Prediction of lubricating film thickness in UHMWPE hip joint replacements

被引:88
作者
Jalali-Vahid, D
Jagatia, M
Jin, ZM [1 ]
Dowson, D
机构
[1] Univ Bradford, Dept Mech & Med Engn, Bradford DB7 1DP, W Yorkshire, England
[2] Univ Leeds, Sch Mech Engn, Leeds LS2 9JT, W Yorkshire, England
基金
英国工程与自然科学研究理事会;
关键词
elastohydrodynamic lubrication; artificial hip joint replacements; UHMWPE;
D O I
10.1016/S0021-9290(00)00181-0
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
An elastohydrodynamic lubrication model developed for a ball-in-socket configuration in a previous studies by the present authors (Jalali-Vahid et al., Thinning films and tribological interfaces, 26th Leeds-Lyon Symposium on Tribology, 2000, pp. 329-339) was applied to analyse the lubrication problem of a typical artificial hip joint replacement, consisting of an ultra-high molecular weight polyethylene (UMMWPE) acetabular cup against a metallic or ceramic femoral head. The cup was assumed to be stationary whilst the ball was assumed to rotate at a steady angular velocity and under a constant load. A wide range of main design parameters were considered. it has been found that the predicted lubricating film thickness increases with a decrease in the radial clearance, an increase in the femoral head radius, an increase in UHMWPE thickness and a decrease in UHMWPE modulus. However, the predicted lubricating film thicknesses are not found to be sufficiently large in relation to the surface roughness of the cup and head to indicate separation of the two articulating surfaces. it should also be noted that if the design features are unable to secure full fluid film lubrication, it may be preferable to select them for minimum wear rather than maximum film thickness. For example, an increase in head radius will enhance the film thickness, but it will also increase the sliding distance and hence wear in mixed or boundary lubrication conditions. Furthermore, it is pointed out that an increase in the predicted lubricant film thickness is usually associated with an increase in the contact area, and this may cause lubricant starvation and stress concentration at the edge of the cup, and adversely affect the tribological performance of the implant. The effect of running-in process on the lubrication in UHMWPE hip joint replacements is also discussed. (C) 2001 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:261 / 266
页数:6
相关论文
共 24 条
[1]  
AI C, 1996, TRIBOL T, V39, P103
[2]  
AMSTUTZ HC, 1991, CLIN ORTHOP RELAT R, V276, P7
[3]  
CHAN FW, 1999, CLIN ORTHOP RELAT R, V369, P10
[4]   Surface topography of retrieved PCA acetabular liners: proposal of a novel wear mechanism [J].
Elfick, AP ;
Hall, RM ;
Unsworth, A ;
Pinder, IM .
JOURNAL OF MATERIALS SCIENCE LETTERS, 1998, 17 (13) :1085-1088
[5]  
Fisher J, 1992, J ENG MED, V205
[6]   ELASTOHYDRODYNAMIC LUBRICATION OF ELLIPTICAL CONTACTS FOR MATERIALS OF LOW ELASTIC-MODULUS I - FULLY FLOODED CONJUNCTION [J].
HAMROCK, BJ ;
DOWSON, D .
JOURNAL OF LUBRICATION TECHNOLOGY-TRANSACTIONS OF THE ASME, 1978, 100 (02) :236-245
[7]   Biological reactions to wear debris in total joint replacement [J].
Ingham, E ;
Fisher, J .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2000, 214 (H1) :21-37
[8]  
JASTY M, 1992, Current Opinion in Rheumatology, V4, P204, DOI 10.1097/00002281-199204000-00012
[9]  
Jin Z., 2000, THINNING FILMS TRIBO, P329
[10]   A PARAMETRIC ANALYSIS OF THE CONTACT STRESS IN ULTRA-HIGH-MOLECULAR-WEIGHT POLYETHYLENE ACETABULAR CUPS [J].
JIN, ZM ;
DOWSON, D ;
FISHER, J .
MEDICAL ENGINEERING & PHYSICS, 1994, 16 (05) :398-405