and interior diameter were used to construct CFD models and evaluate wall shear stress proximal and distal to and within the stented region. Channeling of adjacent blood layers due to stent geometry had a profound affect on wall shear stress. Stagnation zones were localized around stent struts. Minimum wall shear stress decreased by 77% in stented compared to unstented vessels. Regions of low wall shear stress were extended at the stent outlet and localized to regions where adjacent axial strut spacing was minimized and the circumferential distance between struts was greatest within the stent. The present results depict alterations in wall shear stress caused by a slotted-tube stent and support the hypothesis that stent geometry may be a risk factor for restenosis by affecting local wall shear stress distributions. (C) 2003 Biomedical Engineering Society.
引用
收藏
页码:972 / 980
页数:9
相关论文
共 42 条
[1]  
[Anonymous], J VASC INVEST
[2]   CHANGES IN ARTERIAL-WALL COMPLIANCE AFTER ENDOVASCULAR STENTING [J].
BACK, M ;
KOPCHOK, G ;
MUELLER, M ;
CAVAYE, D ;
DONAYRE, C ;
WHITE, RA .
JOURNAL OF VASCULAR SURGERY, 1994, 19 (05) :905-911
[3]   Experimental and computational flow evaluation of coronary stents [J].
Berry, JL ;
Santamarina, A ;
Moore, JE ;
Roychowdhury, S ;
Routh, WD .
ANNALS OF BIOMEDICAL ENGINEERING, 2000, 28 (04) :386-398
[4]   Long-term endothelial dysfunction after coronary artery stenting [J].
Caramori, PRA ;
Lima, VC ;
Seidelin, PH ;
Newton, GE ;
Parker, JD ;
Adelman, AG .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1999, 34 (06) :1675-1679
[5]   VASCULAR ENDOTHELIUM RESPONDS TO FLUID SHEAR-STRESS GRADIENTS [J].
DEPAOLA, N ;
GIMBRONE, MA ;
DAVIES, PF ;
DEWEY, CF .
ARTERIOSCLEROSIS AND THROMBOSIS, 1992, 12 (11) :1254-1257
[6]  
Dyke M. V., 1982, ALBUM FLUID MOTION
[7]   Pathobiologic responses to stenting [J].
Edelman, ER ;
Rogers, C .
AMERICAN JOURNAL OF CARDIOLOGY, 1998, 81 (7A) :4E-6E
[8]   Coronary-artery stenting compared with balloon angioplasty for restenosis after initial balloon angioplasty [J].
Erbel, R ;
Haude, M ;
Höpp, HW ;
Franzen, D ;
Rupprecht, HJ ;
Heublein, B ;
Fischer, K ;
De Jaegere, P ;
Serruys, P ;
Rutsch, W ;
Probst, P .
NEW ENGLAND JOURNAL OF MEDICINE, 1998, 339 (23) :1672-1678
[9]   A RANDOMIZED COMPARISON OF CORONARY-STENT PLACEMENT AND BALLOON ANGIOPLASTY IN THE TREATMENT OF CORONARY-ARTERY DISEASE [J].
FISCHMAN, DL ;
LEON, MB ;
BAIM, DS ;
SCHATZ, RA ;
SAVAGE, MP ;
PENN, I ;
DETRE, K ;
VELTRI, L ;
RICCI, D ;
NOBUYOSHI, M ;
CLEMAN, M ;
HEUSER, R ;
ALMOND, D ;
TEIRSTEIN, PS ;
FISH, RD ;
COLOMBO, A ;
BRINKER, J ;
MOSES, J ;
SHAKNOVICH, A ;
HIRSHFELD, J ;
BAILEY, S ;
ELLIS, S ;
RAKE, R ;
GOLDBERG, S .
NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (08) :496-501
[10]   STRENGTH, ELASTICITY, AND PLASTICITY OF EXPANDABLE METAL STENTS - IN-VITRO STUDIES WITH 3 TYPES OF STRESS [J].
FLUECKIGER, F ;
STERNTHAL, H ;
KLEIN, GE ;
ASCHAUER, M ;
SZOLAR, D ;
KLEINHAPPL, G .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1994, 5 (05) :745-750