Developing a parametric ear model for auricular reconstruction: A new step towards patient-specific implants

被引:44
作者
Bos, E. J. [1 ,2 ]
Scholten, T. [3 ]
Song, Y. [3 ]
Verlinden, J. C. [3 ]
Wolff, J. [4 ]
Forouzanfar, T. [4 ]
Helder, M. N. [5 ]
van Zuijlen, P. [1 ,2 ]
机构
[1] Vrije Univ Amsterdam Med Ctr, Dept Plast & Reconstruct Surg, Amsterdam, Netherlands
[2] Burn Ctr Beverwijk, Beverwijk, Netherlands
[3] Delft Univ Technol, Fac Ind Design Engn, Delft, Netherlands
[4] Vrije Univ Amsterdam Med Ctr, Dept Oral & Maxillofacial Surg, Amsterdam, Netherlands
[5] Vrije Univ Amsterdam Med Ctr, Dept Orthoped, Amsterdam, Netherlands
关键词
Reconstruction; Ear; Parametric; Personalized; Model; Implant; CARTILAGE; AURICLE; CELL;
D O I
10.1016/j.jcms.2014.12.016
中图分类号
R78 [口腔科学];
学科分类号
100302 [口腔临床医学];
摘要
Introduction: Ear reconstruction is a tedious and demanding surgical procedure and the implant framework used is essential for the esthetic result. The outcome of a reconstructed ear, however, is not necessarily limited to the implant shape but rather to the available options of transplantable tissue for coverage. Apart from the visual aesthetics, ear reconstruction subsequently also requires implant dimensions to be adapted to the surgical possibilities. In this article, we have brought different disciplines together to develop a customizable ear model for 3D printing of ear implants. Material and methods: Computed tomography (CT) scans were made of 4 human cadaver ears before and after soft tissue dissection using a Discovery 750 High Definition Freedom Edition scanner (GE, Milwaukee, WI, USA) and subsequently converted into an STL data set using Mimics Software (Materialise, Leuven, Belgium). These scans were then used to develop a fully adjustable parametric model based on the essential ear anatomy using Rhinoceros and Grasshopper software. Results: To determine the quality of the developed models, directed Hausdorff distance (DHD) was applied as the basis for measuring the similarity between the parametric model and the ear cartilage scanning data. Two methods were used. The mean directed Haussdorff distance (MDHD) was calculated based on the distribution of point sets showing an average similarity of 0.8 mm (+/- 0.05 mm). The mean similarity coefficient (SC) of the model and scan surfaces was 94% with a 2-mm threshold. Conclusion: This study shows that a parametric standard model could be used as a feasible method to generate custom implants based on existing ear images. (C) 2015 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:390 / 395
页数:6
相关论文
共 26 条
[1]
Burned ear reconstruction using a prefabricated free radial forearm flap [J].
Akin, S .
JOURNAL OF RECONSTRUCTIVE MICROSURGERY, 2001, 17 (04) :233-236
[2]
Berghaus A, 2010, ADV OTO-RHINO-LARYNG, V68, P53, DOI 10.1159/000314562
[3]
Total ear reconstruction in post burn deformity [J].
Bhandari, PS .
BURNS, 1998, 24 (07) :661-670
[4]
Auricular Reconstruction with Porous Polyethylene Frameworks: Outcome and Patient Benefit in 65 Children and Adults [J].
Braun, Thomas ;
Gratza, Sonja ;
Becker, Sven ;
Schwentner, Ilona ;
Stelter, Klaus ;
Patscheider, Martin ;
Berghaus, Alexander ;
Hempel, John Martin .
PLASTIC AND RECONSTRUCTIVE SURGERY, 2010, 126 (04) :1201-1212
[6]
[7]
Coward TJ, 2000, INT J ORAL MAX SURG, V29, P18
[8]
Coward TJ, 2007, INT J PROSTHODONT, V20, P275
[9]
Prosthesis Auricular With Osseointegrated Implants and Quality of Life [J].
dos Santos, Daniela Micheline ;
Goiato, Marcelo Coelho ;
Pesqueira, Aldieres Alves ;
Bannwart, Lisiane Cristina ;
Rosifini Alves Rezende, Maria Cristina ;
Magro-Filho, Osvaldo ;
Moreno, Amalia .
JOURNAL OF CRANIOFACIAL SURGERY, 2010, 21 (01) :94-96
[10]
Combining Scalp Tissue Expansion With Porous Polyethylene Total Ear Reconstruction in Burned Patients [J].
Driscoll, Daniel N. ;
Lee, Jeffrey H. .
ANNALS OF PLASTIC SURGERY, 2010, 64 (02) :183-186